HP StorageWorks B-series Data Center Fabric Manager Enterprise 10.1.4 Release Notes (5697-0085, July 2009 - includes all 10.1.x versions)

DCFM Pro services do not auto-start on Linux and Solaris
After a restart, DCFM Pro services need to be manually started on both Linux and Solaris. Until Pro
services are started, the DCFM client will fail to launch.
FC Address field displays incorrect in the Port Connectivity View
The FC address is listed incorrectly when using the Port Connectivity View. The correct FC address is
available in the Properties dialog.
Duplicate entries in Call Home notification for M-model switches
With Virtual Fabrics enabled, the Call Home notification dialog displays duplicate entries for M-model
switches.
Event priority mismatch
Error-level policies can occasionally be triggered by warning-level events.
Remote Client unable to be launched using web browser on Windows systems
If the administrator password is changed from the client and then the client is re-launched from a web
browser, the client may fail to launch.
Error when opening Zoning dialog with no message
When a user with read-only permissions for Zoning Offline launches the Zoning dialog, an error
message with no text is displayed. Add the Read-Only Zoning Online permission to the user role in
order to not see the error message dialog box.
Configdownload fails for Firmware and ALL parameters
When Configdownload is attempted from one virtual switch to another virtual switch when the
Fabric IDs are not identical and the Firmware and ALL parameters are selected, the download will
fail.
Switch name update delay
When changing the name of a switch from outside of DCFM, the new name for the switch does not
appear within DCFM for up to 15 minutes depending on SAN Size selection.
Incorrect message shown in Master Log for end-to-end monitors
Messages in the Master Log are incorrectly generated when the end-to-end monitors dialog is opened
and closed without modification, or when an end-to-end pair creation fails.
Element manager fails to launch on i10k
If the admin partition (partition 0) is removed and then reattached to a managed fabric, the element
manager no longer launches from DCFM until the DCFM services are restarted.
Tunnel ports shown instead of GigE ports
In the topology view, tunnel ports are shown instead of Gigabit Ethernet ports.
8