As defined in RFC 2328, all non-backbone areas must maintain connectivity to the backbone. You can
use the vlink-peer command to configure a virtual link to connect an area to the backbone.
Considerations on parameters:
The smaller the hello interval is, the faster the network converges and the more network resources
are consumed.
A so small retransmission interval will lead to unnecessary retransmissions. A big value is
appropriate for a low speed link.
You must specify an appropriate transmission delay with the trans-delay keyword.
The authentication mode at the non-backbone virtual link end follows the one at the backbone virtual link
end. The two authentication modes (MD5 or Simple) are independent, and you can specify neither of
them.
Related commands: authentication-mode, display ospf.
Examples
# C o n f i g u r e a v i r t u a l l i n k t o t h e n e i g h b o r w i t h r o u t e r I D 1.1.1.1.
<Sysname> system-view
[Sysname] ospf 100
[Sysname-ospf-100] area 2
[Sysname-ospf-100-area-0.0.0.2] vlink-peer 1.1.1.1