53-1002448-01 15 December 2011 Fabric OS Message Reference Supporting Fabric OS v7.0.
Copyright © 2002-2011 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, NetIron, SAN Health, ServerIron, and TurboIron are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, CloudPlex, MLX, VCS, VDX, and When the Mission Is Critical, the Network Is Brocade are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
Title Publication number Summary of changes Date Fabric OS System Error Message Reference Manual 53-0000515-09 Updated for v4.4.
Title Publication number Summary of changes Date Fabric OS Message Reference 53-1001157-01 Updated for Fabric OS v6.2.0: -Revised and added new messages to FSS, KSWD, CTAP, CNM, CVLM, EM, FABR, FCIP, FW, HIL, FCR, SEC, SWCH, UCST, ZONE. -Added new chapters: CHASSIS, LFM, PMGR, TAPE. -Updated Introductory chapters. November 2008 Fabric OS Message Reference 53-1001338-01 Updated for Fabric OS v6.3.
Title Publication number Summary of changes Date Fabric OS Message Reference 53-1002149-01 Updated for Fabric OS v7.0.0: -Added new chapters: C3, CAL, MCAST_SS, RTE, and VS. -Added new messages: AG, AN, ANV, BL, C2, CDR, CCFG, ECC, EM, ESS, FABR, FCOE, FCPH, FICN, FICU, FSPF, FW, HIL, IPAD, IPS, KAC, L2SYS, LACP, LOG, MS, NS, NSM, ONM, PDM, PS, RAS, RCS, SCN, SEC, SNMP, SPM, SS, SSM, SULB, SWCH, XTUN, ZEUS, and ZONE.
Contents About This Document In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxi Document conventions . . . . .
Configuring the SNMP server hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Configuring the SNMPv1 trap recipient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Configuring the SNMPv3 trap recipient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Configuring the SNMPv3 inform recipient . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Changing the severity level of swEventTrap . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AG-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 AG-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 AG-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 AG-1014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 AG-1015 . .
AN-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 AN-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 AN-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 AN-1012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 AN-1013. . . .
AUTH-1023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 AUTH-1025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 AUTH-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 AUTH-1027. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 AUTH-1028 . . . . . . . . .
BL-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 BL-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 BL-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 BL-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 BL-1013 . .
BL-1050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 BL-1051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Chapter 8 BLL System Messages BLL-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Chapter 9 BLS System Messages BLS-1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C2-1009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 C2-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 C2-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 C2-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 C2-1014 . . . .
CCFG-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 CCFG-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 CCFG-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 CCFG-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .112 CCFG-1007 . . . . . . . . . . . . .
CHS-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124 Chapter 18 CNM System Messages CNM-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 CNM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 CNM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CNM-1035 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 CNM-1036 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134 CNM-1037 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134 CNM-1038 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134 CNM-1039 . . . . . . . . . . . .
CNM-3010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 CNM-3011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 CNM-3012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 Chapter 19 CONF System Messages CONF-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CVLC-1015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 CVLC-1016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 CVLC-1017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 CVLC-1018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156 CVLC-1019 . . . . . . . . .
CVLM-3001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 CVLM-3002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 CVLM-3003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 CVLM-3004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 CVLM-3005 . . . . . . . . . . . . .
DOT1-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 DOT1-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 DOT1-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Chapter 24 ECC System Messages ECC-1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EM-1043 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 EM-1044 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 EM-1045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191 EM-1046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .191 EM-1047 . . . . . . . . . .
Chapter 27 ESWCH System Messages ESW-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 ESW-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 ESW-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 ESW-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FABR-1024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 FABR-1029. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 FABR-1030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 FABR-1031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 FABR-1032. . . . . . . . . .
FABS-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 FABS-1014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 FABS-1015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 Chapter 31 FBC System Messages FBC-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCOE-1024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 FCOE-1025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 FCOE-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 FCOE-1027. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 FCOE-1028 . . . . . . . . . . . .
FCR-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 FCR-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 FCR-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 FCR-1005. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254 FCR-1006. . . . . . . . . .
FCR-1041 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 FCR-1042. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 FCR-1043. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 FCR-1048. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265 FCR-1049. . . . . . . . . .
FCR-1085. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 FCR-1086. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 FCR-1087. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .275 FCR-1088. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 FCR-1089. . . . . . . . . .
FICN-1029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 FICN-1030 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 FICN-1031 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 FICN-1032 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 FICN-1033 . . . . . . . . .
FICN-1066 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299 FICN-1067 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299 FICN-1068 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299 FICN-1069 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300 FICN-1070 . . . . . . . . .
FICN-1103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311 FICN-1104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .311 FICN-1105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312 FICN-1106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .312 FICN-1107 . . . . . . . . .
FICU-1006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322 FICU-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323 FICU-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323 FICU-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323 FICU-1010 . . . . . . . . .
Chapter 43 FSS System Messages FSS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335 FSS-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335 FSS-1003. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335 FSS-1004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FW-1043 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .346 FW-1044 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347 FW-1045 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347 FW-1046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347 FW-1047 . . . . . . . . . .
FW-1138 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .359 FW-1139 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .359 FW-1140 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .359 FW-1160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360 FW-1161 . . . . . . . . . .
FW-1194 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 FW-1195 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 FW-1196 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 FW-1197 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .372 FW-1198 . . . . . . . . .
FW-1334 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383 FW-1335 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383 FW-1336 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .383 FW-1337 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .384 FW-1338 . . . . . . . . . .
FW-1401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .396 FW-1402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .396 FW-1403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .397 FW-1404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .397 FW-1405 . . . . . . . . . .
FW-1511 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .407 FW-1512 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408 FW-1513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408 FW-1514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408 FW-1515 . . . . . . . . . .
FW-3022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 Chapter 46 HAM System Messages HAM-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .421 HAM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .421 HAM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HIL-1208 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .433 HIL-1301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434 HIL-1302 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434 HIL-1303 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434 HIL-1304 . . . . . . . .
Chapter 49 HLO System Messages HLO-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445 HLO-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445 HLO-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445 Chapter 50 HMON System Messages HMON-1001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ICPD-1007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .460 ICPD-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .460 Chapter 56 IPAD System Messages IPAD-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .463 IPAD-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KAC-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 KAC-1009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 KAC-1010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 KAC-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .475 KAC-1012. . . . . . . . .
Chapter 65 LANCE System Messages LANCE-1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .489 Chapter 66 LFM System Messages LFM-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .491 LFM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .491 LFM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MCAST_SS-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .499 MCAST_SS-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 MCAST_SS-1014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 MCAST_SS-1015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .500 MCAST_SS-1016 . . . . . . . . . . . . . . . . . . .
MS-1025 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .513 MS-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 MS-1027 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 MS-1028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 MS-1029 . . . . . . . . .
NSM-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .525 NSM-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526 NSM-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526 NSM-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .526 NSM-1006 . . . . . . . . . . . .
PDM-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .535 PDM-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .535 PDM-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .536 PDM-1012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .536 PDM-1013 . . . . . . . . . . . .
PMGR-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .547 Chapter 83 PORT System Messages PORT-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549 PORT-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .549 PORT-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAS-1006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .560 RAS-1007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .560 RAS-2001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .560 RAS-2002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .561 RAS-2003 . . . . . . . . . .
RPCD-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 571 RPCD-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 571 RPCD-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .572 RPCD-1005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .572 RPCD-1006 . . . . . . . . . . . .
SEC-1032. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585 SEC-1033. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585 SEC-1034. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .585 SEC-1035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .586 SEC-1036. . . . . . . . . .
SEC-1079. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .595 SEC-1080. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 SEC-1081. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 SEC-1082. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .596 SEC-1083. . . . . . . . . .
SEC-1118. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .606 SEC-1119. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .607 SEC-1121. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .607 SEC-1122. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .607 SEC-1123. . . . . . . . . .
SEC-1180. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617 SEC-1181. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617 SEC-1182. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .618 SEC-1183. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .618 SEC-1184. . . . . . . . .
SEC-1310. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .628 SEC-1311. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629 SEC-1312. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629 SEC-1313. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .629 SEC-1314. . . . . . . . . .
SEC-3063 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SEC-3064 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SEC-3065 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SEC-3066 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .639 SEC-3067 . . . . . . . . . . . .
SPC-2007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651 SPC-2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .651 SPC-2009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .652 SPC-2010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .652 SPC-2011. . . . . . . . . . .
SPM-1008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .662 SPM-1009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .663 SPM-1010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .663 SPM-1011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .663 SPM-1012 . . . . . . . . . . . .
SPM-3029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .672 Chapter 99 SS System Messages SS-1000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .673 SS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .673 SS-1002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SSMD-1214 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683 SSMD-1215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683 SSMD-1216 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .684 SSMD-1217 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .684 SSMD-1300 . . . . . . . . . . . . .
SULB-1018. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 SULB-1020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 SULB-1021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .700 SULB-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .701 SULB-1023 . . . . . . . . . . . . .
SWCH-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 SWCH-1014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 SWCH-1015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 SWCH-1016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 SWCH-1017 . . . . . . . . . . .
TRCE-1008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .723 TRCE-1009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .723 TRCE-1010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .724 TRCE-1011. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .724 TRCE-1012. . . . . . . . . . . .
Chapter 111 VS System Messages VS-1001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .735 VS-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .735 VS-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .735 VS-1004 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XTUN-2007 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745 XTUN-2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745 XTUN-2009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746 XTUN-2010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746 XTUN-2011 . . . . . . . . . . .
ZONE-1022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .758 ZONE-1023 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .758 ZONE-1024 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .758 ZONE-1026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .758 ZONE-1027 . . . . . . . . . . . . .
ZONE-1060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .768 Section II Chapter 116 Audit Log Messages AUDIT AG System Messages AG-1033. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 771 AG-1034. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 771 AG-1035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 120 AUDIT CCFG System Messages CCFG-1002 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .783 CCFG-1003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .783 CCFG-1013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .783 Chapter 121 AUDIT CNM System Messages CNM-3001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CVLM-3012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .794 CVLM-3013 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .794 CVLM-3014 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .794 CVLM-3015 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .795 CVLM-3016 . . . . . . . . . . . . .
FW-1404 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .808 FW-1405 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .808 FW-1406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .808 FW-3001 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SEC-3005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .825 SEC-3006 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .825 SEC-3007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .825 SEC-3008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .826 SEC-3009 . . . . . . . . . . .
SEC-3046 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836 SEC-3047. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836 SEC-3048 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836 SEC-3049 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .836 SEC-3050 . . . . . . . . . . .
SPM-3016 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .847 SPM-3017 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .847 SPM-3018 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .848 SPM-3019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .848 SPM-3020 . . . . . . . . . . . .
SULB-1039 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .865 SULB-1040 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .865 SULB-1041. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .866 SULB-1042 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ZONE-3019 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .878 ZONE-3020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .878 ZONE-3021 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .879 ZONE-3022 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .879 ZONE-3023 . . . . . . . . . . . . .
About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix • Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxix • What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxi • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . lxxxii • Notice to the reader . . . . . . . . . . . . .
• • • • • • • • • • • • Brocade 5410 Brocade 5424 Brocade 5450 Brocade 5460 Brocade 5470 Brocade 5480 Brocade 6505 Brocade 6510 Brocade 7800 Brocade 8000 Brocade Encryption Switch Brocade DCX Backbone and Brocade DCX-4S Backbone - FC8-16 port blade FC8-32 port blade FC8-48 port blade FC8-64 port blade FC10-6 port blade FCOE10-24 DCX Blade FR4-18i router blade FS8-18 Encryption Blade FX8-24 DCX Extension Blade • Brocade DCX 8510-8 Backbone and Brocade DCX 8510-4 Backbone - FC8-32E port blade - FC8-48E po
The following blades are not supported in any chassis operating with Fabric OS v7.0.
Document conventions This section describes text formatting conventions and important notice formats used in this document.
Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. NOTE A note provides a tip, guidance, or advice, emphasizes important information, or provides a reference to related information. ATTENTION An Attention statement indicates potential damage to hardware or data.
Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Brocade resources To get up-to-the-minute information, go to http://my.brocade.com to register at no cost for a user ID and password. White papers, online demonstrations, and data sheets are available through the Brocade website at: http://www.brocade.com/products-solutions/products/index.page For additional Brocade documentation, visit the Brocade website: http://www.brocade.
• syslog message logs 2. Switch Serial Number The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below.
lxxxvi Fabric OS Message Reference 53-1002448-01
Chapter Introduction to System Messages 1 In this chapter • Overview of system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Configuring the syslog message destinations . . . . . . . . . . . . . . . . . . . . . . . . . 4 • Configuring the SNMP server hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 • Changing the severity level of swEventTrap. . . . . . . . . . . . . . . . . . . . . . . . . .
1 Overview of system messages For information on displaying and clearing the RASLog messages, refer to “Displaying and clearing system message logs” on page 15. Audit log messages Event auditing is designed to support post-event audits and problem determination based on high-frequency events of certain types such as security violations, zoning configuration changes, firmware downloads, and certain types of fabric events. Audit messages flagged as AUDIT are not saved in the switch error logs.
Overview of system messages 1 Event auditing is a configurable feature, set to off by default. You must enable event auditing using the auditCfg --enable command to send the events to a configured remote host. Syslogd must be configured for logging audit messages. You can set up filters to screen out particular classes of events using the auditCfg command.
1 Configuring the syslog message destinations System error message logging The RASLog service generates and stores messages related to abnormal or erroneous system behavior. It includes the following features: • All RASLog error messages are saved to nonvolatile storage by default. • The system error message log can save a maximum of 1024 messages in random access memory (RAM). • The system message log is implemented as a circular buffer.
Configuring the syslog message destinations 1 For the Brocade DCX family of switches, any security violations that occur through Telnet, HTTP, or serial connections are not propagated between CPs. Security violations on the active CP are not propagated to the standby CP counters in the event of a failover, nor do security violations on the standby CP get propagated to the active CP counters.
1 Configuring the syslog message destinations 3. Execute the errFilterSet command to verify the configured filter settings. switch:admin> errfilterset console: filter severity = ERROR SNMP management station When an unusual event, error, or a status change occurs on the device, an event notification is sent to the SNMP management station. Fabric OS v7.0.1 supports two types of event notifications: traps (in SNMPv1 and SNMPv3) and informs (in SNMPv3).
Configuring the SNMP server hosts 1 SNMP informs An SNMP inform is similar to the SNMP trap except that the management station that receives an SNMP inform acknowledges the system message with an SNMP response packet data unit (PDU). If the sender does not receive the SNMP response PDU, the inform request can be sent again. An SNMP inform request is saved in the switch memory until a response is received or the request times out.
1 Configuring the SNMP server hosts 3. Execute the snmpConfig --show snmpv1 command to verify the SNMPv1 agent configuration. switch:admin> snmpconfig --show snmpv1 SNMPv1 community and trap recipient configuration: Community 1: Secret C0de (rw) Trap recipient: 10.24.32.122 Trap port: 162 Trap recipient Severity level: 5 Community 2: OrigEquipMfr (rw) Trap recipient: fec0:60:69bc:200:213:72ff:fe64:47b9 Trap port: 162 Trap recipient Severity level: 5 Community 3: private (rw) Trap recipient: WTQAXP.englab.
Configuring the SNMP server hosts 1 Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]): (2..2) [2] User (ro): [snmpuser2] Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3] Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]): (2..2) [2] User (ro): [snmpuser3] Auth Protocol [MD5(1)/SHA(2)/noAuth(3)]: (1..3) [3] Priv Protocol [DES(1)/noPriv(2)/3DES(3)/AES128(4)/AES192(5)/AES256(6)]): (2..2) [2] SNMPv3 trap recipient configuration: Trap Recipient's IP address : [172.
1 Configuring the SNMP server hosts Configuring the SNMPv3 inform recipient To configure the SNMPv3 host to receive the SNMP informs, perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set snmpv3 command to configure the inform recipient. When prompted to enable the SNMP informs, enter true or t. Informs are disabled by default.
Changing the severity level of swEventTrap 1 Trap Recipient's IP address : [0.0.0.0] Trap Recipient's IP address : [0.0.0.0] Committing configuration.....done. NOTE To receive the SNMP informs, the username, the authentication protocol, the privacy protocol, and the engine ID must match between the switch and the management station. 3. Execute the snmpConfig --show snmpv3 command to verify the SNMP agent configuration.
1 Changing the severity level of swEventTrap To change the severity level of swEventTrap, perform the following steps. 1. Log in to the switch as admin. 2. Execute the snmpConfig --set mibCapability command to configure MIBs interactively. All the supported MIBs and associated traps are displayed. You can change the DesiredSeverity for swEventTrap to 1 (Critical), 2 (Error), 3 (Warning), or 4 (Informational). The default value is 0.
