R3721-F3210-F3171-HP High-End Firewalls System Management and Maintenance Command Reference-6PW101

106
[Sysname] info-center source vlan channel snmpagent log level emergencies state on
info-center synchronous
Syntax
info-center synchronous
undo info-center synchronous
View
System view
Default level
2: System level
Parameters
None
Description
Use info-center synchronous to enable synchronous information output.
Use undo info-center synchronous to disable the synchronous information output.
By default, synchronous information output is disabled.
If system information is output before you input information at a command line prompt, the system does
not display the command line prompt after the system information output.
If system information is output when you are inputting some interactive information (non Y/N
confirmation information), the system displays your input in a new line after the system information
output.
Examples
# Enable synchronous information output, and then issue the display interface ethe command to view
Ethernet interface information.
<Sysname> system-view
[Sysname] info-center synchronous
% Info-center synchronous output is on
[Sysname] display interface GigabitEthernet
At this time, the system receives log information. It displays the log information first, and then displays
your previous input, which is display interface GigabitEthernet in this example.
%Apr 29 08:12:44:71 2007 Sysname IFNET/4/LINK UPDOWN:
GigabitEthernet2/1: link status is UP
[Sysname] display interface GigabitEthe
Enter rnet to complete the display interface GigabitEhternet command, and then press the Enter key to
execute the command.
# Enable synchronous information output, and then save the current configuration (enter interactive
information).
<Sysname> system-view
[Sysname] info-center synchronous
% Info-center synchronous output is on
[Sysname] save