R3721-F3210-F3171-HP High-End Firewalls High Availability Command Reference-6PW101

70
Parameters
packet-interval: Interval for sending packets per probe operation, which ranges from 10 to 60000
milliseconds.
Description
Use probe packet-interval to configure the interval for sending packets per probe operation.
Use the undo probe-interval command to restore the default.
By default, the interval is 20 milliseconds.
Examples
# Configure the UDP jitter test group to send packets at an interval of 100 milliseconds during each
probe operation.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Syaname-nqa-admin-test-udp-jitter] probe packet-interval 100
probe packet-number
Syntax
probe packet-number packet-number
undo probe packet-number
View
UDP jitter test type view
Default level
2: System level
Parameters
packet-number: Number of packets to be sent per probe operation. It ranges from 10 to 1000 for each
probe operation in one UDP jitter test.
Description
Use probe packet-number to configure the number of packets to be sent per probe during one UDP jitter
test.
Use undo probe packet-number to restore the default.
By default, the number of packets to be sent per probe is 10 in one UDP jitter test.
Examples
# Configure the UDP jitter test group to send 100 packets per probe.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type udp-jitter
[Syaname-nqa-admin-test-udp-jitter] probe packet-number 100