7. Configure the data bits.
databits { 5 | 6 | 7 | 8 }
Optional.
By default, the data bits of the
console port is 8.
Data bits is the number of bits
representing one character. The
setting depends on the contexts to
be transmitted. For example, you
can set it to 7 if standard ASCII
characters are to be sent, and set it
to 8 if extended ASCII characters
are to be sent.
8. Define a shortcut key for
enabling a terminal session.
activation-key character
Optional.
By default, you can press Enter to
enable a terminal session.
9. Define a shortcut key for
terminating tasks.
escape-key { default | character }
Optional.
By default, you can press Ctrl+C to
terminate a task.
10. Configure the type of terminal
display.
terminal type { ansi | vt100 }
Optional.
By default, the terminal display
type is ANSI.
The device supports two types of
terminal display: ANSI and
VT100. HP recommends you to set
the display type of both the device
and the client to VT100. If the
device and the client use different
display types (for example, hyper
terminal or Telnet terminal) or both
are set to ANSI, when the total
number of characters of the
currently edited command line
exceeds 80, an anomaly such as
cursor corruption or abnormal
display of the terminal display may
occur on the client.
11. Configure the user privilege
level for login users.
user privilege level level
Optional.
By default, the default command
level is 3 for the console user
interface.
12. Set the maximum number of
lines on the next screen.
screen-length screen-length
Optional.
By default, the next screen displays
24 lines.
A value of 0 disables the function.
13. Set the size of history command
buffer.
history-command max-size value
Optional.
By default, the buffer saves 10
history commands at most.