NTP configuration commands
display ntp-service sessions
Syntax
display ntp-service sessions [ verbose ]
View
Any view
Default level
1: Monitor level
Parameters
verbose: Displays detailed information about all NTP sessions. If you do not specify this keyword, only
the brief information about the NTP sessions is displayed.
Description
Use the display ntp-service sessions command to view information about all NTP sessions.
Examples
# View the brief information of all NTP sessions.
<Sysname> display ntp-service sessions
source reference stra reach poll now offset delay disper
********************************************************************************
[12345]127.127.1.0 127.127.1.0 3 1 64 33 0.0 0.0 0.0
note: 1 source(master),2 source(peer),3 selected,4 candidate,5 configured
Total associations : 1
Table 18 Output description
Field Descri
p
tion
source IP address of the clock source
reference
Reference clock ID of the clock source
1. If the reference clock is the local clock, the value of this field is related to the value
of the stra field:
• When the value of the stra field is 0 or 1, this field will be “LOCL”;
• When the stra field has another value, this field will be the IP address of the local
clock.
2. If the reference clock is the clock of another device on the network, the value of
this field will be the IP address of that device.
stra
Stratum level of the clock source, which determines the clock precision. The value
ranges from 1 to 16. The clock precision decreases from stratum 1 to stratum 16. A
stratum 1 clock has the highest precision, and a stratum 16 clock is not synchronized
and cannot be used as a reference clock.
reach
Reachability count of the clock source. 0 indicates that the clock source in
unreachable.