Commands for displaying and configuring the system message logs 1 bdClearTrap: YES FE-MIB (yes, y, no, n): [yes] SW-MIB (yes, y, no, n): [yes] FA-MIB (yes, y, no, n): [yes] FICON-MIB (yes, y, no, n): [yes] HA-MIB (yes, y, no, n): [yes] FCIP-MIB (yes, y, no, n): [yes] ISCSI-MIB (yes, y, no, n): [yes] IF-MIB (yes, y, no, n): [yes] BD-MIB (yes, y, no, n): [yes] SW-TRAP (yes, y, no, n): [yes] swFault (yes, y, no, n): [yes] swSensorScn (yes, y, no, n): [yes] swFCPortScn (yes, y, no, n): [yes] swEventTrap (yes,
1 Commands for displaying and configuring the system message logs TABLE 3 14 Commands for viewing or configuring the system parameters and message logs Command Description auditCfg Configures the audit message log. auditDump Displays or clears the audit log. errClear Clears all error log messages for all switch instances on this control processor (CP). errDelimiterSet Sets the error log start and end delimiter for messages pushed to the console.
Displaying and clearing system message logs TABLE 3 1 Commands for viewing or configuring the system parameters and message logs (Continued) Command Description syslogdFacility Changes the syslogd facility. syslogdIpAdd Adds an IP address as a recipient of system messages. syslogdIpRemove Removes an IP address as a recipient of system messages. syslogdIpShow Views the currently configured IP addresses that are recipients of system messages.
1 Displaying, clearing, and configuring Audit messages Displaying RASLog messages one message at a time To display the system message log one message at a time, perform the following steps. 1. Log in to the switch as admin. 2. Enter the errShow command at the command line. switch:admin> errshow Version: 7.0.
Displaying, clearing, and configuring Audit messages 1 0 AUDIT, 2011/01/14-06:06:49 (UTC), [RAS-2001], INFO, SYSTEM, admin/admin/10.70.4.102/telnet/CLI, ad_0/switch/FID 128, , Audit message log is enabled. 2 AUDIT, 2011/01/14-06:07:03 (UTC), [SEC-3020], INFO, SECURITY, admin/admin/10.70.4.102/telnet/CLI ad_0/switch, , Event: login, Status: success, Info: Successful login attempt via SERIAL. 3 AUDIT, 2011/01/14-06:07:33 (UTC), [SULB-1003], INFO, FIRMWARE, admin/admin/10.70.4.
1 Reading the system messages You must configure the syslog daemon to send the Audit events to a configured remote host using the syslogdIpAdd command. For more information on configuring the syslog server, refer to “Configuring a syslog server” on page 5. Reading the system messages This section provides information about reading the RASLog and Audit messages. Reading a RAS system message This section provides information about reading system messages.
Reading the system messages TABLE 4 1 System message field description (Continued) Variable name Description Flags For most messages, this field contains a space character (null value) indicating that the message is neither an AUDIT or FFDC message. Messages may contain the following values: • FFDC – Indicates that additional first failure data capture information has also been generated for this event. • FID – The Fabric ID that can range from 0 to 128.
1 Reading the system messages TABLE 5 Audit message field description (Continued) Variable name Description Time Stamp The system time (UTC) when the message was generated on the switch. The RASLog subsystem will support an internationalized time stamp format based on the “LOCAL” setting. Event ID The message module and number. These values uniquely identify each message in the Fabric OS and reference the cause and actions recommended in this manual.
Responding to a system message 1 Responding to a system message This section provides procedures on gathering information on system messages. Looking up a system message Error messages in this manual are arranged alphabetically. To look up an error message, copy down the module (see Table 6 on page 23) and the error code and compare this with the Table of Contents to determine the location of the information for that error message.
1 Responding to a system message Common steps to be followed when troubleshooting a system message are as follows. • Execute the errDump command on each logical switch. • Execute the supportFtp command (as needed) to set up automatic FTP transfers, and then execute the supportSave command. Support Fabric OS creates a number of files that can help support personnel troubleshoot and diagnose a problem. This section describes those files and how to access or save the information for support personnel.
System module descriptions 1 System module descriptions Table 6 provides a summary of the system modules for which messages are documented in this guide; the system modules are listed alphabetically by name. TABLE 6 System module descriptions System module Description AG Access Gateway (AG) allows multiple hosts (or HBAs) to access the fabric using fewer physical ports.
1 System module descriptions TABLE 6 24 System module descriptions (Continued) System module Description DAUTH DAUTH error messages indicate problems with the 802.1x authentication module of the Fabric OS. ECC Error Checking and Correction (ECC) error messages indicate single-bit and multiple-bit errors in the Dynamic Random Access Memory (DRAM) devices. ECC is a technology that helps to correct memory errors.
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description FSS The Fabric OS state synchronization framework provides facilities by which the active control processor (CP) can synchronize with the standby CP, enabling the standby CP to take control of the switch nondisruptively during failures and software upgrades.
1 System module descriptions TABLE 6 26 System module descriptions (Continued) System module Description KSWD (continued) • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Authentication daemon (authd) Blade Manager daemon (bmd) Common Access Layer daemon (cald) Cluster Node Manager daemon (cnmd) DAUTH daemon (dauthd) Diagnostics daemon (diagd) Environment Monitor daemon (emd) Event Manager daemon (evmd) Exchange Switch Support daemon (essd) FA-API rp
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description KSWD (continued) • • • • KTRC Kernel RAS trace module. L2SYS L2SYS error messages indicate problems with the Layer 2 System manager that controls the Layer 2 forwarding engine and controls the learning/aging/forwarding functionality. LACP LACP error messages indicate problems with the Link Aggregation Control Protocol module of the Fabric OS.
1 System module descriptions TABLE 6 28 System module descriptions (Continued) System module Description ONMD ONMD error messages indicate problems with the Operation, Administration and Maintenance module of the Fabric OS. PDM Parity data manager (PDM) is a user-space daemon responsible for the replication of persistent configuration files from the primary partition to the secondary partition and from the active CP blade to the standby CP blade.
System module descriptions TABLE 6 1 System module descriptions (Continued) System module Description SNMP Simple Network Management Protocol (SNMP) is a universally supported low-level protocol that allows simple get, get next, and set requests to go to the switch (acting as an SNMP agent). It also allows the switch to send traps to the defined and configured management station. Brocade switches support six management entities that can be configured to receive these traps.
1 System module descriptions TABLE 6 30 System module descriptions (Continued) System module Description XTUN XTUN messages are generated by the 7800/FX8-24 FCIP Tunnel implementation. These messages indicate status of FCIP tunnels, FCIP emulation events for FCP traffic, or FCIP debug information (FTRACE buffer status changes). ZEUS Zeus error messages indicate problems with the Zeus driver module.
Section RASLog Messages I This section provides the RASLog messages, including: • AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 • AN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 • ANV System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 • AUTH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• FCPD System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FCPH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FCR System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FICON System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • FICU System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• MSTP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NBFS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • NSM System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • ONMD System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• XTUN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 741 • ZEUS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749 • ZONE System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter AG System Messages 2 AG-1001 Message , [AG-1001], ,, ERROR, , N_Port ID virtualization (NPIV) is not supported by fabric port connected to port . Probable Cause Indicates that the N_Port ID virtualization (NPIV) capability is not supported by the fabric port to which the Access Gateway is connected. Recommended Action • On switches running Fabric OS 6.0.
2 AG-1004 Recommended Action Severity Configure two or more N_Ports to connect to the same fabric; then execute the ag --failoverenable command to enable failover on these N_Ports. WARNING AG-1004 Message , [AG-1004], ,, ERROR, , Invalid response to fabric login (FLOGI) request from the fabric for N_Port . Probable Cause Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the specified N_Port.
AG-1007 2 AG-1007 Message , [AG-1007], ,, WARNING, , FLOGI response not received for the N_Port connected to the fabric. Probable Cause Indicates the N_Port connected to the fabric switch is not online. The specified N_Port has been disabled. Recommended Action Check the connectivity between the Access Gateway N_Port and the fabric switch port.
2 AG-1011 Recommended Action Severity Check the configuration of the fabric switch connected to the Access Gateway. If the message persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. WARNING AG-1011 Message , [AG-1011], ,, WARNING, , Sending FDISC failed on N_Port .
AG-1014 2 AG-1014 Message , [AG-1014], ,, INFO, , Failing back F_Ports mapped to N_Port . Probable Cause Indicates the specified N_Port is failing back F_Ports mapped to the specified N_Port. Recommended Action Execute the ag --mapShow command to display updated F_Port- to-N_Port mapping. Severity INFO AG-1015 Message , [AG-1015], ,, WARNING, , Unable to find online N_Ports to connect to the fabric.
2 AG-1018 Recommended Action Severity Execute the switchShow command to display the status of all ports in the system. Execute the portCfgShow command to display the list of ports currently configured as N_Ports. WARNING AG-1018 Message , [AG-1018], ,, ERROR, , Host port should not be connected to port , which is configured as N_Port. Probable Cause Indicates that an Initiator or Target is erroneously connected to a port configured for N_Port operation.
AG-1021 2 AG-1021 Message , [AG-1021], ,, WARNING, , Unable to do Preferred-Failover of F_Port . Failover across different fabric is not supported. Probable Cause Indicates that failover across N_Ports connected to different fabrics is not supported. Recommended Action Change the preferred N_Port settings for this F_Port using the ag --prefset command.
2 AG-1025 Recommended Action Severity Execute the ag --mapShow command to display the updated F_Port-to-N_Port mapping. INFO AG-1025 Message , [AG-1025], ,, ERROR, , Port group of Slave N_Port is different than its Master N_Port . Probable Cause Indicates that the port groups of the Master and Slave N_Ports are different while the Trunk Area assigned to the attached F_Ports on the edge switch is the same.
AG-1028 2 AG-1028 Message , [AG-1028], ,, WARNING, , Device with Port WWN tried to perform fabric login through port , without having access permission. Probable Cause Indicates the device does not have login access for that port, as per Advanced Device Security (ADS) policy set by the user. Recommended Action Add the device to the ADS allow list for the specified port using the ag --adsadd command.
2 AG-1032 Recommended Action Severity Check the device configuration. WARNING AG-1032 Message , [AG-1032], ,, INFO, , N_Port (ID: ) has recovered from an unreliable state. Probable Cause Indicates that the port state has been stable for the last five minutes. Recommended Action No action is required.
AG-1036 Recommended Action Severity 2 No action is required. INFO AG-1036 Message , [AG-1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration. Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended Action No action is required.
2 AG-1039 AG-1039 Message , [AG-1039], ,, INFO, , F_Port was reset because a WWN mapped device using it, through N_Port , went offline. Probable Cause Indicates that a port needed to be reset because an N_Port went offline and the changes need to be propagated to all involved devices. Recommended Action No action is required. This port reset was not an error.
Chapter AN System Messages 3 AN-1001 Message , [AN-1001], ,, ERROR, , Failed to allocate memory: Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR AN-1002 Message , [AN-1002], ,, ERROR, , Failed to initialize; rc = .
3 AN-1004 AN-1004 Message , [AN-1004], ,, WARNING, , Congestion bottleneck on port /. pct. of secs. affected. Probable Cause Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
AN-1012 Recommended Action Severity 3 Contact your vendor's customer support for assistance. WARNING AN-1012 Message , [AN-1012], ,, WARNING, , Credits did not return from other end. Complete loss of credits on a VC on slot port . Probable Cause Indicates a credit loss. Recommended Action If this message is not followed by an AN-1013 message, please contact your vendor's customer support for assistance.
3 50 AN-1013 Fabric OS Message Reference 53-1002448-01
Chapter ANV System Messages 4 ANV-1001 Message , [ANV-1001], ,, ERROR, , Port port fault. Change the SFP or check the cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Action Verify that compatible SFPs are used on the peer ports, the SFPs have not deteriorated, and the fibre channel cable is not faulty.
4 ANV-1004 ANV-1004 Message , [ANV-1004], ,, ERROR, , S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x. Probable Cause Indicates an internal error in the ASIC hardware that may degrade the data traffic. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the faulted blade.
ANV-1008 4 ANV-1008 Message , [ANV-1008], ,, ERROR, , S, C: MAC-VID classifier table is full. No space for new entry. Probable Cause Indicates that the Media Access Control (MAC) VLAN ID (VID) classifier table is full and no more entries can be added. Recommended Action Delete some of the existing unused rules using the portcfg arp command and then add new entries.
4 54 ANV-1016 Fabric OS Message Reference 53-1002448-01
Chapter AUTH System Messages 5 AUTH-1001 Message , [AUTH-1001], ,, INFO, , has been successfully completed. Probable Cause Indicates that the secret database operation has been updated using the secAuthSecret command. The values for Operation type can be “set” or “remove”. Recommended Action No action is required.
5 AUTH-1004 AUTH-1004 Message , [AUTH-1004], ,, ERROR, , Failed to set type to . Probable Cause Indicates that the authUtil command has failed to set the authentication configuration value. The data type is either authentication type, DH group type, or policy type. Recommended Action Retry the authUtil command.
AUTH-1008 Recommended Action Severity 5 Run the authUtil command to make sure the local switch supports the specified protocols: Fibre channel authentication protocol (FCAP) or Diffie Hellman - challenge handshake authentication protocol (DH-CHAP). ERROR AUTH-1008 Message , [AUTH-1008], ,, ERROR, , No security license, operation failed. Probable Cause Indicates that the switch does not have a security license.
5 AUTH-1012 AUTH-1012 Message , [AUTH-1012], ,, WARNING, , Authentication is rejected: port explain reason . Probable Cause Indicates that an authentication is rejected because the remote entity does not support authentication. Recommended Action Make sure the entity at the other end of the link supports authentication.
AUTH-1016 5 AUTH-1016 Message , [AUTH-1016], ,, ERROR, , Invalid value to start HBA authentication port: , . Probable Cause This may relate to an internal failure. Recommended Action Copy the message, collect switch information using the supportShow command, and contact your switch service provider.
5 AUTH-1022 Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
AUTH-1025 5 If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1025 Message , [AUTH-1025], ,, ERROR, , Failed to get during : port . Probable Cause Indicates that the authentication process failed to get the expected information during the specified authentication phase.
5 AUTH-1028 Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-1028 Message Probable Cause , [AUTH-1028], ,, ERROR, , Failed to allocate for : port .
AUTH-1030 5 AUTH-1030 Message , [AUTH-1030], ,, ERROR, , Invalid message code for message: port . Probable Cause Indicates the receiving payload does not have valid message code for a particular authentication phase. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
5 AUTH-1033 AUTH-1033 Message , [AUTH-1033], ,, ERROR, , Disable port due to unauthorized switch . Probable Cause Indicates that an entity was not configured in the switch connection control (SCC) policy and tried to connect to the port.
AUTH-1036 5 AUTH-1036 Message , [AUTH-1036], ,, ERROR, , Invalid state for : port . Probable Cause Indicates that the switch received an unexpected authentication message. Recommended Action Usually this problem is transient. The authentication might fail. Reinitialize authentication using the portDisable and portEnable commands or the switchDisable and switchEnable commands.
5 AUTH-1039 AUTH-1039 Message , [AUTH-1039], ,, ERROR, , Neighboring switch has conflicting authentication policy: Port disabled. Probable Cause Indicates that the neighboring switch has a conflicting authentication policy enabled. The_E-Port has been disabled, because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy.
AUTH-1042 5 AUTH-1042 Message , [AUTH-1042], ,, ERROR, , Port has been disabled, because authentication failed with code '' and explanation ''. Probable Cause The specified port has been disabled, because the connecting switch/device failed to authenticate. The error might indicate that an invalid entity attempted to connect to the switch.
5 AUTH-1045 AUTH-1045 Message , [AUTH-1045], ,, ERROR, , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch. Recommended Action Check the certificate availability using the pkiShow command.
Chapter BKSW System Messages 6 BKSW-1003 Message Probable Cause , [BKSW-1003], , FFDC, WARNING, , kSWD: . Indicates a warning state within the system. A critical application error was reported in the watchdog subsystem. This message is used to convey information regarding the state of the system. Refer to the Warning message variable for specific information. The switch will reboot (on single-CP switches) or fail over (on dual-CP switches).
6 70 BKSW-1003 Fabric OS Message Reference 53-1002448-01
Chapter BL System Messages 7 BL-1000 Message , [BL-1000], ,, INFO, , Initializing ports... Probable Cause Indicates that the switch has started initializing the ports. Recommended Action No action is required. Severity INFO BL-1001 Message , [BL-1001], ,, INFO, , Port initialization completed. Probable Cause Indicates that the switch has completed initializing the ports.
7 BL-1003 BL-1003 Message , [BL-1003], , FFDC, CRITICAL, , Faulting blade in slot . Probable Cause Indicates a faulty blade in the specified slot number. Recommended Action Make sure that the blade is seated correctly. If the blade is seated correctly, restart or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. Refer to the Fabric OS Command Reference for more information on these commands.
BL-1007 7 BL-1007 Message , [BL-1007], ,, WARNING, , blade #: blade state is inconsistent with EM. bl_cflags 0x, slot_on , slot_off , faulty , status . Probable Cause Indicates that a failover occurred while a blade was initializing on the previously active control processor (CP). Recommended Action No action is required. The blade is reinitialized.
7 BL-1010 BL-1010 Message , [BL-1010], ,, WARNING, , Blade in slot inconsistent with the hardware settings. Probable Cause Indicates that a failover occurred while some hardware changes were being made on the previously active control processor (CP) (such as changing the domain ID). Recommended Action No action is required. This blade has been reinitialized.
