R3204P16-HP Load Balancing Module System Management Configuration Guide-6PW101
62
Item Descri
p
tion Remarks
If “date-time” is in the daylight saving time
range, the system clock configured is
“date-time” + “summer-offset”.
Configure: clock datetime 8:00 2007/1/1 and
clock summer-time ss one-off 1:00 2007/1/1
1:00 2007/8/8 2
System clock configured: 10:00:00 ss Mon
01/01/2007
If “date-time” + “summer-offset”.is not in the
daylight saving time range, the system clock
configured is “date-time”. After this configuration,
if you disable the daylight saving, the system clock
becomes the system clock minus “summer-offset”.
[1], 3 and 1
If “date-time” is not in the daylight saving
time range, the system clock configured is
“date-time”.
Configure: clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2 and clock datetime
1:00 2008/1/1
System clock configured: 01:00:00 UTC Tue
01/01/2008
“date-time” is in the daylight saving time
range:
If the value of “date-time” -
“summer-offset” is not in the summer-time
range, the system clock configured is
“date-time” - “summer-offset”;
If the value of “date-time” -
“summer-offset” is in the summer-time
range, the system clock configured is
“date-time”.
Configure: clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2 and clock datetime
1:30 2007/1/1
System clock configured: 23:30:00 UTC Sun
12/31/2006
Configure: clock summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2 and clock datetime
3:00 2007/1/1
System clock configured: 03:00:00 ss Mon
01/01/2007
2 and 3 or 3
and 2
If the value of the original system clock ±
“zone-offset” is not in the summer-time
range, the system clock configured is the
original system clock ± “zone-offset”.
Configure: clock timezone zone-time add 1 and
clock summer-time ss one-off 1:00 2007/1/1
1:00 2007/8/8 2
System clock configured: 02:00:00 zone-time Sat
01/01/2005
If the value of the original system clock ±
“zone-offset” is in the summer-time range,
the system clock configured is the original
system clock ± “zone-offset”
+ ”summer-offset”.
Configure: clock timezone zone-time add 1 and
clock summer-time ss one-off 1:00 2005/1/1
1:00 2005/8/8 2
System clock configured: 04:00:00 ss Sat
01/01/2005
1, 2 and 3
or 1, 3 and
2
If the value of "date-time"±"zone-offset" is
not in the summer-time range, the system
clock configured is
"date-time"±"zone-offset".
Configure: clock datetime 1:00 2007/1/1, clock
timezone zone-time add 1 and clock summer-time
ss one-off 1:00 2008/1/1 1:00 2008/8/8 2
System clock configured: 02:00:00 zone-time
Mon 01/01/2007