HP StorageWorks B-series Data Center Fabric Manager Professional 10.1.x Release Notes (5697-0804 July 2009 - includes all 10.1.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.1.0Zoning Report not showing {D, P} alias members under
Alias section.
Symptom—When user generates report with {D,P}
alias members, the report shows {D,P} section for each
{D,P} alias member instead of members for each alias
in the Alias section
Fixed in DCFM 10.1.0Zoning Report from Zoning dialog showing same zone
members multiple times.
Symptom—When user generates report from the Zone
DB tab or Active Zone Config tab, the report shows
the same zone member multiple times.
Fixed in DCFM 10.1.0
Workaround—Get exact number of member count
From Zone properties.
In Zoning report, the Number of Members count is
wrong when a zone contains different types of
nl
members including alias.
Symptom—When user generates report, the Number
of Members column shows wrong value when a zone
contains aliases and other type members.
Fixed in DCFM 10.1.0Incorrect values are displayed for GbE port traffic in
real time graph.
Symptom—When traffic of about 139 MB/s is flowing
through a GbE port, the throughput value displayed
is around 18 MB/s which is much less. The same issue
is noted for TX RX % Utilization also.
Fixed in DCFM 10.1.0The entire tunnel IDs that are free are not displayed
in the tunnel ID drop-down in the configure tunnel step
of FCIP config wizard.
Symptom—Customer not able to see all the tunnel IDs
that are free in the switch.
Fixed in DCFM 10.1.0The (-) symbol is not displayed on Fabric Node in
product list if one of the ISLs between 2 switches is
removed.
Symptom—Indication should be displayed on product
tree also when an ISL is disabled.
Fixed in DCFM 10.1.0
Workaround—To obtain the right data, delete the
fabric and perform rediscover.
DCFM does not update when Safe Zoning or Default
Zoning is enabled/disabled using CLI, WT, or EFCM
Basic.
Symptom—DCFM, Zoning Policies dialog box, does
not update when Safe Zoning or Default Zoning is
enabled/disabled using CLI, WT, or EFCM Basic.
Fixed in DCFM 10.1.0
Workaround—Manually change the order of the
columns in the product list in the Port list view and
Node list view.
On creating a Port list/Node list View, visible attributes
and order of columns in the product list are not set
appropriately.
Symptom—On creating Port list view or node list view,
the order of columns in the product list is not changed
as per requirement.
HP StorageWorks B-series Data Center Fabric Manager Professional 15