BL-1013 7 If the message persists, replace the blade or the (nonbladed) switch. Severity ERROR BL-1013 Message , [BL-1013], ,, ERROR, , bport port is faulted. status=0x Port will be re-enabled in 1 minute. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch operation.
7 BL-1015 BL-1015 Message , [BL-1015], ,, ERROR, , bport port is faulted. status=0x. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this number might not correspond to a user port number.
BL-1018 Recommended Action Severity 7 No action is required. INFO BL-1018 Message , [BL-1018], ,, INFO, , Slot Initialization completed. Probable Cause Indicates that the slot has completed initializing the ports. Recommended Action No action is required.
7 BL-1021 BL-1021 Message , [BL-1021], ,, INFO, , Retry , internal port retry initialization, . Probable Cause Indicates that the switch had internal ports not online and that the system is retrying to bring the ports that failed back online. Recommended Action No action is required.
BL-1024 7 BL-1024 Message , [BL-1024], ,, INFO, , All ports on the blade in slot will be reset as part of the firmware upgrade. Probable Cause Indicates that a recent firmware upgrade caused the blade's firmware to be upgraded and resulted in the cold upgrade. As part of the upgrade, all datapath elements were reset. Recommended Action No action is required.
7 BL-1028 Recommended Action Severity Restart or power cycle the blade. If the message persists, replace the blade. CRITICAL BL-1028 Message , [BL-1028], ,, CRITICAL, , Switch faulted; internal processor was reset before switch init completed. Probable Cause Indicates that the switch's internal processor was reset before the initialization completed. Recommended Action Restart or power cycle the switch. Severity If the message persists, replace the switch.
BL-1031 7 BL-1031 Message , [BL-1031], ,, CRITICAL, , Link timeout in internal port (slot , port ) resulted in blade fault. Use slotpoweroff/slotpoweron to recover the blade. Probable Cause Indicates that link timeout occurred in one of the backend internal ports. Recommended Action Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
7 BL-1035 Recommended Action Severity No action is required. INFO BL-1035 Message , [BL-1035], ,, INFO, , Slot iSCSI port Initialization completed. Probable Cause Indicates that the slot has completed initializing the specified iSCSI port. Recommended Action No action is required.
BL-1039 Recommended Action Severity 7 Restart the switch. If the message persists, replace the switch. CRITICAL BL-1039 Message , [BL-1039], ,, CRITICAL, , Inconsistent FPGA image version detected, faulting the blade in slot . Probable Cause Indicates that the FPGA image version is incompatible with the software version. Recommended Action Power cycle the blade. If the message persists, replace the blade.
7 BL-1046 BL-1046 Message , [BL-1046], ,, ERROR, , error on SFP in Slot /Port (). Try reseating or replacing it. Probable Cause Indicates the checksum in an area on the SFP does not match with the computed one or there is problem accessing the data.
BL-1050 Recommended Action Severity 7 No action is required. INFO BL-1050 Message , [BL-1050], ,, WARNING, , Incompatible Blade Processor FPGA version with FOS7.0 firmware in slot= on FX8-24. Contact support for upgrade instructions. Probable Cause Indicates that the blade processor FPGA version with Fabric OS v7.0.0 firmware in the specified slot is incompatible on FX8-24 blade.
7 86 BL-1051 Fabric OS Message Reference 53-1002448-01
Chapter BLL System Messages 8 BLL-1000 Message Probable Cause , [BLL-1000], , FFDC, CRITICAL, , ASIC driver detected Slot port as faulty (reason: ). Indicates that a blade regulation problem was reported on the specified slot. The blade is faulted.
8 BLL-1000 Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems.
Chapter BLS System Messages 9 BLS-1000 Message , [BLS-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid=. Probable Cause Indicates that the hardware is not responding to a command request, possibly because it is busy. Recommended Action Retry the command.
9 BLS-1003 BLS-1003 Message , [BLS-1003], , INFO, , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec or IKE policy was deleted and the configuration file was updated. Recommended Action No action is required. Severity INFO BLS-1004 Message , [BLS-1004], ,, INFO, , Tape Read Pipelining is being disabled slot () port () tunnel ().
Chapter BM System Messages 10 BM-1001 Message Probable Cause , [BM-1001], ,, ERROR, , BM protocol version in slot . Indicates that the firmware running on the control processor (CP) cannot communicate with the application processor (AP) blade in the indicated slot and determine the AP blade's firmware version. • • Recommended Action Severity The CP blade is running a later version of firmware than the AP blade.
10 BM-1004 Recommended Action Severity Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. WARNING BM-1004 Message Probable Cause Recommended Action Severity , [BM-1004], ,, INFO, , Blade firmware on slot is not consistent with system firmware . Auto-leveling blade firmware to match system firmware.
BM-1007 10 BM-1007 Message , [BM-1007], ,, INFO, , If set, clear EX/VEX/FC Fastwrite configuration for all ports for blade in slot . Probable Cause Indicates the specified blade was detected for the first time after an FR4-18i was previously configured in the same slot. The new blade requires the specified port configurations to be cleared. Recommended Action No action is required. The blade ports are cleared automatically.
10 BM-1053 Recommended Action Severity No action is required. The blade ports are cleared automatically. INFO BM-1053 Message , [BM-1053], , FFDC, WARNING, , Failed to establish connection between CP and Application Processor. Faulting switch. Probable Cause Indicates the control processor (CP) could not establish a connection with the application processor to communicate.
BM-1056 10 BM-1056 Message Probable Cause , [BM-1056], ,, INFO, , AP is not configured. Persistently disabling all ports on the switch. Indicates the policy of the specified switch is to persistently disable all ports the first time the AP is detected. This may be caused by one of the following: • The AP was detected for the first time on this switch. • The switch was configured under a different mode.
10 96 BM-1058 Fabric OS Message Reference 53-1002448-01
Chapter C2 System Messages 11 C2-1001 Message , [C2-1001], ,, ERROR, , Port port faulted due to SFP validation failure. Please check if the SFP is valid for the configuration. Probable Cause Indicates a deteriorated SFP, an incompatible SFP pair, or a faulty cable between the peer ports. Recommended Action Verify that you are using compatible SFPs on the peer ports.
11 C2-1006 C2-1006 Message Probable Cause Message , [C2-1006], ,, WARNING, , S,C: Internal link errors reported, no hardware faults identified, continuing monitoring: fault1:, fault2: thresh1:0x. Indicates a warning that some internal link errors have been detected. These can be normal in an active running system.
C2-1009 11 C2-1009 Message Message , [C2-1009], ,, WARNING, , S,P(): portcfglongdistance vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the link. Probable Cause Indicates portcfglongdistance vc_translation_link_init 1 overwrites fill word IDLE. ARB will be used on the link. Recommended Action No action is required.
11 C2-1013 C2-1013 Message Message , [C2-1013], ,, WARNING, , S,P(): Duplicate rte_tbl_select detected! Probable Cause Indicates that the selected table is corrupted. Recommended Action This message must have a matching message for the other duplicate. Reset both the specified ports. If it is a trunk, reset the entire trunk.
C2-1017 Recommended Action Severity 11 Whenever this error is observed persistently, power cycle the specified blade. If the problem persists, replace the blade. ERROR C2-1017 Message Message , [C2-1017], ,, ERROR, , Blade in Slot failed due to unavailability of ports in the internal trunk. Probable Cause Indicates that the blade failed due to unavailability of the ports in the internal trunk.
11 102 C2-1019 Fabric OS Message Reference 53-1002448-01
Chapter C3 System Messages 12 C3-1001 Message , [C3-1001], ,, ERROR, , Port failed due to SFP validation failure. Check if the SFP is valid for the configuration. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between the peer ports.
12 C3-1006 C3-1006 Message , [C3-1006], ,, WARNING, , S,C: Various non critical hardware errors were observed: fault1:0x, fault2:0x thresh1:0x. Probable Cause Indicates some errors found in hardware that may or may not impact data traffic. Recommended Action No action is required.
C3-1010 Recommended Action Severity 12 No action is required. WARNING C3-1010 Message , [C3-1010], ,, CRITICAL, , S,C: Above normal hardware errors were observed: fault1:, fault2: thresh2:0x. Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic. Recommended Action Whenever this error is observed persistently, power cycle the specified blade.
12 C3-1013 C3-1013 Message , [C3-1013], ,, INFO, , Maximum wait cycles to recover the lost frame or credit is exceeded on the internal Port Slot ,P() m_rdy(0x)/m_frame(0x). Probable Cause Indicates that wait cycles to recover the lost frame or credit is exceeded on the specified port.
C3-1017 Recommended Action Severity 12 Whenever this error is observed persistently, power cycle the specified blade. If the problem persists, replace the blade. ERROR C3-1017 Message , [C3-1017], ,, ERROR, , Blade in Slot failed due to unavailability of ports in the internal trunk. Probable Cause Indicates that the blade failed due to unavailability of the ports in the internal trunk.
12 C3-1021 Recommended Action Severity No action is required. WARNING C3-1021 Message , [C3-1021], ,, WARNING, , S,P(): Port offline due to Encryption Compression Block error. Probable Cause Indicates that an internal error is observed in the ASIC hardware that may degrade the data traffic. Recommended Action Whenever this error occurs, software recovers from the error. If the problem persists, replace the blade.
Chapter CAL System Messages 13 CAL-1001 Message , [CAL-1001], ,, INFO, , Switch offline requested by remote domain . Probable Cause Indicates a remote domain has requested the local domain to be disabled. Recommended Action See remote domain raslogs for the reason.
13 110 CAL-1001 Fabric OS Message Reference 53-1002448-01
Chapter CCFG System Messages 14 CCFG-1001 Message , [CCFG-1001], ,, ERROR, , Failed to initialize , rc = . Probable Cause Indicates that the initialization of a module within the Converged Enhanced Ethernet (CEE) configuration management daemon has failed. Recommended Action Download a new firmware version using the firmwareDownload command.
14 CCFG-1004 CCFG-1004 Message , [CCFG-1004], ,, ERROR, , Configuration replay failed due to missing system startup configuration file. Probable Cause Indicates that the startup configuration file has been moved or deleted and therefore replaying the system configuration has failed. Recommended Action Execute the copy file startup-config command to restore the startup configuration from any backup retrieved on the server.
CCFG-1008 14 CCFG-1008 Message , [CCFG-1008], ,, ERROR, , CMSH init failed: . Probable Cause Indicates that CEE Management Shell (CMSH) initialization has failed. Recommended Action No action is required. Severity ERROR CCFG-1009 Message , [CCFG-1009], ,, INFO, , Successfully copied to . Probable Cause Indicates that a configuration file has been copied to the specified destination.
14 CCFG-1012 CCFG-1012 Message , [CCFG-1012], ,, ERROR, , Blade in slot failed to reach ONLINE state within seconds after receiving system ready. Probable Cause Indicates that the blade in the specified slot has failed to come online within the specified timeout interval after receiving the system ready event. Recommended Action Execute the slotPowerOff and slotPowerOn commands on the specified slot to bring the blade online.
Chapter CDR System Messages 15 CDR-1001 Message , [CDR-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable between peer ports, or that the port speed configuration does not match the capability of the SFP. Recommended Action Ensure that you are using compatible SFPs on the peer ports.
15 CDR-1004 CDR-1004 Message , [CDR-1004], , ERROR, , S, C: Invalid DMA ch pointer, chan:, good_addr:0x, bad_addr:0x. Probable Cause Indicates an internal error in the Application Specific Integrated Circuit (ASIC) hardware that may degrade data traffic. Recommended Action Whenever this error occurs, restart the system at the next maintenance window. If the problem persists, replace the blade.
CDR-1008 Recommended Action Severity 15 No action is required. WARNING CDR-1008 Message , [CDR-1008], ,, WARNING, , S,C: HW ASIC Chip warning Level 1 type = 0x. Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic. Recommended Action Whenever this error occurs, restart the system at the next maintenance window.
15 CDR-1011 CDR-1011 Message , [CDR-1011], ,, WARNING, , S,P(): Link Timeout on internal port ftx= tov=(>) vc_no= crd(s)lost= complete_loss:. Probable Cause Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that port for two seconds.
CDR-1016 Recommended Action Severity 15 Whenever this error is observed persistently, power cycle the specified blade. If the problem persists, replace the blade. WARNING CDR-1016 Message , [CDR-1016], ,, ERROR, , Port is faulted due to port re-initialization failure on internal Port S,P() with reason . Probable Cause Indicates that port is faulted due to port re-initialization failure.
15 CDR-1019 Recommended Action Severity 120 Whenever this error occurs, restart the system at the next maintenance window.
Chapter CER System Messages 16 CER-1001 Message , [CER-1001], ,, ERROR, , HA Sync broken, since standby Advanced Performance Tuning module does not support FICON Management Server (FMS). Probable Cause Indicates that the high-availability (HA) synchronization between the active and standby control processors (CPs) is broken, because there is downlevel firmware loaded on the standby CP.
16 122 CER-1001 Fabric OS Message Reference 53-1002448-01
Chapter CHS System Messages 17 CHS-1002 Message , [CHS-1002], , FFDC, ERROR, , ki_gd_register_action failed with rc =. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the blade to recover the system. For a non-bladed system, execute the fastBoot command on the switch to recover the system.
17 CHS-1005 CHS-1005 Message , [CHS-1005], ,, ERROR, , Diag attach failed during recovery, disabling slot = . Probable Cause Indicates that the Diag blade attach has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command.
Chapter CNM System Messages 18 CNM-1001 Message , [CNM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR CNM-1002 Message , [CNM-1002], ,, ERROR, , Failed to initialize rc = .
18 CNM-1004 CNM-1004 Message , [CNM-1004], ,, INFO, , iSCSI service is on the switch. Probable Cause Indicates that the Crypto service is enabled or disabled on the switch. Recommended Action No action is required. Severity INFO CNM-1005 Message , [CNM-1005], ,, INFO, , Posting event CNM_EVT_GRP_LEADER_ELECTED Name [], WWN [].
CNM-1008 18 CNM-1008 Message , [CNM-1008], ,, INFO, , Posting event CNM_EVT_NODE_EJECT nodeName [], wwn []. Probable Cause Indicates that the node is ejected from the Encryption Group (EG). Recommended Action No action is required. Severity INFO CNM-1009 Message , [CNM-1009], ,, INFO, , Posting event CNM_EVT_STANDALONE_MODE. Probable Cause Indicates that the node is in standalone mode.
18 CNM-1012 CNM-1012 Message , [CNM-1012], ,, INFO, , Posting event CNM_EVT_EG_DELETED. Probable Cause Indicates that the Encryption Group (EG) is deleted. Recommended Action No action is required. Severity INFO CNM-1013 Message , [CNM-1013], ,, INFO, , Posting event GL Node Split condition, isolating peer GL node . Probable Cause Indicates that the Encryption Group (EG) is split.
CNM-1016 18 CNM-1016 Message , [CNM-1016], ,, INFO, ,Posting event Detected a EG degrade condition. Probable Cause Indicates an Encryption Group (EG) degrade condition. Recommended Action No action is required. Severity INFO CNM-1017 Message , [CNM-1017], ,, INFO, , Got JOIN REQUEST from un-recognized GL node [], configured GL node is [].
18 CNM-1020 CNM-1020 Message , [CNM-1020], ,, INFO, , Node Admission Control failed, due to mismatch in certificates, rejecting node []. Probable Cause Indicates that the Node Admission Control has failed. Recommended Action No action is required. Severity INFO CNM-1021 Message , [CNM-1021], ,, INFO, , Failed to sign the node authentication message, admission control might fail.
CNM-1024 18 CNM-1024 Message , [CNM-1024], ,, INFO, , Operation not required on GL node. Probable Cause Indicates an operation is not required on a group leader (GL) node. Recommended Action No action is required. Severity INFO CNM-1025 Message , [CNM-1025], ,, INFO, , Operation not allowed, as member is active with the Cluster. Eject member node and retry.
18 CNM-1028 CNM-1028 Message , [CNM-1028], ,, INFO, , Certfile already exists. No need to sync up. Probable Cause Indicates that the certificate file for the node already exists. Recommended Action No action is required. Severity INFO CNM-1029 Message , [CNM-1029], ,, WARNING, , Certfile content does not match the cert sent by GL.
CNM-1032 18 CNM-1032 Message , [CNM-1032], ,, WARNING, , Certfile size does not match cert file size sent by GL Probable Cause Indicates that there is a size mismatch between a node's certificate file and the certificate file received from the group leader. Recommended Action No action is required.
18 CNM-1036 CNM-1036 Message , [CNM-1036], ,, INFO, , All the active nodes of the cluster are in ONLINE state. Posting converged event. Probable Cause Indicates an event is being posted to indicate that the cluster is in a converged state. Recommended Action No action is required.
CNM-1040 18 CNM-1040 Message , [CNM-1040], ,, INFO, , Split-Brain Arbitration won, Majority WWN/GL Node, remote_wwn:local_wwn . Probable Cause Indicates that split arbitration is won. Recommended Action No action is required. Severity INFO CNM-1041 Message , [CNM-1041], ,, INFO, , Updating persistent Cluster DB, please avoid powering off the switch.
