R3721-F3210-F3171-HP High-End Firewalls Getting Started Command Reference-6PW101

54
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display flowengine-usage to display the flow engine usage statistics.
The system regularly (typically at 5-second intervals) collects the flow engine usage statistics and saves
the statistical results in the history record area. A record contains the average usage of the flow engine
in the specified interval.
The following matrix shows the command and firewall compatibility:
Command F1000-A-EI/S-EI
F1000-E
F5000 Firewall module
display flowengine-usage No Yes Yes Yes
Examples
# Display the flow engine usage statistics.
<Sysname> display flowengine-usage
Flow Engine usage:
1% in last 5 seconds
display flowengine-usage history
Syntax
display flowengine-usage history [ | { begin | exclude | include } regular-expression ]
View
Any view
Default level
1: Monitor level
Parameters
|: Filters command output by specifying a regular expression. For more information about regular
expressions, see Getting Started Guide.
begin: Displays the first line that matches the specified regular expression and all lines that follow.
exclude: Displays all lines that do not match the specified regular expression.
include: Displays all lines that match the specified regular expression.
regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use display flowengine-usage history to display the historical flow engine usage statistics.
The system regularly collects the flow engine usage statistics and saves the statistics in the history record
area. The display flowengine-usage history command displays the flow engine usage statistics for the
last 60 minutes in axes, where.
The vertical axis represents the flow engine usage. If a statistic is not a multiple of the usage step,
it is rounded up or down to the closest multiple of the usage step, whichever is closer. For example,
if the CPU usage step is 5%, the statistic 53% is rounded up to 55%, and the statistic 52% is
rounded down to 50%.
The horizontal axis represents the time.