R3721-F3210-F3171-HP High-End Firewalls Getting Started Command Reference-6PW101

77
View
System view
Default level
3: Manage level
Parameters
maintain: Specifies that when the system detects any software abnormality, it maintains the current
situation, and does not take any measure to recover itself.
reboot: Specifies that when the system detects any software abnormality, it recovers itself through
automatic reboot.
Description
Use system-failure to configure the exception handling method.
By default, the system adopts the reboot method to handle exceptions.
Examples
# Set the exception handling method to reboot.
<Sysname> system-view
[Sysname] system-failure reboot
temperature-limit
Syntax
temperature-limit slot-number lower-value upper-value
undo temperature-limit slot-number
View
System view
Default level
2: System level
Parameters
slot-number: This argument is invalid.
lower-value: Lower temperature threshold in Celsius degrees. The value ranges from 0°C to 70°C (32°F
to 158°F).
upper-value: Upper temperature threshold in Celsius degrees. The value ranges from 20°C to 90°C
(68°F to 194°F).
The upper-value argument must be larger than the lower-value argument.
Description
Use temperature-limit to set the temperature alarm threshold on a card.
Use undo temperature-limit to restore the temperature alarm threshold to the default.
By default, the lower temperature alarm threshold is 0°C (32°F), and the upper one is 50°C (122°F).
The upper temperature threshold must be larger than the lower temperature threshold.