18 CNM-1044 CNM-1044 Message , [CNM-1044], ,, ERROR, , Cluster Create Failed as the Certificate files not found, Please do the initnode. Probable Cause Indicates that the initnode is not invoked. Recommended Action No action is required. Severity ERROR CNM-1045 Message , [CNM-1045], ,, ERROR, , Member node [] is having dual IP stack.Registering member node with dual IP in an EG with only IPV6 is not allowed.
CNM-1048 18 CNM-1048 Message , [CNM-1048], ,, INFO, , Posting . Probable Cause Indicates the event that is posted. Recommended Action No action is required. Severity INFO CNM-1049 Message , [CNM-1049], ,, ERROR, , Failed to define node, Node Name []. Probable Cause Indicates the system failed to define the node object. Recommended Action No action is required.
18 CNM-1052 CNM-1052 Message , [CNM-1052], ,, ERROR, , Member node registered with another Encryption Group. To proceed eject the member node from other EG. Probable Cause Indicates that the member node is registered with another Encryption Group (EG). Recommended Action No action is required. Severity ERROR CNM-1053 Message , [CNM-1053], ,, ERROR, , Node is already a registered member of another EG.
CNM-1056 18 CNM-1056 Message , [CNM-1056], ,, INFO, , Posting event CNM_EVT_EE_INITIALIZING Slot [], Wwn [], IP [], flags []. Probable Cause Indicates that the Encryption Engine (EE) is added into the Encryption Group (EG). Recommended Action No action is required.
18 CNM-1060 CNM-1060 Message , [CNM-1060], ,, INFO, , Local Node CP certificate pair mismatch detected. Probable Cause Indicates that the certificate pair is matched. Recommended Action No action is required. Severity INFO CNM-1061 Message , [CNM-1061], ,, INFO, , IP of the switch changed from [] to []. Probable Cause Indicates that the switch IP has changed.
CNM-3002 18 CNM-3002 Message , [CNM-3002], ,, INFO, , Event: cryptocfg Status: success, Info: encryption group deleted. Probable Cause Indicates an encryption group was deleted. Recommended Action No action is required. Severity INFO CNM-3003 Message , [CNM-3003],,, INFO, , Event: cryptocfg Status: success, Info: Membernode \\ added to encryption group.
18 CNM-3006 CNM-3006 Message , [CNM-3006], ,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat miss count set to . Probable Cause Indicates that the heartbeat miss value was set. Recommended Action No action is required. Severity INFO CNM-3007 Message , [CNM-3007],,, INFO, , Event: cryptocfg Status: success, Info: Heartbeat timeout set to .
CNM-3010 18 CNM-3010 Message , [CNM-3010],,, INFO, , Event: cryptocfg Status: success, Info: Membernode unregistered. Probable Cause Indicates a membernode was unregistered. Recommended Action No action is required. Severity INFO CNM-3011 Message , [CNM-3011], ,, INFO, , Event: cryptocfg Status: success, Info: Encryption group synchronized.
18 144 CNM-3012 Fabric OS Message Reference 53-1002448-01
Chapter CONF System Messages 19 CONF-1000 Message , [CONF-1000], , , INFO, , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The Info about the parameters and AD variable is the description of the classes of configuration parameters that were downloaded. If Admin Domain (AD) is enabled, the AD number is specified in the description.
19 CONF-1021 CONF-1021 Message , [CONF-1021], ,, INFO, , configUpload not permitted . Probable Cause Indicates a configUpload operation is not permitted. There are many possible causes. Recommended Action Execute the errShow command to view the error log. Correct the error and execute the configUpload command again.
CONF-1030 19 CONF-1030 Message , [CONF-1030], ,, WARNING, , Configuration database full, data not committed (key:. Probable Cause Indicates that the previous configuration commands have resulted in a database full condition. Configuration changes associated with the specified key have not been applied.
19 CONF-1041 CONF-1041 Message , [CONF-1041], ,, INFO, , configRemove failed. . Probable Cause Indicates that an error occurred while executing the configRemove command. Recommended Action Execute the errShow command to view the error log. Correct the error and execute the configRemove command again.
Chapter CTAP System Messages 20 CTAP-1001 Message , [CTAP-1001], ,, INFO, , Key acquisition for . Probable Cause Indicates that a change in the tape pool database has triggered the key acquisition process for each pool. Recommended Action Do not start tape backup or restore operations involving tape pools until the process is complete.
20 150 CTAP-1001 Fabric OS Message Reference 53-1002448-01
Chapter CVLC System Messages 21 CVLC-1001 Message , [CVLC-1001], ,, INFO, , re-key , LUN SN: . Container: , Initiator: , LUN ID: . Probable Cause Indicates the First time encryption, Key expired or Manual re-key operation is performed.
21 CVLC-1004 CVLC-1004 Message , [CVLC-1004], ,, INFO, , Forceful encryption LUN removal while re-key session is still active. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption LUN was forcefully removed while a re-key session was still active. Recommended Action No action is required.
CVLC-1008 Recommended Action 21 If you want to preserve the user data, use cryptocfg --modLUNpolicy -cleartext to convert to clear text LUN. Use cryptocfg ---modLUNpolicy -disable_allowdecrypt to disable decryption of existing data. Then try the LUN deletion again. Severity ERROR CVLC-1008 Message , [CVLC-1008], ,, ERROR, , LUN discovery failure: , Container: , Initiator: , LUN ID: .
21 CVLC-1011 CVLC-1011 Message , [CVLC-1011], ,, ERROR, , Third party license is required for encryption LUN in third party mode. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the encryption LUN is configured with non-Brocade mode but there is no valid license. Recommended Action Obtain license for non-Brocade mode.
CVLC-1014 21 CVLC-1014 Message , [CVLC-1014], ,, ERROR, , Missing Key ID from user input. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the data state in the LUN configuration is in the encrypted state without a key ID and there is no metadata found on the LUN. Recommended Action Use cryptocfg command to add the key ID, if available.
21 CVLC-1018 Recommended Action Severity No action is required. ERROR CVLC-1018 Message , [CVLC-1018], ,, INFO, , Event: . Container: , Initiator: , LUN ID: . Probable Cause Indicates an informational event. Recommended Action No action is required.
CVLC-1021 21 CVLC-1021 Message , [CVLC-1021], ,, INFO, , User provided key ID is ignored while metadata exists. Container: , Initiator: , LUN ID: . Probable Cause Indicates that the key ID provided is ignored because metadata exists on the LUN. Recommended Action No action is required.
21 CVLC-1025 Recommended Action Severity No action is required. INFO CVLC-1025 Message , [CVLC-1025], ,, ERROR, , Secondary Metadata exists for encrypted LUN not configured with -newLUN option . Container: , Initiator: , LUN ID: . Probable Cause Indicates that the secondary metadata exists on the LUN that is not configured with --newLUN option.
CVLC-1028 21 CVLC-1028 Message , [CVLC-1028], ,, WARNING, , Not starting auto rekey on LUN with uncompressible blocks 1-16. Container: , Initiator: , LUN ID: . Probable Cause Indicates a warning event. Recommended Action Perform a manual rekey on this LUN.
21 CVLC-1031 CVLC-1031 Message , [CVLC-1031], ,, WARNING, , Primary LUN is restored from mirror LUN. LUN in read-only mode. Container: , Initiator: , LUN ID: . Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing. Recommended Action 1. Create a new primary LUN. 2. Add it to its container with -newLUN option. 3.
CVLC-1035 Recommended Action Severity 21 No action is required. INFO CVLC-1035 Message , [CVLC-1035], ,, ERROR, , A decommissioned LUN has been added back as encrypted LUN. Container , Initiator: , LUN ID: . Probable Cause Indicates that decommissioned LUN has been added back as encrypted LUN. Recommended Action 1. Remove LUN from container. 2. Add it back as a cleartext LUN. 3.
21 162 CVLC-1041 Fabric OS Message Reference 53-1002448-01
Chapter CVLM System Messages 22 CVLM-1001 Message , [CVLM-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Restart or power cycle the switch.
22 CVLM-1004 CVLM-1004 Message , [CVLM-1004], ,, WARNING, , Crypto device configuration between local switch () and peer () is out of sync. New encryption session is not allowed. Probable Cause Indicates that EE nodes in the cluster encryption group have different configurations. Recommended Action Synchronize the configuration in the cluster group using the cryptocfg --commit command.
CVLM-1008 22 CVLM-1008 Message , [CVLM-1008], ,, WARNING, , The member () of HAC () is not in the fabric. Probable Cause Indicates that the member of HAC is not in the fabric. Recommended Action Check the ISL port connected to the fabric. Severity WARNING CVLM-1009 Message , [CVLM-1009], ,, INFO, , The member () of HAC () is in the fabric.
22 CVLM-1012 CVLM-1012 Message , [CVLM-1012], ,, INFO, , The HAC failback occurs at EE ( ). Probable Cause Indicates that the HAC failback occurs at the EE. Recommended Action No action is required. Severity INFO CVLM-3001 Message , [CVLM-3001], ,, INFO, , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates the failback mode was set.
CVLM-3004 22 CVLM-3004 Message , [CVLM-3004], ,, INFO, , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Probable Cause Indicates an HA cluster member was added to an HA cluster. Recommended Action No action is required. Severity INFO CVLM-3005 Message , [CVLM-3005], ,, INFO, , Event: cryptocfg Status: success, Info: Cluster member removed from HA cluster .
22 CVLM-3008 Recommended Action Severity No action is required. INFO CVLM-3008 Message , [CVLM-3008],,, INFO, , Event: cryptocfg Status: success, Info: Container \\ deleted. Probable Cause Indicates a cryptotarget container was deleted. Recommended Action No action is required.
CVLM-3012 Recommended Action Severity 22 No action is required. INFO CVLM-3012 Message , [CVLM-3012],,, INFO, , Event: cryptocfg Status: success, Info: Initiator \\ removed from crypto target container \\. Probable Cause Indicates an initiator was removed from a cryptotarget container. Recommended Action No action is required.
22 CVLM-3015 CVLM-3015 Message , [CVLM-3015], ,, INFO, , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, removed from crypto target container \\. Probable Cause Indicates a LUN was removed from a cryptotarget container. Recommended Action No action is required.
CVLM-3019 22 CVLM-3019 Message , [CVLM-3019], ,, INFO, , Event: cryptocfg Status: success, Info: Tape pool \\ modified. Probable Cause Indicates a tapepool was modified. Recommended Action No action is required.
22 CVLM-3023 CVLM-3023 Message , [CVLM-3023], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction committed. Probable Cause Indicates a transaction commit operation was performed. Recommended Action No action is required. Severity INFO CVLM-3024 Message , [CVLM-3024], ,, INFO, , Event: cryptocfg Status: success, Info: Transaction aborted.
CVLM-3027 22 CVLM-3027 Message , [CVLM-3027], ,, INFO, , Event: cryptocfg Status: success, Info: Decommission of device (container initiator , LUN ). Probable Cause Indicates that the decommission operation has been completed for the device. Recommended Action No action is required.
22 174 CVLM-3028 Fabric OS Message Reference 53-1002448-01
Chapter DAUTH System Messages 23 DOT1-1001 Message , [DOT1-1001], ,, INFO, 802.1X is enabled globally. Probable Cause Indicates that 802.1X is enabled globally. Recommended Action No action is required. Severity INFO DOT1-1002 Message , [DOT1-1002], ,, INFO, 802.1X is disabled globally. Probable Cause Indicates that 802.1X is disabled globally. Recommended Action No action is required.
23 DOT1-1005 Recommended Action Severity No action is required. INFO DOT1-1005 Message , [DOT1-1005], ,, INFO, 802.1X authentication is successful on port . Probable Cause Indicates that authentication has succeeded on the specified port. Recommended Action No action is required. Severity INFO DOT1-1006 Message , [DOT1-1006], ,, WARNING, 802.1X authentication has failed on port .
DOT1-1009 Recommended Action Severity 23 No action is required. INFO DOT1-1009 Message , [DOT1-1009], ,, INFO, 802.1X is disabled for port . Probable Cause Indicates that 802.1X is disabled for a specified port. Recommended Action No action is required. Severity INFO DOT1-1010 Message , [DOT1-1010], ,, INFO, Port is set in auto mode. Probable Cause Indicates that the port is set to auto mode.
23 178 DOT1-1010 Fabric OS Message Reference 53-1002448-01
Chapter ECC System Messages 24 ECC-1000 Message , [ECC-1000], ,, ERROR, , ECC Error occurrence of . Probable Cause Indicates that the processor memory controller has detected one of several types of DDR memory errors.
24 180 ECC-1001 Fabric OS Message Reference 53-1002448-01
Chapter EM System Messages 25 EM-1001 Message , [EM-1001], , FFDC, CRITICAL, , is overheating: Shutting down. Probable Cause Indicates that the specified field-replaceable unit (FRU) is shutting down due to overheating. This event is typically due to a faulty fan and can also be caused by the switch environment. Recommended Action Verify that the location temperature is within the operational range of the switch.
25 EM-1004 Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. On the Brocade 24000 and 48000, replace the specified FRU. For the Brocade 3900, replace the motherboard FRU.
EM-1006 25 EM-1006 Message , [EM-1006], , FFDC, CRITICAL, , has faulted. Sensors below minimum limits. Probable Cause Indicates that the sensors show the voltage is below minimum limits. The switch or specified blade is being shut down for environmental reasons; the voltage is too low. Recommended Action If this problem occurs on a blade, it usually indicates a hardware problem on the blade; replace the blade.
25 EM-1009 EM-1009 Message , [EM-1009], , FFDC, CRITICAL, , powered down unexpectedly. Probable Cause Indicates that the environmental monitor (EM) received an unexpected power-down notification from the specified field-replaceable unit (FRU). This may indicate a hardware malfunction in the FRU. Recommended Action Reseat the FRU. If the problem persists, replace the FRU.
EM-1013 Recommended Action 25 Reseat the specified field-replaceable unit (FRU). If the problem persists, restart or power cycle the switch. Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware problems. If the problem still persists, replace the FRU.
25 EM-1016 EM-1016 Message , [EM-1016], ,, WARNING, , Cold recovery failed (). Probable Cause Indicates that a problem was discovered when performing consistency checks during a cold boot. Recommended Action Monitor the switch. Severity If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider.
EM-1028 Recommended Action Severity 25 Execute the fosconfig --enable ethsw command to allow the blade to be up. Note that this is a disruptive command, which requires the system to be restarted. Otherwise, remove the blade. ERROR EM-1028 Message Probable Cause , [EM-1028], , FFDC, WARNING, , HIL Error: failed to access history log for FRU: (rc=).
25 EM-1033 Recommended Action Severity Close the ejector switch (raise the slider in most blades, or completely screw in the upper thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer to the appropriate Hardware Refernce Manual for instructions on inserting the switch blades. ERROR EM-1033 Message , [EM-1033], ,, ERROR, , CP in set to faulty because CP ERROR asserted.
EM-1035 25 EM-1035 Message Probable Cause , [EM-1035], ,, ERROR, , 2 circuit paired Power Supplies are faulty, please check the AC main switch/circuit to see if it has power. Indicates that both power supplies associated with one of the two main circuits are present but faulty, may be the circuit's switch has been turned off, or the AC power source has been interrupted for that circuit.
25 EM-1042 Recommended Action Severity No action is required. INFO EM-1042 Message , [EM-1042], ,, WARNING, , Important FRU header data for is not valid). Probable Cause Indicates that the specified field-replaceable unit (FRU) has an incorrect number of sensors in its FRU header-derived information. This could mean that the FRU header was corrupted or read incorrectly, or corrupted in the object database, which contains information about all FRUs.
EM-1045 25 EM-1045 Message Probable Cause , [EM-1045], ,, WARNING, , is being powered . Indicates that an automatic power adjustment is being made because of the (predicted) failure of a power supply or the insertion or removal of a port blade. The new state value can be one of the following: • On - A port blade is being powered on because the power is available (a power supply was inserted or a port blade was removed or powered down).
25 EM-1048 Recommended Action Severity No action is required. INFO EM-1048 Message , [EM-1048], ,, INFO, , I2C access recovered: state Probable Cause Indicates that the Inter-Integrated Circuit (I2C) bus problems have been resolved and I2C access to the field-replaceable unit (FRU) has become available again. Recommended Action No action is required. The EM-1048 message is displayed when the EM-1029 error is resolved.
EM-1051 25 EM-1051 Message , [EM-1051], ,, INFO, , : Inconsistency detected, FRU reinitialized. Probable Cause Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the state of the FRU was changing during a failover. The FRU is reinitialized and the traffic may have been disrupted. Recommended Action No action is required.
25 EM-1059 EM-1059 Message , [EM-1059], , FFDC, ERROR, , with ID may not be supported on this platform, check FOS firmware version as a possible cause. Probable Cause Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is incompatible with the switch configuration software. The system may not be usable. The blade may only be supported by a later (or earlier) version of the firmware.
