R3204P16-HP Load Balancing Module High Availability Configuration Guide-6PW101

47
Configuring stateful failover
Select High Availability > Stateful Failover from the navigation tree to enter the stateful failover
configuration page, as shown in Figure 29. T
he upper part of the page allows you to configure stateful
failover parameters. The lower part of the page displays the current stateful failover configuration and the
failover interface information.
Figure 29 Stateful failover configuration page
Table 8 Stateful failover configuration items
Item Descri
p
tion
Enable Stateful Failover Enable/disable the stateful failover feature.
Backup Type
Select whether to support asymmetric path.
Unsupport Asymmetric Path. When two devices operate properly, traffic passes
through one device to the internal network and goes out through the same
device. The devices work in the master/backup mode, that is, one device
processes services while the other device serves as backup.
Support Asymmetric Path. When two devices operate properly, traffic can pass
through one device to the internal network and go out through the other device.
That is, the session passes through one of the two devices randomly when
leaving the internal network, thus to achieve load sharing. The two devices
work in the load sharing mode and serve as backup for each other.
Backup Interface
Set failover interfaces and specify the working mode (electrical or optical interface
mode) for the currently effective failover interfaces.
Click Modify Backup Interface to enter the Backup Interface Configuration page,
and then you can:
Select one or more interfaces from the Optional Backup Interface(s) list, and
then click the << button to add the selected interfaces to the Backup Interface(s)
list.
Select one or more interfaces from the Backup Interface(s) list, and then click
the >> button to remove the selected interfaces from the list.
Modify the working mode of any failover interface in the list at the lower part.
All currently effective failover interfaces are displayed in the list. If no failover
interface is specified, the list is not displayed.
After completing the settings, click Apply to return to the stateful failover
configuration page.