19
To do…
Use the
command…
Remarks
Configure
console
port
properties
Configure the
baud rate
speed speed-value
Optional
By default, the transmission rate is 9600 bps.
Transmission rate is the number of bits that the
device transmits to the terminal per second.
Configure the
parity check mode
parity { even | mark
| none | odd |
space }
Optional
none by default.
Configure the stop
bits
stopbits { 1 | 1.5 | 2 }
Optional
By default, the stop bits of the console port is 1.
Stop bits are the last bits transmitted in data
transmission to unequivocally indicate the end of a
character. The more the bits are, the slower the
transmission is.
Configure the data
bits
databits { 5 | 6 | 7 |
8 }
Optional
By default, the data bits of the console port is 8.
Data bits is the number of bits representing one
character. The setting depends on the contexts to
be transmitted. For example, you can set it to 7 if
standard ASCII characters are to be sent, and set it
to 8 if extended ASCII characters are to be sent.
Define a shortcut
key for enabling a
terminal session
activation-key
character
Optional
By default, you can press Enter to enable a
terminal session.
Define a shortcut
key for terminating
tasks
escape-key { default
| character }
Optional
By default, you can press Ctrl+C to terminate a
task.
Configure stop bits
detection
stopbit-error
intolerance
Optional
By default, no stop bits are detected.
Configure the flow
control mode
flow-control none
Optional
By default, no flow control is performed.
Configure the type
of terminal display
terminal type { ansi |
vt100 }
Optional
By default, the terminal display type is ANSI.
The device supports two types of terminal display:
ANSI and VT100. HP recommends you to set the
display type of both the device and the client to
VT100. If the device and the client use different
display types (for example, hyper terminal or
Telnet terminal) or both are set to ANSI, when the
total number of characters of the currently edited
command line exceeds 80, an anomaly such as
cursor corruption or abnormal display of the
terminal display may occur on the client.
Configure the user
privilege level for
login users
user privilege level
level
Optional
By default, the default command level is 3 for the
console user interface.