EM-1062 25 EM-1062 Message , [EM-1062], ,, CRITICAL, , Blade in slot faulted as it exceeds the maximum support limit of blades with Blade ID in the chassis. Probable Cause Indicates that too many blades of a particular type are in the system. Recommended Action Remove the faulted blade.
25 EM-1066 Recommended Action Severity Upgrade the Fabric OS firmware or the SAS firmware using the firmwareDownload command. Refer to the release notes for a compatible version of firmware. WARNING EM-1066 Message , [EM-1066], ,, INFO, , SAS Virtualization Services are now available .
EM-1069 Recommended Action Severity 25 Restart or power cycle the switch. If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. ERROR EM-1069 Message , [EM-1069], ,, INFO, , Slot is being powered off. Probable Cause Indicates that the blade in the specified slot is being intentionally powered off.
25 EM-2003 EM-2003 Message , [EM-2003], ,, ERROR, , has failed the POST tests. FRU is being faulted. Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test (POST). Refer to the /tmp/post[1/2].slot#.log file for more information on the faults. To view this log file you must be logged in at the root level. The ID will be Switch for nonbladed systems.
Chapter ESS System Messages 26 ESS-1001 Message , [ESS-1001], ,, WARNING, , A few switches in the fabric do not support the Coordinated HotCode protocol. Probable Cause Indicates one or more switches in the fabric do not support the Coordinated HotCode protocol. Continuing with the firmware download may cause data traffic disruption.
26 ESS-1004 ESS-1004 Message , [ESS-1004], ,, WARNING, , The resume message is rejected by the domain . Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the resume message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected resume message. Recommended Action No action is required.
ESS-1010 Recommended Action Severity 26 Select an appropriate fabric name and set it again from any switch. WARNING ESS-1010 Message , [ESS-1010], ,, WARNING, , Duplicate Fabric Name - matching with FID . Probable Cause Indicates that the configured fabric name is already used for another partition. Recommended Action Select a different fabric name and reconfigure.
26 202 ESS-1010 Fabric OS Message Reference 53-1002448-01
Chapter ESWCH System Messages 27 ESW-1001 Message , [ESW-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates that the switch enable has failed. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
27 ESW-1004 ESW-1004 Message , [ESW-1004], ,, ERROR, ,Blade attach failed during recovery, disabling slot = . Probable Cause Indicates that the blade has failed during failover or recovery. Recommended Action On a Brocade 8000 switch, restart or power cycle the switch. Severity ERROR ESW-1005 Message , [ESW-1005], ,, ERROR, ,Diag attach failed during recovery, disabling slot = .
ESW-1008 Recommended Action Severity 27 Based on the disable reason displayed, take appropriate action to restore the port. Insufficient frame buffers: Reduce the distance or speed settings for the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be disabled to make more buffers available for the link. Refer to the Fabric OS Administrator's Guide for more information.
27 206 ESW-1008 Fabric OS Message Reference 53-1002448-01
Chapter EVMD System Messages 28 EVMD-1001 Message , [EVMD-1001], ,, WARNING, , Event could not be sent to remote proxy. = . Probable Cause Indicates the event could not be sent to remote proxy. This could happen if the remote proxy switch cannot be reached through in-band. The event could not be sent to the remote proxy because the remote proxy switch cannot be reached through in-band.
28 208 EVMD-1001 Fabric OS Message Reference 53-1002448-01
Chapter FABR System Messages 29 FABR-1001 Message , [FABR-1001], ,, WARNING, , port , . Probable Cause Indicates that the specified switch port is isolated because of a segmentation resulting from mismatched configuration parameters. Recommended Action Based on the segmentation reason displayed within the message, look for a possible mismatch of relevant configuration parameters in the switches at both ends of the link.
29 FABR-1004 Run the fabStateShow command on both the receiving and transmitting switches. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
FABR-1007 Recommended Action 29 In case of severe memory corruption, the system might recover by performing an automatic failover. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity WARNING FABR-1007 Message , [FABR-1007], ,, WARNING, , IU free error, caller: .
29 FABR-1010 Recommended Action Severity The fabric daemon will discard the EFP. The system will recover through the EFP retrial process. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING FABR-1010 Message , [FABR-1010], ,, WARNING, , .
FABR-1013 29 FABR-1013 Message , [FABR-1013], , FFDC, CRITICAL, , No Memory: pid= file=
29 FABR-1016 FABR-1016 Message , [FABR-1016], ,, WARNING, , ficonMode is enabled. Probable Cause Indicates that FICON mode is enabled on the switch through a user interface command. Recommended Action No action is required. Severity WARNING FABR-1017 Message , [FABR-1017], ,, WARNING, , ficonMode is disabled. Probable Cause Indicates that FICON mode is disabled on the switch through a user interface command.
FABR-1019 29 FABR-1019 Message , [FABR-1019], , FFDC, CRITICAL, , Critical fabric size () exceeds supported configuration (). Probable Cause Indicates that this switch is a value-line switch and has exceeded the limited fabric size: that is, a specified limit to the number of domains. This limit is defined by your specific value-line license key.
29 FABR-1022 FABR-1022 Message , [FABR-1022], , FFDC, CRITICAL, , Fabric size () exceeds supported configuration (). Fabric limit timer () started from . Probable Cause Indicates that the fabric size has exceeded the value-line limit, and the grace period counter has started. If the grace period is complete and the size of the fabric is still outside the specified limit, Web Tools is disabled.
FABR-1029 29 FABR-1029 Message , [FABR-1029], ,, INFO, , Port negotiated (mode = ). Probable Cause Indicates that a different flow control mode, as described in the message, is negotiated with the port at the other end of the link. The flow control is a mechanism of throttling the transmitter port to avoid buffer overrun at the receiving port.
29 FABR-1032 FABR-1032 Message , [FABR-1032], , WARNING, , Remote switch with domain ID and switchname running an unsupported FOS version v2.x has joined the fabric. Probable Cause Indicates that a switch with an unsupported Fabric OS version 2.x has joined the fabric. Recommended Action Remove the switch with the unsupported Fabric OS version 2.x from the fabric.
FABR-1037 Recommended Action Severity 29 Move the cable to a port that does not have Trunk Area enabled. INFO FABR-1037 Message , [FABR-1037], , INFO, , Port configuration incompatible with Trunk Area enabled port. Persistently disabling port .
29 FABR-1040 FABR-1040 Message , [FABR-1040], , INFO, , Speed is not 2g,4g or 8g with F_port trunking enabled. Persistently disabling port . Probable Cause Indicates that the speed is not compatible for F_port trunks. Recommended Action Change the speed for the port or disable F_port trunking on the port.
FABR-1044 29 FABR-1044 Message , [FABR-1044], , ERROR, , Detected Fabric ID conflict with neighbor switch (domain ), FID . E-ports () connected to the switch are disabled. Probable Cause Indicates that the neighbor switch has a Fabric ID conflict with the local switch. All E_ports directly connected to the conflicting switch are disabled.
29 FABR-1047 FABR-1047 Message , [FABR-1047], , INFO, , Area unavailable to assign to the port. Persistently disabling port . Probable Cause Indicates that there are no areas available to assign to the port during port creation. Recommended Action Move some ports out of the default switch to make areas available.
FABR-1051 Recommended Action Severity 29 Install the required license. INFO FABR-1051 Message Probable Cause , [FABR-1051], ,, ERROR, , D-Port loopback test failed for slot and port . Indicates that the D-Port test failed for the given slot and port due to one of the following reasons: • The SFP fault detected by Electrical loopback test failure. • The cable fault detected by optical loopback test failure.
29 FABR-1054 FABR-1054 Message , [FABR-1054], , FFDC, INFO, , Rebooting the standby as it received an update before port [] is expanded. Probable Cause Indicates that the standby CP did not have the port because the port expand operation is still in progress and the standby CP has received a port update. The standby CP reboots automatically to ensure sync and attain normal state. This is a rare occurrence. Recommended Action No action is required.
Chapter FABS System Messages 30 FABS-1001 Message , [FABS-1001], , FFDC, CRITICAL, , Probable Cause Indicates that the system is low on memory and cannot allocate more memory for new operations. This is usually an internal Fabric OS problem or file corruption. Description of memory need indicates how much memory was being requested. The value could be any whole number.
30 FABS-1005 FABS-1005 Message Probable Cause , [FABS-1005], ,, WARNING, , (= ) Indicates that an unsupported operation has been requested. This is usually an internal Fabric OS problem or file corruption. The possible value for function name and description of problem is: fabsys_write: Unsupported write operation: process xxx where xxx is the process ID (PID), which could be any whole number.
FABS-1008 30 If the message persists, run the firmwareDownload command to update the firmware. Severity WARNING FABS-1008 Message , [FABS-1008], ,, WARNING, , : Media oid mapping failed Probable Cause Indicates that the Fabric OS was unable to locate a necessary object handle. This is usually an internal Fabric OS problem or file corruption. Recommended Action Reboot or power cycle the switch.
30 FABS-1013 Recommended Action Severity Reboot or power-cycle the CP or system. If the message persists, run the firmwareDownload command to update the firmware. ERROR FABS-1013 Message Probable Cause , [FABS-1013], ,, ERROR, , []:Unknown blade type 0x Indicates an unrecognized type of blade has been discovered in the system.
FABS-1015 30 If the message persists, run the firmwareDownload command to update the firmware.
30 230 FABS-1015 Fabric OS Message Reference 53-1002448-01
Chapter FBC System Messages 31 FBC-1001 Message , [FBC-1001], ,, ERROR, , Firmware version on AP blade is incompatible with that on the CP. Probable Cause The CP determined that the version of firmware running on the AP blade is not compatible with the version of firmware running on the CP. The AP and CP blades cannot communicate. Recommended Action The problem can be corrected by changing the version of firmware on the CP or AP blades.
31 232 FBC-1001 Fabric OS Message Reference 53-1002448-01
Chapter FCIP System Messages 32 FCIP-1000 Message , [FCIP-1000], , FFDC, ERROR, , of GE failed. Please retry the command. Data: inst= st= rsn= fn= oid= Probable Cause Indicates that the hardware is not responding to a command request, possibly because it is busy. Recommended Action Retry the command.
32 FCIP-1003 FCIP-1003 Message , [FCIP-1003], , INFO, , An IPsec/IKE policy was deleted. Probable Cause Indicates that an IPsec/IKE policy was deleted and the config file was updated. Recommended Action No action is required. Severity INFO FCIP-1004 Message , [FCIP-1004], ,, INFO, , Tape Read Pipelining is being disabled slot () port () tunnel ().
Chapter FCMC System Messages 33 FCMC-1001 Message , [FCMC-1001], , FFDC, CRITICAL, , System is low on memory and has failed to allocate new memory. Probable Cause Indicates that the switch is low on memory and failed to allocate new memory for an information unit (IU). Recommended Action A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically fail over and the standby CP will become the active CP.
33 236 FCMC-1001 Fabric OS Message Reference 53-1002448-01
Chapter FCOE System Messages 34 FCOE-1001 Message , [FCOE-1001], ,, ERROR, , calloc failed for
34 FCOE-1005 Recommended Action Severity Remove the failed member from the logingroup. ERROR FCOE-1005 Message , [FCOE-1005], ,, ERROR, , : membership check failed in logingroup: Probable Cause Indicates that the Membership check for the device has failed. Recommended Action Check the device for failed Membership.
FCOE-1010 Recommended Action Severity 34 Remove unwanted nport mappings and try adding nport mapping. INFO FCOE-1010 Message , [FCOE-1010], ,, ERROR, , Cleanup of login failed for port:. Probable Cause Indicates an invalid port number. Recommended Action Use the supportsave command and restart the system.
34 FCOE-1015 Recommended Action Severity Request to add ports to VLAN failed. ERROR FCOE-1015 Message , [FCOE-1015], ,, ERROR, , Request to add MACs to Layer 2 for ifindex 0xx failed, rc:. Probable Cause Indicates that an add request to Layer 2 for slot or port has failed. Recommended Action Request to add MACs to Layer 2 for slot or port failed.
FCOE-1019 Recommended Action Severity 34 Request to delete MACs from Layer 2 for slot or port failed. ERROR FCOE-1019 Message , [FCOE-1019], ,, WARNING, , FLOGI ignored as FC-MAP not configured on FCOE VLAN. Probable Cause Indicates that the FC-MAP has not been configured on FCOE VLAN. Recommended Action Configure FC-MAP on FCOE VLAN.
34 FCOE-1024 Recommended Action Severity No action is required. WARNING FCOE-1024 Message , [FCOE-1024], ,, WARNING, , FDISC received from Enode without prior FLOGI. Probable Cause Indicates that no root Nport has logged in. Recommended Action No action is required. Severity WARNING FCOE-1025 Message , [FCOE-1025], ,, WARNING, , FCOE logout received on FIP VN port.
FCOE-1028 Recommended Action Severity 34 No action is required. ERROR FCOE-1028 Message , [FCOE-1028], ,, ERROR, , : . Probable Cause Indicates the FCoE device with following WWN is not a member of the login group: WWN will be printed. Recommended Action Change the FCoE login group policy on the switch for the device to login.
34 FCOE-1032 Recommended Action Severity No action is required. WARNING FCOE-1032 Message , [FCOE-1032], ,, WARNING, , We are in WARM RECOVERING state. Probable Cause Indicates that a HA failover or reboot may be in progress. Recommended Action No action is required. Severity WARNING FCOE-1033 Message , [FCOE-1033], ,, WARNING, , FIP v1 FLOGI received - VF port in use.
FCOE-1038 Recommended Action Severity 34 Create a logingroup for the switch WWN with another name that will not lead to a name conflict. WARNING FCOE-1038 Message , [FCOE-1038], ,, INFO, , logingroup# ()created. Probable Cause Indicates that the logingroup is added in the switch logingroup table. Recommended Action No action is required.
34 FCOE-1042 Recommended Action Severity No action is required. INFO FCOE-1042 Message , [FCOE-1042], ,, INFO, , FCoE login configuration transaction saved fabric-wide. Probable Cause Indicates that the FCoE login configuration transaction is saved fabric-wide. Recommended Action No action is required. Severity INFO FCOE-1043 Message , [FCOE-1043], ,, INFO, , FCoE login configuration management disabled.
FCOE-1046 Recommended Action Severity 34 No action is required. INFO FCOE-1046 Message , [FCOE-1046], ,, INFO, , fcoed.conf file is truncated. Please reconfigure FCoE ports. Probable Cause Indicates the magic number in the fcoed.conf file does not match. The fcoed.conf file is truncated and updated with a new magic number. Recommended Action Reconfigure the FCoE ports as all the port configurations will be lost.
34 248 FCOE-1048 Fabric OS Message Reference 53-1002448-01
Chapter FCPD System Messages 35 FCPD-1001 Message Probable Cause , [FCPD-1001], ,, WARNING, , Probing failed on . Indicates that a Fibre Channel Protocol (FCP) switch probed devices on a loop port, and probing failed on the L_Port, AL_PA address, or the F_Port. For the AL_PA, the valid range is 00 through FF.
35 250 FCPD-1003 Fabric OS Message Reference 53-1002448-01
Chapter FCPH System Messages 36 FCPH-1001 Message Probable Cause , [FCPH-1001], , FFDC, CRITICAL, , : failed, out of memory condition Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver instance. The function can only be " fc_create". This function creates a Fibre Channel driver instance. The failed function call kmalloc_wrapper has failed.
36 FCPH-1004 Recommended Action Severity No action is required. WARNING FCPH-1004 Message , [FCPH-1004], ,, WARNING, , NPIV port has same Port WWN with old port with pid 0x as part of duplicate Port WWN detection policy. Probable Cause Indicates that this port is older port of same port name of NPV device. Recommended Action No action is required.
Chapter FCR System Messages 37 FCR-1001 Message , [FCR-1001], ,, INFO, , FC router proxy device in edge created at port . Probable Cause Indicates that a proxy device at the port in the edge fabric has been imported at the specified port. Recommended Action No action is required. Severity INFO FCR-1002 Message , [FCR-1002], ,, INFO, , FC router proxy device in edge deleted at port .
37 FCR-1005 Recommended Action Severity Verify that the devices were intended to be taken offline. If not, verify that the devices are functioning properly. Verify that all small form-factor pluggables (SFPs) are seated correctly. Check for faulty cables, deteriorated SFPs, or dirty connections. Replace the cables and SFPs if necessary. INFO FCR-1005 Message , [FCR-1005], ,, INFO, , FC router LSAN zone device removed at port .
FCR-1008 37 FCR-1008 Message , [FCR-1008], ,, INFO, , FC router LSAN zone created at port . Probable Cause Indicates that a logical storage area network (LSAN) zone was created at the specified port in the edge fabric. Recommended Action No action is required. Severity INFO FCR-1009 Message , [FCR-1009], ,, INFO, , FC router LSAN zone enabled at port : .
37 FCR-1012 Recommended Action Severity No action is required. INFO FCR-1012 Message , [FCR-1012], ,, INFO, , FC Router fabric build completed on port . Probable Cause Indicates that the fibre channel router has completed a fabric build at the specified port. Recommended Action No action is required.
