Configuring an FCIP interswitch/interfabric link
17
Note that when you come to the step in the wizard where you select tunnels (see Figure 95 on
page 204), you must select tunnels that correspond to the VE_Ports or VEX_Ports that you
configured earlier. Tunnels 0–7 correspond to logical ports 16–23 on GbE port 0 and to logical
ports 24–31 on GbE port 1, as shown in Table 13.
TABLE 13 Tunnels and Logical Port Numbering for GbE Ports
GbE Port Number Logical FC_Port Number Virtual Tunnel ID
ge0 16 0
ge0 17 1
ge0 18 2
ge0 19 3
ge0 20 4
ge0 21 5
ge0 22 6
ge0 23 7
ge1 24 0
ge1 25 1
ge1 26 2
ge1 27 3
ge1 28 4
ge1 29 5
ge1 30 6
ge1 31 7