R3721-F3210-F3171-HP High-End Firewalls System Management and Maintenance Configuration Guide-6PW101
9
Debugging information control switches
The following two switches control the debugging information output:
• Protocol debugging switch—Controls protocol-specific debugging information.
• Screen output switch—Controls whether to display the debugging information on a certain screen.
As shown in Figure 7, a
ssume that the device can provide debugging for the three modules 1, 2, and 3.
The debugging information can be output on a terminal only when both the protocol debugging switch
and the screen output switch are turned on.
Output of debugging information depends on the configurations of the information center and the
debugging commands of each protocol and functional module. Debugging information is typically
output on a terminal (including console or VTY) for display. You can also send debugging information to
other destinations. For more information, see "Configuring the information center."
Figure 7 Relationship between the protocol and screen output switch
Debugging a feature
Output from debugging commands is memory intensive. To guarantee system performance, enable
debugging only for modules that are in an exceptional condition. When debugging is complete, use the
undo debugging all command to disable all the debugging functions.
To debug a feature module and output debugging information on a terminal:
Ste
p
Command
Remarks
1. Enable the terminal
monitoring of system
information.
terminal monitor
Optional.
By default, the terminal monitoring
on the console is enabled and that
on the monitoring terminal is
disabled.
Available in user view.