FCR-1016 37 FCR-1016 Message , [FCR-1016], ,, INFO, , FCR fabric no longer reachable at port id () fabric ID . Probable Cause Indicates that a fabric is no longer accessible through the backbone fabric. This may be caused by a link or switch failure. Recommended Action No action is required.
37 FCR-1020 FCR-1020 Message , [FCR-1020], ,, WARNING, , Local LSAN zone entries for FC router exhausted; max limit: . Probable Cause Indicates that the number of logical storage area network (LSAN) zones created within a MetaSAN exceeds the local LSAN zone database limitations. Recommended Action Remove excess LSAN zones so that the number of LSAN zones created is within the range of local database limitations.
FCR-1023 37 FCR-1023 Message , [FCR-1023], ,, WARNING, , Local phantom port WWN entries exhausted. Probable Cause Indicates that the number of port world wide names (WWNs) in use exceeds the local port WWN resources. Recommended Action Limit the number of port WWNs required by limiting the remote edge fabric connectivity (which limits the number of translate domains).
37 FCR-1027 Recommended Action It is unlikely that WWN conflicts will occur as a result of pool rollover unless the switch is deployed in a very large MetaSAN environment with large number of logical storage area network (LSAN) devices and fabrics, or there are highly dynamic changes to EX_Port connectivity. WWN conflicts might cause unpredictable behavior in management applications.
FCR-1029 37 FCR-1029 Message , [FCR-1029], ,, INFO, , In slot port WWN pool 95 percent allocated. Probable Cause Indicates that the Port world wide name (WWN) pool has rolled over in the specified slot, and WWN entries detected not in use are reused as needed.
37 FCR-1033 Recommended Action Severity No action is required. INFO FCR-1033 Message , [FCR-1033], ,, INFO, , Edge fabric disabled security on port in fabric . Probable Cause Indicates that Secure mode was turned off in the edge fabric. Recommended Action No action is required. Severity INFO FCR-1034 Message , [FCR-1034], ,, INFO, , LSAN zone added in backbone fabric.
FCR-1037 Recommended Action Severity 37 No action is required. INFO FCR-1037 Message , [FCR-1037], ,, INFO, , LSAN zone disabled in the backbone fabric. Probable Cause Indicates that a logical storage area network (LSAN) zone is disabled in the backbone fabric. Recommended Action No action is required.
37 FCR-1040 FCR-1040 Message , [FCR-1040], ,, INFO, , Proxy device deleted in the backbone fabric. Probable Cause Indicates that a proxy device created in the backbone fabric was deleted. Recommended Action No action is required. Severity INFO FCR-1041 Message , [FCR-1041], ,, INFO, , LSAN zone device removed in the backbone fabric.
FCR-1048 37 FCR-1048 Message , [FCR-1048], ,, ERROR, , On EX port () setting port credits failed. Probable Cause Indicates that the specified credit type was not set. Recommended Action Setting port credits failed. Execute the portEnable command. If the problem persists try restarting the switch. If the message persists, collect switch information using the supportShow command, and contact your switch service provider.
37 FCR-1055 Recommended Action Check the error message log on the other switch using the errShow command for additional messages. Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or SFP if necessary. Run the portLogDumpPort command on both the receiving and transmitting port. Run the fabStateShow command on the transmitting switch. If the message persists, collect switch information using the supportShow command, and contact your switch service provider.
FCR-1058 37 Investigate the other switch for more details. Run the errShow command on the other switch to view the error log for additional messages. Severity ERROR FCR-1058 Message , [FCR-1058], ,, WARNING, , Port isolated due to mismatched configuration parameter; .
37 FCR-1061 VC_RDY mode: Virtual-channel flow control mode. This is a proprietary protocol. R_RDY mode: Receiver-ready flow control mode. This is the Fibre Channel standard protocol, that uses R_RDY primitive for flow control. Severity WARNING FCR-1061 Message , [FCR-1061], ,, INFO, , Backbone fabric created on port . Probable Cause Indicates that a backbone fabric was built on the specified port. Recommended Action No action is required.
FCR-1064 37 FCR-1064 Message , [FCR-1064], ,, ERROR, , Fabric ID of backbone FC-Routers mismatch or overlap. Probable Cause Indicates that either (1) a backbone fabric split and both are connected to common edge fabrics, or (2) the fabric IDs of two backbone fabrics connected to an edge fabric are the same. Recommended Action If the backbone fabric split, merge the fabrics.
37 FCR-1068 The limit includes both active and configured information that is part of the zoning database in the edge fabric. Non-LSAN zones are not counted in the limit. Recommended Action Severity Limit the logical storage area network (LSAN) zoning related zone configuration in the edge fabric connected to this port. WARNING FCR-1068 Message , [FCR-1068], ,, INFO, , The FC Routing service is disabled.
FCR-1071 37 FCR-1071 Message , [FCR-1071], ,, INFO, , Port is changed from non FCR port to FCR port. Probable Cause Indicates that the port became an EX_Port or VEX_Port. Recommended Action No action is required. Severity INFO FCR-1072 Message , [FCR-1072], ,, INFO, , Port is changed from FCR port to non FCR port.
37 FCR-1075 Recommended Action Severity Keep the number of LSAN Zones to the lower limit of the two CPs or upgrade the remote CP. ERROR FCR-1075 Message Probable Cause , [FCR-1075], ,, ERROR, , Zone Name configuration is larger than characters in the edge fabric connected to port . Indicates that the zone name configuration size created in the connected fabric exceeds the maximum supported by the FC Router.
FCR-1078 Recommended Action Severity 37 Ensure that the M-Model switch has the same currently configured details such as front port domain ID and WWN of the EX_Port on which this operation was attempted. WARNING FCR-1078 Message , [FCR-1078], ,, WARNING, , LSAN name is too long. It is dropped. Probable Cause Indicates that the length of the LSAN name exceeds the limit of 64 characters.
37 FCR-1081 FCR-1081 Message , [FCR-1081], ,, WARNING, , The pause message is rejected by the domain . Probable Cause Indicates that during the Coordinated HotCode protocol, a switch in the fabric has rejected the pause message which prevented the protocol from completing. Any data traffic disruption observed during the firmware download may have been due to the rejected pause message. Recommended Action No action is required.
FCR-1085 Recommended Action Severity 37 No action is required. WARNING FCR-1085 Message , [FCR-1085], ,, ERROR, , HA sync lost as remote CP does not support FCR based matrix. Probable Cause Indicates that the remote control processor (CP) has earlier firmware, which does not support the FCR- based matrix while the local CP has the feature enabled. This is causing the loss of the high-availability (HA) synchronization.
37 FCR-1088 FCR-1088 Message , [FCR-1088], ,, INFO, , LSAN tag added. Probable Cause Indicates that the user has added a LSAN tag. Recommended Action No action is required. Severity INFO FCR-1089 Message , [FCR-1089], ,, INFO, , LSAN tag removed. Probable Cause Indicates that the user has added a LSAN tag. Recommended Action No action is required.
FCR-1093 37 FCR-1093 Message , [FCR-1093], ,, INFO, , Slave EX-Port interopmode conflicts with trunk master . Disabling the port. Probable Cause Indicates that the slave EX-Port is disabled due to interop conflict with trunk master. Recommended Action Configure slave EX-Port with the trunk master interopmode.
37 278 FCR-1094 Fabric OS Message Reference 53-1002448-01
Chapter FICON System Messages 38 The FICON messages in this chapter include in many of the messages. The FICON Path is a string that includes, VEHDHPDDDPLPCUDV where: • VE - VE Port Number: This number represents the FCIP Tunnel number through its VE Port number. • HD - Host switch Domain number: This is a 1 byte hexidecimal value that represents the domain of the switch that the FICON Channel is directly connected to.
38 FICN-1004 FICN-1004 Message , [FICN-1004], ,, WARNING, , FICON XRC Emulation License Key is not installed. Probable Cause Indicates FICON eXtended Remote Copy (XRC) Emulation requires a license key. Recommended Action Use the appropriate license key.
FICN-1007 38 FICN-1007 Message , [FICN-1007], ,, ERROR, , DevDiskEgr:FICON Selective Reset:Path= State=0x stat_array=0x. Probable Cause Indicates that a Selective Reset from the channel was received as normal part of path recovery or starting sequence in an error case.
38 FICN-1010 FICN-1010 Message , [FICN-1010], ,, INFO, , DevDiskEgr:Device level exception flag found for Path= : Oxid=0x. Probable Cause Indicates that a Device Level Exception frame was received from the FICON channel.
FICN-1013 38 FICN-1013 Message , [FICN-1013], ,, INFO, , DevDiskIng:Status=0x received in odd state=0x from Path=0x sent LBY. Probable Cause Indicates that when the device sent the status in an incorrect state, the emulation processing rejected the status with an LBY frame.
38 FICN-1016 FICN-1016 Message , [FICN-1016], ,, INFO, , DevIng:Received Logical Path Removed response:Path=0x . Probable Cause Indicates the FICON Control Unit sent an LPR frame to the FICON channel. Recommended Action No action is required.
FICN-1020 Recommended Action Severity 38 If there was a job failure associated with this event, contact your switch service provider.
38 FICN-1023 FICN-1023 Message , [FICN-1023], ,, ERROR, , DevTapeEgr:FICON Selective Reset:Path= Elapsed Time=. seconds. Probable Cause Indicates that the FICON channel issued a Selective Reset sequence for a device.
FICN-1027 Recommended Action Severity 38 If there was an unexpected job failure or IO Error associated with this event, contact your switch service provider. INFO FICN-1027 Message , [FICN-1027], ,, ERROR, , DevTapeIng:Device level exception found for Path=: Oxid=0x.
38 FICN-1030 FICN-1030 Message , [FICN-1030], ,, ERROR, , HostDiskIng:FICON Purge received:Path= . Probable Cause Indicates an active disk emulation device received a FICON Purge Path from the channel. Recommended Action If there was an unexpected job failure or IO Error associated with this event, contact your switch service provider.
FICN-1034 Recommended Action Severity 38 No action is required. This is part of the FICON path initialization. INFO FICN-1034 Message , [FICN-1034], ,, ERROR, , HostEgr:Discarding Invalid LRCd Frame on Path= count=.
38 FICN-1037 FICN-1037 Message , [FICN-1037], ,, INFO, , HostIng:FICON ELP Request on Path= . Probable Cause Indicates that a locally connected FICON Channel issued an Establish Logical Path sequence to the specified FICON Control Unit. Recommended Action No action is required. This is a part of the FICON path activation.
FICN-1040 38 FICN-1040 Message , [FICN-1040], ,, ERROR, , HostTapeEgr:Tape:CmdReject Sense Data Rcvd:Path= LastCmds=0x SenseData:Bytes0-0xB=0x .
38 FICN-1043 FICN-1043 Message , [FICN-1043], ,, ERROR, , HostTapeIng::FICON Selective Reset:Path= state=0x LastCmds=0x LastStatus=0x.
FICN-1046 38 FICN-1046 Message , [FICN-1046], ,, WARNING, , HostTapeIng:LRJ received on Path= lastCmds=0x lastStatus=0x treating as system reset event.
38 FICN-1049 FICN-1049 Message , [FICN-1049], ,, WARNING, , ProcessIngTirData:Lost Logical Path for Path= Index=. Probable Cause Indicates a TIR received from a FICON end point indicates that it no longer has an established path to its peer.
FICN-1052 38 FICN-1052 Message , [FICN-1052], ,, INFO, , XRC Session Terminated: SessID=, Path=0x . Probable Cause Indicates a PSF command has been received to break an XRC session with the extended DASD device. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1056 Recommended Action Severity If this was an unexpected event, contact your vendor's customer support for assistance.
FICN-1059 38 FICN-1059 Message , [FICN-1059], ,, ERROR, , Error return from frame generation for a FICON Image: Path=0x . Probable Cause Indicates an internal resource shortage caused an error such that an emulation frame could not be created and sent to an LPAR. Recommended Action This is an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1062 FICN-1062 Message , [FICN-1062], ,, ERROR, , Ingress Abort:Oxid=0x:Path=0x :LastStates=0x . Probable Cause Indicates an abort operation has been received from the local FC interface for an active emulation exchange.
FICN-1065 38 FICN-1065 Message , [FICN-1065], ,, INFO, , Egress Abort:Oxid=0x:Unknown Path on GEPort= VEPort= from SID=0x
38 FICN-1069 Recommended Action Severity If there were associated IO errors at the same time as this event, contact your vendor's customer support for assistance. ERROR FICN-1069 Message , [FICN-1069], ,, ERROR, , Emulation Configuration Error on TunnelId . Probable Cause Indicates an error has been noted in the FICON configuration. Refer to the string for the nature of the configuration issue.
FICN-1072 38 FICN-1072 Message , [FICN-1072], ,, INFO, , DevTapeEgr:Tape Loaded on Path=0x . Probable Cause Indicates the tape IOs are processed from a locally connected LPAR, which indicates that a tape is loaded on a device. Recommended Action No action is required.
38 FICN-1075 FICN-1075 Message , [FICN-1075], ,, INFO, , HostTapeIngr:ReadBlkReport:Path= :Emuls=0x:Cmds=0x:Chains=0x:MBytes=
FICN-1078 Recommended Action Severity 38 No action is required.
38 FICN-1080 FICN-1080 Message , [FICN-1080], ,, INFO, , DevTapeEgr:ReadCpReport:Path=0x :Emuls=0x:Cmds=0x:Chains=0x:MBytes=
FICN-1083 38 FICN-1083 Message , [FICN-1083], ,, WARNING, , EmulEls:SW_RSCN received on GEPort= VEPort= Domain=0x Port=0x. Probable Cause Indicates an attached port with the established FICON emulated path has logged out from the switch. Recommended Action This may be an unexpected event, contact your vendor's customer support for assistance.
38 FICN-1087 FICN-1087 Message , [FICN-1087], ,, ERROR, , DevTeraEgr:AS Link Level Reject (LRJ) from Chan on Path=0x LastCmd=0x LastStatus=0x. Probable Cause Indicates the FICON channel indicated in the path issued an LRJ frame for a sequence from the device.
FICN-1090 38 FICN-1090 Message , [FICN-1090], ,, ERROR, , DevTeraEgr:FICON Selective Reset:Path=0x State=0x statArray=0x cmdArray=0x tflags=0x sflags=0x
38 FICN-1093 FICN-1093 Message , [FICN-1093], ,, WARNING, , DevTeraEgr:Auto Sense Data received on Path=0x Bytes0-0xB=0x. Probable Cause Indicates the FICON tera write pipeline processed sense data from a FICON device.
FICN-1096 38 FICN-1096 Message , [FICN-1096], ,, ERROR, , HostTeraEgr:CmdReject Sense Data Rcvd: Path=0x LastCmds=0x SenseData:Bytes0-0xB=0x.
38 FICN-1099 FICN-1099 Message , [FICN-1099], ,, ERROR, , HostTeraIng::FICON Selective Reset:Path=0x state=0x LastCmds=0x LastStatus=0x.
FICN-1102 38 FICN-1102 Message , [FICN-1102], ,, WARNING, , HostTeraIng:LRJ received on Path=0x lastCmds=0x lastStatus=0x treating as system reset event.
38 FICN-1105 FICN-1105 Message , [FICN-1105], ,, WARNING, , DevTeraIng:LRJ received on Path=0x lastCmds=0x lastStatus=0x treating as system reset event.
FICN-1108 38 FICN-1108 Message , [FICN-1108], ,, WARNING, , DevPrintEgr:FICON Tera Cancel:Path=0x Elapsed Time=. seconds. Probable Cause Indicates the FICON channel issued a Cancel sequence for a device in emulation.
38 FICN-1111 FICN-1111 Message , [FICN-1111], ,, ERROR, , DevPrintEgr:FICON Purge received Path=0x. Probable Cause Indicates the FICON channel issued a Purge Path command sequence for a device. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance.
FICN-1114 38 FICN-1114 Message , [FICN-1114], ,, ERROR, , DevPrintIng:Device level exception found for Path=0x: Oxid=0x. Probable Cause Indicates an active emulation device delivered a Device Level Exception frame to the emulation processing.
38 FICN-1117 FICN-1117 Message , [FICN-1117], ,, WARNING, , HostPrintIng:FICON Cancel received Path=0x state=0x. Probable Cause Indicates a job was cancelled during Print write pipelining. Recommended Action If this was an unexpected event (cancel is normally an operator event), contact your vendor's customer support for assistance.
FICN-1120 38 FICN-1120 Message , [FICN-1120], ,, WARNING, , HostPrintIng:FICON Purge received:Path=0x. Probable Cause Indicates a purge path was received from the locally connected FICON channel. This is performed during FICON path recovery. Recommended Action If this was an unexpected event, contact your vendor's customer support for assistance.
