R3204P16-HP Load Balancing Module System Management Command Reference-6PW101

36
[Sysname] acsei server enable
acsei timer clock-sync
Syntax
acsei timer clock-sync minutes
undo acsei timer clock-sync
View
ACSEI server view
Default level
2: System level
Parameters
minutes: Value of the synchronization timer that is used for clock synchronization from ACSEI server to
ACSEI client. It ranges from 0 to 1440 (in minutes), where value 0 specifies to disable the clock
synchronization from ACSEI server to ACSEI client.
Description
Use the acsei timer clock-sync command to set the synchronization timer that is used for clock
synchronization from ACSEI server to ACSEI client.
Use the undo acsei timer clock-sync command to restore the default.
By default, the clock sychronization timer is set to five minutes.
Examples
# Set the clock synchronization timer from ACSEI server to ACSEI client to 20 minutes.
<Sysname> system-view
[Sysname] acsei server
[Sysname-acsei-server] acsei timer clock-sync 20
acsei timer monitor
Syntax
acsei timer monitor seconds
undo acsei timer monitor
View
ACSEI server view
Default level
2: System level
Parameters
seconds: Value of the monitoring timer that is used for ACSEI server to monitor ACSEI clients. It ranges
from 0 to 10 (in seconds), where 0 specifies to disable ACSEI server from monitoring ACSEI client.
Description
Use the acsei timer monitor command to set the monitoring timer for ACSEI server to monitor ACSEI
client.