R3721-F3210-F3171-HP High-End Firewalls System Management and Maintenance Command Reference-6PW101

149
Field Description
Packets received according to length:
64 : 0 , 65-127 : 0 ,
128-255 : 0
256-511: 0 , 512-1023:
0 , 1024-1518: 0
Incoming-packet statistics by packet length for the statistical period:
64—Number of 64-byte packets. The value is stored in the MIB
node etherStatsPkts64Octets.
65-127—Number of 65- to 127-byte packets. The value is stored in
the MIB node etherStatsPkts65to127Octets.
128 -255 —Number of 128- to 255-byte packets. to the value is
stored in the MIB node etherStatsPkts128to255Octets.
256-511—Number of 256- to 511-byte packets. The value is stored
in the MIB node etherStatsPkts256to511Octets.
512-102 3—Number of 512- to 1023-byte packets. The value is
stored in the MIB node etherStatsPkts512to1023Octets.
1024-1518—Number of 1024- to 1518-byte packets. The value is
stored in the MIB node etherStatsPkts1024to1518Octets.
These statistics are hardware dependent. If hardware does not support
them, 0 is displayed.
rmon alarm
Syntax
rmon alarm entry-number alarm-variable sampling-interval { absolute | delta } rising-threshold
threshold-value1 event-entry1 falling-threshold threshold-value2 event-entry2 [ owner text ]
undo rmon alarm entry-number
View
System view
Default level
2: System level
Parameters
entry-number: Alarm entry index, which ranges from 1 to 65535.
alarm-variable: Alarm variable, a string of 1 to 256 characters. It can be in dotted object identifier (OID)
format (in the format of entry.integer.instance or leaf node name.instance, for example,
1.3. 6 .1. 2.1. 2.1.10 .1) , o r a n o d e n a m e l i k e i f I n O c t e t s.1. Only variables that can be parsed into INTEGER
(INTEGER, Counter, Gauge, or Time Ticks) in the ASN.1 can be used for the alarm-variable argument,
such as the instance of the leaf node (like etherStatsOctets, etherStatsPkts, etherStatsBroadcastPkts, and
so on) of the etherStatsEntry entry, the instance of the leaf node (like ifInOctets, ifInUcastPkts,
ifInNUcastPkts, and so on) of the ifEntry entry.
sampling-interval: Sampling interval, which ranges from 5 to 65,535 seconds.
absolute: Sets the sampling type to absolute. In other words, the system obtains the value of the variable
when the sampling time is reached.
delta: Sets the sampling type to delta. In other words, the system obtains the variation value of the
variable during the sampling interval when the sampling time is reached.
rising-threshold threshold-value1 event-entry1: Sets the rising threshold, where threshold-value1
represents the rising threshold, in the range –2,147,483,648 to +2,147,483,647, and event-entry1