38 FICN-2005 FICN-2005 Message , [FICN-2005], ,, INFO, , FICON VEPort Feature Change verified Xrc <1 or 0 - XRC Emulation Enabled or Disabled> TapeWrt <1 or 0 - Tape Write Emulation Enabled or Disabled> TapeRd <1 or 0 - FICON Tape Read Emulation Enabled or Disabled> TinTir <1 or 0 - FICON TIN/TIR Emulation Enabled or Disabled> DvcAck <1 or 0 - FICON Device Level Ack Emulation Enabled or Disabled> RdBlkId <1 or 0 - FICON Write Emulation Read Block
FICN-2065 38 FICN-2065 Message , [FICN-2065], ,, INFO, , Egress Abort:Oxid=0x:Unknown Path on VEPort= from SID=0x to DID=0x. Probable Cause Indicates an abort operation has been received from a peer FC interface for an exchange.
38 FICN-2085 Recommended Action Severity This may be an unexpected event, contact your vendor's customer support for assistance. WARNING FICN-2085 Message , [FICN-2085], ,, INFO, , FICON or FCP Emulation Enabled FCIP Tunnel is Up on VEPort=. Probable Cause Indicates a FICON or FCP Emulation Enabled FCIP tunnel has been established successfully to the peer switch. Recommended Action No action is required.
Chapter FICU System Messages 39 FICU-1001 Message , [FICU-1001], ,, ERROR, , : config failed rc = . Probable Cause Indicates that one of the configuration management functions have failed. The key variable is a part of the Fabric OS configuration database and is for support use only. The error variable is an internal error number.
39 FICU-1004 FICU-1004 Message Probable Cause , [FICU-1004], ,, WARNING, , : Failed to set fabric manager server (FMS) mode: conflicting PID Format:, FMS Mode:. Indicates that a process ID (PID) format conflict was encountered. The core PID format is required for FICON-CUP.
FICU-1007 39 FICU-1007 Message , [FICU-1007], ,, WARNING, , : Failed to allocate memory while performing . Probable Cause Indicates that memory resources are low. This may be a transient problem. Recommended Action Check the memory usage in the switch using the memShow command.
39 FICU-1011 Recommended Action Severity Execute the portDisable command to disable ports with 0xFE or 0xFF areas. WARNING FICU-1011 Message , [FICU-1011], ,, INFO, , FMS mode has been enabled. Probable Cause Indicates that FMS mode has been enabled. Recommended Action No action is required. Severity INFO FICU-1012 Message , [FICU-1012], ,, INFO, , FMS mode has been disabled.
FICU-1018 Recommended Action Severity 39 Execute the wwnaddress --show command to display all the devices currently bound to areas. Execute wwnaddress --unbind [WWN] command to release the reserved area from the device. WARNING FICU-1018 Message , [FICU-1018], ,, WARNING, , FMSMODE enable noticed swapped ports. Probable Cause Indicates that some ports were swapped at the time of FMS mode enable.
39 FICU-1022 Recommended Action Severity No action is required. INFO FICU-1022 Message , [FICU-1022], ,, ERROR, , Detected FC8-48 and/or FC8-64 that are not manageable when FMS mode is enabled. Probable Cause Indicates presence of unmanageable ports (such as 48-port blade) in a Virtual Fabric disabled chassis. Recommended Action No action is required.
Chapter FKLB System Messages 40 FKLB-1001 Message , [FKLB-1001], ,, WARNING, , exchange overlapped, pid= Probable Cause Indicates that the FC kernel driver has timed out the exchange while the application is still active. When the FC kernel driver reuses the exchange, the application will overlap. This happens on a timed-out exchange; it automatically recovers after the application times the exchange out. Recommended Action No action is required.
40 328 FKLB-1001 Fabric OS Message Reference 53-1002448-01
Chapter FLOD System Messages 41 FLOD-1001 Message , [FLOD-1001], ,, WARNING, , Unknown LSR type: port , type Probable Cause Indicates that the link state record (LSR) type is unknown. The following two LSR header types are the only known types: 1 - Unicast and 3 - Multicast. Recommended Action No action is required because the record is discarded.
41 FLOD-1005 FLOD-1005 Message , [FLOD-1005], ,, WARNING, , Invalid received domain ID: . Probable Cause Indicates that the received LSR contained an invalid domain number. Recommended Action No action is required because the LSR is discarded. Severity WARNING FLOD-1006 Message , [FLOD-1006], ,, WARNING, , Transmitting invalid domain ID: .
Chapter FSPF System Messages 42 FSPF-1001 Message , [FSPF-1001], ,, ERROR, , Input Port out of range Probable Cause Indicates that the specified input port number is out of range as it does not exist on the switch. Recommended Action No action is required.
42 FSPF-1005 FSPF-1005 Message , [FSPF-1005], ,, ERROR, , Wrong Section Id , should be , input port = Probable Cause Indicates that an incorrect section ID was reported from the specified input port. The section ID is used to identify a set of switches that share an identical topology database. The section ID is implemented inside the protocol. The error message itself will indicate the mismatched section ID.
FSPF-1009 Recommended Action Severity 42 No action is required. INFO FSPF-1009 Message , [FSPF-1009], ,, ERROR, , ICL topology is invalid on local domain . Probable Cause Indicates that there is a problem with the current ICL configuration. The ICL connectivity of one or more neighbor domains violates the requirement of symmetric ICL connections on both core blades.
42 334 FSPF-1010 Fabric OS Message Reference 53-1002448-01
Chapter FSS System Messages 43 FSS-1001 Message , [FSS-1001], ,, WARNING, , Component () dropping HA data update (). Probable Cause Indicates that an application has dropped a High Availability (HA) data update. Recommended Action For dual Control Processor (CP) system, enable the HA state synchronization using the haSyncStart command. For nonbladed systems, restart the switch using the reBoot command.
43 FSS-1004 If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. Severity WARNING FSS-1004 Message , [FSS-1004], ,, ERROR, , Memory shortage. Probable Cause Indicates that the system ran out of memory. Recommended Action Execute the memShow command to view memory usage in the switch.
FSS-1007 43 FSS-1007 Message , [FSS-1007], ,, CRITICAL, , : Faulty Ethernet connection. Probable Cause Indicates that the Ethernet connection between the active CP and standby CP is not healthy. This error occurs when the standby CP does not respond to a request from the active CP within five seconds. This usually indicates a problem with the internal Ethernet connection and the disruption of the synchronization process.
43 FSS-1011 Recommended Action Severity Execute the supportSave command and contact your switch service provider. WARNING FSS-1011 Message , [FSS-1011], ,, INFO, , FSS Info: . Probable Cause Indicates an FSS-related informational message. Recommended Action No action is required.
Chapter FSSM System Messages 44 FSSM-1002 Message , [FSSM-1002], , SLOT cp-slot-number | CHASSIS, INFO, , HA State is in sync. Probable Cause Indicates that the High Availability (HA) state of the active Control Processor (CP) is in synchronization with the HA state of the standby CP. If the standby CP is healthy, the failover will be nondisruptive. Recommended Action No action is required.
44 FSSM-1004 In a switch system, this message is logged when a firmware upgrade or downgrade was invoked. The new firmware version is not compatiable with the current running version. This causes a disruptive firmware upgrade or downgrade. Recommended Action Severity 340 For a dual CP system, execute the firmwareDownload command to load compatible firmware on the standby CP.
Chapter FW System Messages 45 FW-1001 Message , [FW-1001], ,, INFO, ,
45 FW-1004 Recommended Action Severity This message generally appears when a fan fails. If so, a fan failure message accompanies this message. Replace the fan field-replaceable unit (FRU). WARNING FW-1004 Message , [FW-1004], ,, INFO, ,
FW-1011 45 FW-1011 Message , [FW-1011], ,, INFO, ,
45 FW-1035 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. WARNING FW-1035 Message , [FW-1035], ,, WARNING, ,
FW-1038 45 FW-1038 Message , [FW-1038], ,, WARNING, ,
45 FW-1041 FW-1041 Message , [FW-1041], ,, INFO, ,
FW-1044 45 FW-1044 Message , [FW-1044], ,, INFO, ,
45 FW-1047 FW-1047 Message , [FW-1047], ,, WARNING, ,
FW-1051 Recommended Action Severity 45 Configure the low threshold to 1 so that the threshold triggers an alarm when the value falls to 0 (Out_of_Range). If continuous or repeated alarms occur, replace the SFP before it deteriorates. WARNING FW-1051 Message , [FW-1051], ,, WARNING, ,
45 FW-1054 FW-1054 Message , [FW-1054], ,, WARNING, ,
FW-1115 45 FW-1115 Message , [FW-1115], ,, INFO, ,
45 FW-1118 FW-1118 Message Probable Cause , [FW-1118], ,, INFO, ,
FW-1121 • • • • Recommended Action Severity 45 Two switches with the same domain ID have connected to one another. Two fabrics have joined. An E_Port has gone offline. A principal link has segmented from the fabric. No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1121 Message , [FW-1121], ,, INFO, ,
45 FW-1124 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1124 Message , [FW-1124], ,, INFO, ,
FW-1127 45 • Domain conflicts. • Segmentation of the principal link between two switches. • Incompatible link parameters. During E_Port initialization, ports exchange link parameters. Rarely, incompatible parameters result in segmentation. A low number of segmentation errors means that the fabric is functioning normally. Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
45 FW-1129 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1129 Message , [FW-1129], ,, INFO, ,
FW-1132 45 FW-1132 Message , [FW-1132], ,, INFO, ,
45 FW-1135 FW-1135 Message , [FW-1135], ,, INFO, ,
FW-1138 45 FW-1138 Message , [FW-1138], ,, INFO, ,
45 FW-1160 FW-1160 Message , [FW-1160], ,, INFO, , ,
FW-1163 45 Losses of synchronization commonly cause link failures. If you receive concurrent loss of synchronization errors, troubleshoot the loss of synchronization. Severity WARNING FW-1163 Message , [FW-1163], ,, INFO, , ,
45 FW-1166 Recommended Action Severity No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1166 Message , [FW-1166], ,, WARNING, , ,
FW-1169 Recommended Action Severity 45 Check both ends of your cable connection. Verify that the cable and small form-factor pluggables (SFPs) are not faulty. INFO FW-1169 Message , [FW-1169], ,, INFO, , ,
45 FW-1172 FW-1172 Message , [FW-1172], ,, INFO, , ,
FW-1175 45 FW-1175 Message , [FW-1175], ,, INFO, , ,
45 FW-1178 FW-1178 Message , [FW-1178], ,, WARNING, , ,
FW-1181 45 FW-1181 Message , [FW-1181], ,, INFO, , ,
45 FW-1184 FW-1184 Message , [FW-1184], ,, INFO, , ,
FW-1188 Recommended Action Severity 45 No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation. INFO FW-1188 Message , [FW-1188], ,, INFO, , ,
45 FW-1191 FW-1191 Message , [FW-1191], ,, INFO, , ,
FW-1194 45 FW-1194 Message , [FW-1194], ,, WARNING, , ,
45 FW-1197 FW-1197 Message , [FW-1197], ,, INFO, , ,
FW-1200 45 FW-1200 Message , [FW-1200], ,, INFO, , ,
45 FW-1204 Recommended Action Severity Check the target device; it could be slow. INFO FW-1204 Message , [FW-1204], ,, INFO, , ,
FW-1207 45 FW-1207 Message , [FW-1207], ,, INFO, , ,
45 FW-1246 FW-1246 Message , [FW-1246], ,, INFO, ,
FW-1249 45 FW-1249 Message , [FW-1249], ,, INFO, ,
45 FW-1272 FW-1272 Message , [FW-1272], ,, INFO, ,
FW-1275 45 FW-1275 Message , [FW-1275], ,, INFO, ,
45 FW-1298 FW-1298 Message , [FW-1298], ,, WARNING, ,
FW-1301 45 FW-1301 Message , [FW-1301], ,, INFO, ,
45 FW-1308 FW-1308 Message , [FW-1308], ,, INFO, ,
FW-1334 45 FW-1334 Message , [FW-1334], ,, WARNING, ,
45 FW-1337 FW-1337 Message , [FW-1337], ,, INFO, ,
FW-1339 45 FW-1339 Message , [FW-1339], ,, INFO, ,
45 FW-1342 FW-1342 Message , [FW-1342], ,, WARNING, ,
FW-1350 45 FW-1350 Message , [FW-1350], ,, WARNING, ,
45 FW-1354 Recommended Action Severity No action is required. INFO FW-1354 Message , [FW-1354], ,, WARNING, ,
FW-1356 45 FW-1356 Message , [FW-1356], ,, INFO, ,
45 FW-1359 FW-1359 Message , [FW-1359], ,, INFO, ,
FW-1366 45 FW-1366 Message , [FW-1366], ,, WARNING, ,
45 FW-1369 FW-1369 Message , [FW-1369], ,, INFO, ,
FW-1372 Recommended Action Severity 45 No action is required. INFO FW-1372 Message , [FW-1372], ,, INFO, ,
45 FW-1375 Recommended Action Severity Responses to security-class messages depend on user policies. Consult your security administrator for response strategies and policies. WARNING FW-1375 Message , [FW-1375], ,, INFO, ,
FW-1377 45 FW-1377 Message , [FW-1377], ,, INFO, ,
45 FW-1400 Recommended Action Severity No action is required. INFO FW-1400 Message , [FW-1400], ,, INFO, ,
FW-1403 45 FW-1403 Message , [FW-1403], ,, INFO, ,
45 FW-1407 Recommended Action Severity No action is required. CRITICAL FW-1407 Message , [FW-1407], ,, INFO, ,
FW-1425 45 FW-1425 Message , [FW-1425], ,, INFO, , Switch status changed from to HEALTHY. Probable Cause Indicates that the switch status has changed to a healthy state. This occurred because a policy is no longer violated. Recommended Action No action is required. Respond to this message as is appropriate to the particular policy of the end-user installation.
45 FW-1429 Recommended Action Severity Replace the missing power supply. WARNING FW-1429 Message , [FW-1429], ,, WARNING, , Switch status change contributing factor: Power supplies are not redundant. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the power supplies are not in the correct slots for redundancy.
FW-1432 45 FW-1432 Message , [FW-1432], ,, WARNING, , Switch status change contributing factor WWN: bad. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the number of faulty World Wide Name (WWN) cards is greater than or equal to the policy set by the switchStatusPolicySet command. Recommended Action Replace the faulty WWN card.
45 FW-1435 FW-1435 Message , [FW-1435], ,, WARNING, , Switch status change contributing factor Flash: usage out of range. Probable Cause Indicates that the switch status is not in a healthy state. This occurred because the flash usage is out of range. The policy was set using the switchStatusPolicySet command. Recommended Action Execute the supportSave command to clear out the kernel flash.
FW-1438 45 FW-1438 Message , [FW-1438], ,, WARNING, , Switch status change contributing factor Missing SFPs: missing out of SFPs:config( percent,). (Port(s) ). Probable Cause Indicates that the switch status is not in a healthy state.
45 FW-1442 Recommended Action Severity Verify that the event was planned. INFO FW-1442 Message , [FW-1442], ,, INFO, , state has changed to . Probable Cause Indicates that the state of the specified field-replaceable unit (FRU) has changed to on. Recommended Action No action is required. Verify that the event was planned.
FW-1445 45 FW-1445 Message , [FW-1445], ,, INFO, , Four power supplies are now required for 2X redundancy, Switch Status Policy values changed. Probable Cause Indicates that the switch now requires four power supplies and previous Switch Status Policy parameters will be overwritten to reflect this. The presence of an AP blade means that more than one power supply may be required to provide adequate power.
45 FW-1448 FW-1448 Message , [FW-1448], ,, WARNING, , Switch status change contributing factor Error ports: Error out of ports:config( percent,). (Port(s) ). Probable Cause Indicates that the switch is not in a healthy state. This occurred because the number of faulty ports are greater than or equal to the policy set by the switchStatusPolicySet command.
FW-1510 Recommended Action Severity 45 Reconfigure a valid e-mail address. WARNING FW-1510 Message , [FW-1510], ,, WARNING, , threshold exceeded(High=). Current value is : Port disabled. Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple link failures that exceed Fabric Watch threshold on the port.
45 FW-1512 FW-1512 Message , [FW-1512], ,, INFO, , ,
FW-1515 45 FW-1515 Message , [FW-1515], ,, INFO, , ,
45 FW-1518 FW-1518 Message , [FW-1518], ,, INFO, , ,
FW-1521 45 FW-1521 Message , [FW-1521], ,, INFO, , ,
45 FW-1524 FW-1524 Message , [FW-1524], ,, INFO, , ,
FW-1527 45 FW-1527 Message , [FW-1527], ,, INFO, , ,
45 FW-1530 FW-1530 Message , [FW-1530], ,, INFO, , ,
FW-1533 45 FW-1533 Message , [FW-1533], ,, INFO, , ,
45 FW-3011 Recommended Action Severity Respond to this message as it is appropriate to the particular policy of the end-user installation. INFO FW-3011 Message , [FW-3011], ,, INFO, , ,
FW-3014 45 FW-3014 Message , [FW-3014], ,, INFO, , ,
45 FW-3018 Recommended Action Severity No action is required. INFO FW-3018 Message , [FW-3018], ,, INFO, , ,
FW-3021 45 FW-3021 Message , [FW-3021], ,, WARNING, , ,
45 420 FW-3022 Fabric OS Message Reference 53-1002448-01
Chapter HAM System Messages 46 HAM-1001 Message Probable Cause , [HAM-1001], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, , Standby CP is not healthy, device status BAD, Severity = . Indicates that a standby control processor (CP) device error is reported by the High Availability Manager (HAM) Health Monitor, with the specified device and Log="YES” Class=”NONE" Severity level.
