R3204P16-HP Load Balancing Module System Management Configuration Guide-6PW101

61
Table 7 System clock configuration
Item Descri
p
tion Remarks
1 date-time
Configure: clock datetime 1:00 2007/1/1
System clock configured: 01:00:00 UTC Mon
01/01/2007
2 The original system clock ± “zone-offset
Configure: clock timezone zone-time add 1
System clock configured: 02:00:00 zone-time Sat
01/01/2005
1 and 2 date-time ± zone-offset
Configure: clock datetime 2:00 2007/2/2 and
clock timezone zone-time add 1
System clock configured: 03:00:00 zone-time Fri
02/02/2007
[1], 2 and 1 date-time
Configure: clock timezone zone-time add 1 and
clock datetime 3:00 2007/3/3
System clock configured: 03:00:00 zone-time Sat
03/03/2007
3
If the original system clock is not in the
daylight saving time range, the system
clock configured is the original system
clock.
Configure: clock summer-time ss one-off 1:00
2006/1/1 1:00 2006/8/8 2
System clock configured: 01:00:00 UTC Sat
01/01/2005
If the original system clock is in the
daylight saving time range, the system
clock configured is the original system
clock + “summer-offset”.
Configure: clock summer-time ss one-off 00:30
2005/1/1 1:00 2005/8/8 2
System clock configured: 03:00:00 ss Sat
01/01/2005
If the original system clock + “summer-offset” is not
in the daylight saving time range, the system clock
configured is the original system clock. After this
configuration, if you disable the daylight saving,
the system clock becomes the system clock minus
summer-offset”.
1 and 3
If “date-time” is not in the daylight saving
time range, the system clock configured is
date-time”.
Configure: clock datetime 1:00 2007/1/1 and
clock summer-time ss one-off 1:00 2006/1/1
1:00 2006/8/8 2
System clock configured: 01:00:00 UTC Mon
01/01/2007