R3204P16-HP Load Balancing Module System Management Configuration Guide-6PW101

63
Item Descri
p
tion Remarks
If the value of "date-time"±"zone-offset" is
in the summer-time range, the system
clock configured is
"date-time"±"zone-offset"+”summer-offse
t”.
Configure: clock datetime 1:00 2007/1/1, clock
timezone zone-time add 1 and clock summer-time
ss one-off 1:00 2007/1/1 1:00 2007/8/8 2
System clock configured: 04:00:00 ss Mon
01/01/2007
[1], 2, 3 and
1 or [1], 3, 2
and 1
If “date-time” is not in the daylight saving
time range, the system clock configured is
date-time”.
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00
2008/8/8 2 and clock datetime 1:00 2007/1/1
System clock configured: 01:00:00 zone-time
Mon 01/01/2007
date-time” is in the daylight saving time
range:
If the value of “date-time-summer-offset
is not in the summer-time range, the
system clock configured is
date-time-summer-offset”;
If the value of “date-time-summer-offset
is in the summer-time range, the system
clock configured is “date-time”.
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00
2008/8/8 2 and clock datetime 1:30 2008/1/1
System clock configured: 23:30:00 zone-time
Mon 12/31/2007
Configure: clock timezone zone-time add 1, clock
summer-time ss one-off 1:00 2008/1/1 1:00
2008/8/8 2 and clock datetime 3:00 2008/1/1
System clock configured: 03:00:00 ss Tue
01/01/2008
Configuration guidelines
A device can act as a server to synchronize the clock of other devices only after its clock has been
synchronized. If the clock of a server has a stratum level higher than or equal to that of a client’s
clock, the client will not synchronize its clock to the server’s.
The synchronization process takes a period of time. Therefore, the clock status may be
unsynchronized after your configuration. In this case, you can refresh the page to view the clock
status later on.