R3204P16-HP Load Balancing Module System Management Configuration Guide-6PW101

49
To do… Use the command…
Remarks
Close the specified ACSEI client acsei client close client-id
Optional
Supported on the ACSEI client
running Linux only
Restart the specified ACSEI client acsei client reboot client-id Optional
Configuring ACSEI client on the LB module
Follow these steps to configure the ACSEI client:
To do… Use the command…
Remarks
Enter system view system-view
Enter interface view
interface interface-type
interface-number
Required
Enable the ACSEI client acsei-client enable
Disabled by default.
NOTE:
The Comware platform can run only one ACSEI
client. ACSEI client can be enabled on only one
interface at a time. However, the ACSEI client on
the Comware platform and that on the LB module
can run simultaneously.
Displaying and maintaining ACSEI server and client
To do… Use the command…
Remarks
On the network
device
Display ACSEI client summary
display acsei client summary
[ client-id ]
Available in
any view
Display ACSEI client information
display acsei client info [ client-id ]
On the LB
module
Display ACSEI client information
display acsei-client information
Display current ACSEI client state
display acsei-client status
Example for monitoring and managing the LB
module from the network device
Network requirements
An LB module is installed in slot 3 of the network device to detect the traffic passing the network device.
The internal interface Ten-GigabitEthernet 3/0/1 on the network device is connected to the internal
interface Ten-GigabitEthernet0/0 on the LB module.
When the traffic arrives at the network device, the network device redirects it to the LB module. The LB
module processes the traffic based on the configured policy, and then redirects the traffic that passes the
detection to the network device for forwarding.
Configure the network device and LB module so that you can log in to and restart the LB module from the
network device. Configure the clock synchronization timer from the network device to the LB module as
10 minutes, and configure the monitoring timer as 10 seconds.