HP StorageWorks B-series Data Center Fabric Manager Professional 10.1.x Release Notes (5697-0804 July 2009 - includes all 10.1.x versions)

SolutionClosed defect summary
Fixed in DCFM 10.1.0
Workaround—Use IP address instead of host name
for registering DCFM server as trap recipient.
Traps are not received if host name of the DCFM
server is configured in the switch as trap recipient.
Symptom—User will not receive any events from the
switch.
Fixed in DCFM 10.1.0Master log is filling so quickly with log messages it is
difficult to see errors.
Fixed in DCFM 10.1.0Not getting manageability of M-EOS switches (M6140
and Mi10K).
Fixed in DCFM 10.1.0Accept Change option does not prompt when a switch
is missing from a fabric.
Symptom—Accept Change option does not prompt
the user when a switch is removed from the fabric.
When accepting a fabric change, there is no warning
informing the operator that switches will be dropped.
Fixed in DCFM 10.1.0E_Ports in node descriptor.
Symptom—Default should be to have E_Ports
displayed. Default should be on and setting should be
some place obvious.
Fixed in DCFM 10.1.0Delete, Change Seed Switch, UnMonitor, and Monitor
buttons are enabled at any level of the fabric tree;
fabric and switch.
Fixed in DCFM 10.1.0
Workaround—Make sure there are no duplicate
names between the import file and the application, or
duplicates in the file.
Names import when unique preserves first entry, not
the last entry as designed.
Symptom—Will not have the Name expected on an
entity.
Fixed in DCFM 10.1.0Fabric display not sorting properly.
Fixed in DCFM 10.1.0
Workaround steps:
1. Do not select invalid ports.
2. Use the control button, and then select the range
of ports.
3. Use the control button to select all ports that are
required at one time.
Incorrect behavior is seen during port selection in
performance port picker.
Symptoms:
When an invalid port (device WWN) is selected,
the right selection arrow button is available but the
user is not able to select the invalid port.
When the user clicks on a port, holds the shift key
down, and then clicks some other port below it,
the entire range is not selected.
When a user selects a port [B-series switches in
interopmode 2] for the performance graphs and
moves it to the select bucket, the user will not be
able to add more ports from the available bucket
to the selected bucket.
Fixed in DCFM 10.1.0
Workaround—Delete and rediscover the Fabric.
Unmonitored Fabric cannot be re-monitored after the
seed switch password is changed.
26