125
Field Descri
p
tion
Packets received according to length:
64 : 0 , 65-127 : 0 ,
128-255 : 0
256-511: 0 , 512-1023:
0 , 1024-1518: 0
Statistics of packets received according to length during the statistical
period (Hardware support is needed for the statistics. If the hardware
does not support the function, all statistics are displayed as 0.), in
which:
Information of the field 64 corresponds to the MIB node
etherStatsPkts64Octets
Information of the field 65-127 corresponds to the MIB node
etherStatsPkts65to127Octets
Information of the field 128-255 corresponds to the MIB node
etherStatsPkts128to255Octets
Information of the field 256-511 corresponds to the MIB node
etherStatsPkts256to511Octets
Information of the field 512-1023 corresponds to the MIB node
etherStatsPkts512to1023Octets
Information of the field 1024-1518 corresponds to the MIB node
etherStatsPkts1024to1518Octets
rmon alarm
Syntax
rmon alarm entry-number alarm-variable sampling-interval { absolute | delta } rising-threshold
threshold-value1 event-entry1 falling-threshold threshold-value2 event-entry2 [ owner text ]
undo rmon alarm entry-number
View
System view
Default level
2: System level
Parameters
entry-number: Alarm entry index, in the range 1 to 65535.
alarm-variable: Alarm variable, a string of 1 to 256 characters. It can be in dotted object identifier (OID)
format (in the format of entry.integer.instance or leaf node name.instance, for example,
1.3. 6 .1. 2.1. 2.1.10 .1) , o r a n o d e n a m e l i k e i f I n O c t e t s .1. Only variables that can be parsed into INTEGER
(INTEGER, Counter, Gauge, or Time Ticks) in the ASN.1 can be used for the alarm-variable argument,
such as the instance of the leaf node (like etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, and
so on) of the etherStatsEntry entry, the instance of the leaf node (like ifInOctets, ifInUcastPkts,
ifInNUcastPkts, and so on) of the ifEntry entry.
sampling-interval: Sampling interval, in the range 5 to 65,535 seconds.
absolute: Sets the sampling type to absolute, namely, the system obtains the value of the variable when
the sampling time is reached.
delta: Sets the sampling type to delta, namely, the system obtains the variation value of the variable
during the sampling interval when the sampling time is reached.
rising-threshold threshold-value1 event-entry1: Sets the rising threshold, where threshold-value1
represents the rising threshold, in the range –2,147,483,648 to +2,147,483,647, and event-entry1