Figure 33 Network time
Table 6 Network time configuration items
Item Descri
p
tion
Clock status Displays the synchronization status of the system clock.
Local Reference Source
Set the IP address of the local clock source to 127.127.1.u, where
u ranges from 0 to 3, representing the NTP process ID.
If the IP address of the local clock source is specified, the local
clock is used as the reference clock, and thus can provide time
for other devices.
If the IP address of the local clock source is not specified, the
local clock is not used as the reference clock.
Stratum
Set the stratum level of the local clock.
The stratum level of the local clock decides the precision of the
local clock. A higher value indicates a lower precision. A stratum 1
clock has the highest precision, and a stratum 16 clock is not
synchronized and cannot be used as a reference clock.
Source Interface
Set the source interface for an NTP message.
If you do not want the IP address of a certain interface on the local
LB module to become the destination address of response
messages, you can specify the source interface for NTP messages,
so that the source IP address in the NTP messages is the primary IP
address of this interface. If the specified source interface is down,
the source IP address of the NTP messages sent is the primary IP
address of the outbound interface.