R3721-F3210-F3171-HP High-End Firewalls Getting Started Guide-6PW101
72
Command Effective s
y
stem time
Confi
g
uration exam
p
le
S
y
stem time
2, 3, 1 or 3, 2, 1
date-time outside the
daylight saving time
range:
date-time
clock timezone
zone-time add 1
clock summer-time ss
one-off 1:00
2008/1/1 1:00
2008/8/8 2
clock datetime 1:00
2007/1/1
01:00:00 zone-time Mon
01/01/2007
date-time in the daylight
saving time range, but
date-time – summer-offset
outside the summer-time
range:
date-time – summer-offset
clock timezone
zone-time add 1
clock summer-time ss
one-off 1:00
2008/1/1 1:00
2008/8/8 2
clock datetime 1:30
2008/1/1
23:30:00 zone-time Mon
12/31/2007
Both date-time and
date-time – summer-offset
in the daylight saving time
range:
date-time
clock timezone
zone-time add 1
clock summer-time ss
one-off 1:00
2008/1/1 1:00
2008/8/8 2
clock datetime 3:00
2008/1/1
03:00:00 ss Tue
01/01/2008
Configuration procedure
To change the system time:
Ste
p
Command
Remarks
1. Set the system time and date.
clock datetime time date
Optional.
Available in user view.
2. Enter system view.
system-view N/A
3. Set the time zone.
clock timezone zone-name { add |
minus } zone-offset
Optional.
Universal time coordinated (UTC)
time zone by default.
4. Set a daylight saving time
scheme.
• Set a non-recurring scheme:
clock summer-time zone-name
one-off start-time start-date
end-time end-date add-time
• Set a recurring scheme:
clock summer-time zone-name
repeating start-time start-date
end-time end-date add-time
Optional.
Use either command.
By default, daylight saving time is
disabled, and the UTC time zone
applies.
Setting the idle timeout timer
Setting the idle timeout timer in the Web interface
You can set the idle timeout period for a logged-in user. The system will log an idle user off the Web
interface for security purpose after the configured period.