R3166-R3206-HP High-End Firewalls System Management and Maintenance Command Reference-6PW101
123
Field Descri
p
tion
Sampling interval
Sampling interval, in seconds. The system performs absolute sample or delta sample
to sampling variables according to the sampling interval.
Rising threshold
Alarm rising threshold. An event is triggered when the sampled value is greater than
or equal to this threshold.
Falling threshold
Alarm falling threshold. An event is triggered when the sampled value is less than or
equal to this threshold.
linked with event Event index associated with the prialarm
When startup enables How can an alarm be triggered
This entry will exist The lifetime of the entry, which can be forever or span the specified period
Latest value The count result of the last sample
display rmon statistics
Syntax
display rmon statistics [ interface-type interface-number ]
View
Any view
Default level
1: Monitor level
Parameters
interface-type interface-number: Specifies an interface by its type and number.
Description
Use the display rmon statistics command to display RMON statistics.
This command displays the interface statistics during the period from the time the statistics entry is created
to the time the command is executed. The statistics are cleared after the device reboots.
Related commands: rmon statistics.
Examples
# Display RMON statistics for interface GigabitEthernet 0/1.
<Sysname> display rmon statistics gigabitethernet 0/1
EtherStatsEntry 1 owned by null is VALID.
Interface : GigabitEthernet0/1<ifIndex.3>
etherStatsOctets : 43393306 , etherStatsPkts : 619825
etherStatsBroadcastPkts : 503581 , etherStatsMulticastPkts : 44013
etherStatsUndersizePkts : 0 , etherStatsOversizePkts : 0
etherStatsFragments : 0 , etherStatsJabbers : 0
etherStatsCRCAlignErrors : 0 , etherStatsCollisions : 0
etherStatsDropEvents (insufficient resources): 0
Packets received according to length:
64 : 0 , 65-127 : 0 , 128-255 : 0
256-511: 0 , 512-1023: 0 , 1024-1518: 0