variable is smaller than or equal to the lower threshold, a lower event is triggered. The event is then
handled as defined in the event group.
NOTE:
If the value of a sampled alarm variable overpasses the same threshold multiple times, only the first one
can cause an alarm event. That is, the rising alarm and falling alarm are alternate.
Private alarm group
The private alarm group calculates the values of alarm variables and compares the result with the defined
threshold, thereby realizing a more comprehensive alarming function.
System handles the prialarm alarm table entry (as defined by the user) in the following ways:
• Periodically samples the prialarm alarm variables defined in the prialarm formula.
• Calculates the sampled values based on the prialarm formula.
• Compares the result with the defined threshold and generates an appropriate event.
NOTE:
If the count result overpasses the same threshold multiple times, only the first one can cause an alarm
event. That is, the rising alarm and falling alarm are alternate.
Configuring the RMON statistics function
RMON statistics function can be implemented by either the Ethernet statistics group or the history group,
but the objects of the statistics are different, you can choose to configure a statistics group or a history
group accordingly.
• A statistics object of the Ethernet statistics group is a variable defined in the Ethernet statistics table,
and the recorded content is a cumulative sum of the variable from the time the statistics entry is
created to the current time. For more information, see “Configuring the RMON Ethernet statistics
fu
nction.”
• A statistics object of the history group is the variable defined in the history record table, and the
recorded content is a cumulative sum of the variable in each period. For more information, see
“Configuring the RMON history statistics function.”
Configuring the RMON Ethernet statistics function
Follow these steps to configure the RMON Ethernet statistics function:
To do… Use the command…
Remarks
Enter system view system-view —
Enter Ethernet interface view interface interface-type interface-number —
Create an entry in the RMON statistics table
rmon statistics entry-number [ owner text ] Required
NOTE:
• Only one statistics entry can be created on one interface.