46 HAM-1005 • • • • • • • • • • • • • • • • • Recommended Action Severity Giveup Master:SYSM CP Faulty:SYSM FirmwareDownload ConfigDownload:MS ChangeWWN:EM Reboot:WebTool Fastboot:WebTool Software Fault:Software Watchdog Software Fault:Kernel Panic Software Fault:ASSERT Reboot:SNMP Fastboot:SNMP Reboot Chassis Config Reboot:API Reboot:HAM EMFault:EM Execute the errShow command on both the CPs to view the error log for additional messages that may indicate reason for the switch restart.
HAM-1007 Recommended Action Severity 46 The standby CP will take over and reset the active CP. The system will be non-redundant because the standby CP becomes the active CP. CRITICAL HAM-1007 Message , [HAM-1007], , SLOT cp-slpt-number | FFDC | CHASSIS, FFDC, CRITICAL, , Need to reboot the system for recovery, reason: . Probable Cause Indicates that the switch in current condition needs to be restarted to achieve a reliable recovery.
46 HAM-1010 Recommended Action Severity Execute the reboot command to restart the switch manually. CRITICAL HAM-1010 Message , [HAM-1010], , SLOT cp-slot-number | CHASSIS, CRITICAL, , Maunually trigger hareboot/reboot for recovery from OOM, when appropriate. Probable Cause Indicates that Out Of Memory (OOM) condition has been detected when the switch was not ready for warm recovery.
HAM-1013 46 HAM-1013 Message , [HAM-1013], , SLOT cp-slot-number | CHASSIS, CRITICAL, , . Probable Cause Indicates that the software watchdog detected termination of a restartable daemon, but could not restart the daemon. Recommended Action Manually initiate a restart or failover, if needed. Severity CRITICAL HAM-1014 Message , [HAM-1014], , SLOT cp-slot-number | CHASSIS, CRITICAL, , .
46 426 HAM-1014 Fabric OS Message Reference 53-1002448-01
Chapter HAMK System Messages 47 HAMK-1001 Message , [HAMK-1001], , SLOT cp-slot-number | CHASSIS, FFDC, CRITICAL, , Warm recovery failed. Probable Cause Indicates that the switch failed during the warm recovery. Recommended Action This event triggers a switch restart automatically and attempts a cold recovery.
47 HAMK-1004 HAMK-1004 Message ,[HAMK-1004], , SLOT cp-slot-number | CHASSIS, INFO, , Resetting standby CP (double reset may occur). Probable Cause Indicates that the standby CP is being reset due to a loss of heartbeat. Typically, this message is displayed when the standby CP has been restarted. Note that in certain circumstances a CP may experience a double reset and restart twice in a row. A CP can recover automatically even if it has restarted twice.
Chapter HIL System Messages 48 HIL-1101 Message , [HIL-1101], ,, ERROR, , Slot faulted, () is above threshold. Probable Cause Indicates that the blade voltage is above threshold. Recommended Action Replace the faulty blade or switch (for nonbladed switches).
48 HIL-1104 HIL-1104 Message , [HIL-1104], ,, ERROR, , Blower faulted, () is below threshold. Probable Cause Indicates that the fan voltage is below threshold. Recommended Action Run the psShow command to verify the power supply status. Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they are seated properly.
HIL-1107 48 HIL-1107 Message , [HIL-1107], , FFDC, CRITICAL, , Switch faulted, ()above threshold. System preparing for reset. Probable Cause Indicates that the switch voltage is above threshold. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
48 HIL-1202 If the fan continues to generate this message, replace the fan FRU. Severity WARNING HIL-1202 Message , [HIL-1202], ,, ERROR, , Blower faulted, speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. Recommended Action Replace the fan FRU.
HIL-1206 48 HIL-1206 Message , [HIL-1206], ,, ERROR, , Fan sensor , speed ( RPM) below threshold. Probable Cause Indicates that the specified fan speed (in RPMs) has fallen below the minimum threshold. This problem can quickly cause the switch to overheat. This message is specific to nonbladed switches and is not applicable to the Brocade 24000 or 48000.
48 HIL-1301 HIL-1301 Message , [HIL-1301], ,, WARNING, , 1 blower failed or missing. Replace failed or missing blower assembly immediately. Probable Cause Indicates that a fan field-replaceable unit (FRU) has failed or has been removed. This message is often preceded by a low speed error message. This problem can cause the switch to overheat. Recommended Action Replace the affected fan FRU immediately.
HIL-1305 Recommended Action Severity 48 Replace the faulty fan FRUs immediately. ERROR HIL-1305 Message , [HIL-1305], ,, ERROR, , One or two fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that multiple fan field-replaceable units (FRUs) have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan FRUs immediately.
48 HIL-1308 HIL-1308 Message , [HIL-1308], ,, ERROR, , All fans failed. Replace failed fan FRUs immediately. Probable Cause Indicates that all fans have failed. This message is often preceded by a low fan speed message. Recommended Action Replace the faulty fan field-replaceable units (FRUs) immediately. Severity ERROR HIL-1309 Message , [HIL-1309], ,, ERROR, , fan FRUs failed.
HIL-1401 48 If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty behavior. Replace the switch because the fan is not field-replaceable. Severity INFO HIL-1401 Message , [HIL-1401], ,, WARNING, , One fan FRU missing. Install fan FRU immediately. Probable Cause Indicates that one fan field-replaceable unit (FRU) has been removed. Recommended Action Install the missing fan FRU.
48 HIL-1501 Recommended Action Severity Install the missing fan FRUs immediately. WARNING HIL-1501 Message , [HIL-1501], ,, WARNING, , Slot , high temperature (). Probable Cause Indicates that the temperature of this blade has risen above the warning threshold. Recommended Action Run the fanShow command to verify all the fans are working properly.
HIL-1504 48 Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. If the message persists, replace the faulty blade. Severity CRITICAL HIL-1504 Message , [HIL-1504], ,, INFO, , System within normal temperature specifications ( C).
48 HIL-1507 Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL-1507 Message , [HIL-1507], , FFDC, CRITICAL, , High temperature warning time expired. System preparing for shutdown. Probable Cause Indicates that temperatures in the system have risen above the critical threshold.
HIL-1510 48 Make sure that the area is well-ventilated and that the room temperature is within operational range of your switch. Refer to the hardware reference manual for your switch for the operational temperature range. Severity CRITICAL HIL-1510 Message , [HIL-1510], ,, WARNING, , Current temperature ( C) is below shutdown threshold. System shutdown cancelled.
48 HIL-1603 HIL-1603 Message , [HIL-1603], , FFDC, CRITICAL, , fans out of service. System is shutting down immediately. Probable Cause Indicates that the total fan failure count is greater than or equal to two. Recommended Action To avoid causing damage to the switch, the system shuts down automatically. To help prevent future problems, make sure that all the fans are working properly.
HIL-1612 Recommended Action Severity 48 Ensure fan units have same direction. Check fan directions with chassisshow command. CRITICAL HIL-1612 Message , [HIL-1612], ,, CRITICAL, , MISMATCH in PSU-FAN Air Flow direction.System shut down. Probable Cause Indicates that PSU FAN Air Flows are in reverse direction. System will be shut down. Applicable only to Brocade 6510. Recommended Action Ensure fan units have same direction.
48 444 HIL-1650 Fabric OS Message Reference 53-1002448-01
Chapter HLO System Messages 49 HLO-1001 Message , [HLO-1001], , FFDC, ERROR, , Incompatible Inactivity timeout from port , correct value . Probable Cause Indicates that the HLO message was incompatible with the value specified in the FSPF protocol. The Brocade switch will not accept FSPF frames from the remote switch.
49 HLO-1003 The switch has received an invalid HLO because either the domain or port number in the HLO message has an invalid value. This error can only occur when the Brocade switch is connected to a switch from another manufacturer. Recommended Action Severity 446 The HLO message of the remote switch must be compatible with the value specified in the FSPF protocol. Refer to the documentation for the other manufacturer's switch to change this value.
Chapter HMON System Messages 50 HMON-1001 Message , [HMON-1001], , FFDC, CRITICAL, , Probable Cause Indicates there was a problem reading an essential file containing configuration information from the nonvolatile storage device. This could be the result of a missing file or a corrupt file system. Recommended Action Run the firmwareDownload command to reinstall the firmware to your switch.
50 448 HMON-1001 Fabric OS Message Reference 53-1002448-01
Chapter HSL System Messages 51 HSL-1000 Message , [HSL-1000], ,, CRITICAL, , HSL initialization failed. Probable Cause Indicates an HSL initialization failure. Recommended Action No action is required. Severity CRITICAL HSL-1001 Message , [HSL-1001], ,, CRITICAL, , Failed to acquire system mac address pool. Probable Cause Indicates the failure to acquire a system address.
51 HSL-1004 Recommended Action Severity No action is required. INFO HSL-1004 Message , [HSL-1004], ,, ERROR, , Incompatible SFP for interface is detected. Probable Cause Indicates an incompatible SFP for the interface has been inserted. Recommended Action Use the correct SFP for this interface. Severity ERROR HSL-1005 Message , [HSL-1005], ,, CRITICAL, , Failed to initialize with FSS.
HSL-1007 Recommended Action Severity 51 No action is required.
51 452 HSL-1007 Fabric OS Message Reference 53-1002448-01
Chapter HTTP System Messages 52 HTTP-1001 Message , [HTTP-1001], ,, INFO, , Switch PIDformat has changed to . Probable Cause Indicates that the PID format was changed by the administrator. Recommended Action No action is required. For more information on PID format, refer to the Fabric OS Administrator’s Guide.
52 454 HTTP-1003 Fabric OS Message Reference 53-1002448-01
Chapter IBD System Messages 53 IBD-1000 Message , [IBD-1000], ,, ERROR, , Slot , Port GE: Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power off and power on the blade using the slotPowerOff and slotPowerOn commands.
53 456 IBD-1000 Fabric OS Message Reference 53-1002448-01
Chapter IBPD System Messages 54 IBPD-1001 Message , [IBPD-1001], ,, WARNING, , : initiator name length exceeds the character limit [] Probable Cause Indicates that the initiator name length exceeds the supported limit of characters. Recommended Action Change the initiator name, keeping the number of characters within the supported limit.
54 458 IBPD-1003 Fabric OS Message Reference 53-1002448-01
Chapter ICPD System Messages 55 ICPD-1001 Message , [ICPD-1001], ,, ERROR, , Failed to allocate memory: (). Probable Cause Indicates that the specified function failed to allocate memory. Recommended Action Check memory usage on the switch using the memShow command. Severity Reboot or power cycle the switch.
55 ICPD-1005 Recommended Action Severity Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer to the Fabric OS Command Reference for more information on this command. WARNING ICPD-1005 Message , [ICPD-1005], ,, WARNING, , iSCSI configuration between local switch () and peer () is out of sync. iSCSI login is not allowed.
ICPD-1008 Recommended Action Severity 55 No action is required.
55 462 ICPD-1008 Fabric OS Message Reference 53-1002448-01
Chapter IPAD System Messages 56 IPAD-1000 Message , [IPAD-1000], ,, INFO, , . Probable Cause Indicates that the local IP address has been changed.
56 IPAD-1003 Recommended Action Severity No action is required. INFO IPAD-1003 Message , [IPAD-1003], ,, INFO, , DNS parameters saved successfully. Probable Cause Indicates that the Domain Name System (DNS) parameters are saved successfully. Recommended Action No action is required. Severity INFO IPAD-1004 Message , [IPAD-1004], ,, INFO, , DNS parameters removed successfully.
Chapter IPS System Messages 57 IPS-1001 Message , [IPS-1001], ,, WARNING, , FCIP License Not Installed () Probable Cause Indicates that the FCIP license is not installed on the switch. Recommended Action Run the licenseShow command to check the installed licenses on the switch. Contact your switch supplier for a FCIP license. Run the licenseAdd command to add the license to your switch.
57 IPS-1004 IPS-1004 Message , [IPS-1004], ,, WARNING, , Port Config Mode Mismatch slot () port(ge): current mode is () Probable Cause Indicates that configured Port Mode is different from the intended use. Recommended Action Change the port configuration (by deleting configured FCIP tunnels or iSCSI sessions) to return the port mode to neutral before attempting to configure the port for a different mode or use.
IPS-1007 Recommended Action Severity 57 Change the tunnel configuration to remove IPSec configurations or insert a GA2 revised FX8-24 blade.
57 468 IPS-1007 Fabric OS Message Reference 53-1002448-01
Chapter ISNS System Messages 58 ISNS-1001 Message , [ISNS-1001], ,, INFO, , Configuration peering with external iSNS server slot/port /ge (current /ge). Probable Cause Indicates that the user has issued the isnscCfg command. Recommended Action No action is required.
58 ISNS-1004 ISNS-1004 Message , [ISNS-1004], ,, WARNING, , Timeout refreshing iSNS database with iSNS server slot/port /ge Reg-Period . Probable Cause Indicates that the internet storage name service (iSNS) client failed to receive a successful response for a DevAttrQry within the specified Registration-Period.
ISNS-1009 Recommended Action Severity 58 No action is required. You may change the configuration and retry the peering with the external iSNS server. INFO ISNS-1009 Message , [ISNS-1009], ,, INFO, , Peering with external iSNS server not started because no virtual targets found. Probable Cause Indicates that no virtual targets were found, so peering was not started. Recommended Action No action is required.
58 ISNS-1013 ISNS-1013 Message , [ISNS-1013], ,, WARNING, , iSNS server connection failure. Probable Cause Indicates that the internet storage name service (iSNS) client failed to establish a connection with the iSNS server. Recommended Action Verify the connection of the iSNS server to the slot or port. Use the isnscCfg command to display or correct the server IP address.
Chapter KAC System Messages 59 KAC-1002 Message , [KAC-1002], ,, ERROR, , KAC() communication Error: Error connecting to . Probable Cause Indicates that the key archival client is unable to communicate with the primary or backup key vault. Recommended Action Determine whether the configured key vault is operational, and if it is not, change the switch key vault settings or resolve the operational problem at the vault.
59 KAC-1007 KAC-1007 Message , [KAC-1007], ,, WARNING, , KAC put key to key vault failed, LUN=, keyID=, errno=. Probable Cause Indicates that the key archival client is unable to put to the primary or backup key vault. Recommended Action Determine whether the configured key value is operational, and if it is not, change the switch key vault settings or resolve the operational problem at the vault.
KAC-1011 59 KAC-1011 Message , [KAC-1011], ,, WARNING, , Putting the dummy DEK to the KV failed. Dummy DEK: , KeyCount: . Error code=, string=. Probable Cause Indicates that putting the Dummy failed to keyvault. Recommended Action No action is required.
59 KAC-1015 Recommended Action Severity No action is required. WARNING KAC-1015 Message , [KAC-1015], ,, ERROR, , KAC() communication Error: Error connecting to . Error code=, string=. Probable Cause Indicates that key archival client is unable to communicate with the primary or backup key vault.
Chapter KSWD System Messages 60 KSWD-1001 Message , [KSWD-1001], , FFDC, WARNING, , : failed to refresh (:). Probable Cause Indicates that one of the critical daemons is found to be nonresponsive. An abort signal is sent. Recommended Action Copy the warning message along with any core file information, and contact your switch service provider.
60 478 KSWD-1002 Fabric OS Message Reference 53-1002448-01
Chapter KTRC System Messages 61 KTRC-1001 Message , [KTRC-1001], ,, WARNING, , Dump memory size exceeds dump file size Probable Cause Indicates the dump memory size has exceeded the dump file size. Recommended Action No action is required. Severity WARNING KTRC-1002 Message , [KTRC-1002], ,, INFO, , Concurrent trace dumping. Probable Cause Indicates the initial background dump has not completed.
61 KTRC-1005 Recommended Action Severity No action is required. ERROR KTRC-1005 Message , [KTRC-1005], ,, ERROR, , Trace initialization failed. . . Probable Cause Indicates that a trace was unable to initialize. Recommended Action No action is required.
Chapter L2SYS System Messages 62 L2SS-1001 Message , [L2SS-1001], ,, ERROR, , Linux socket error - error reason: , socket name: , error name: . Probable Cause Indicates that an error has occurred in the Linux socket. Recommended Action Restart the Layer 2 system daemon (l2sysd). Severity ERROR L2SS-1002 Message , [L2SS-1002], ,, ERROR, , Initialization error: .
62 L2SS-1004 L2SS-1004 Message , [L2SS-1004], ,, ERROR, , FDB error: Error in creating AVL tree. Probable Cause Indicates that the l2sys has encountered an error while initializing the AVL tree. Recommended Action Restart the l2sys daemon. Severity ERROR L2SS-1005 Message , [L2SS-1005], ,, ERROR, , Mac-address-table hash failed even after two attempts for slot chip .
L2SS-1008 62 L2SS-1008 Message , [L2SS-1008], ,, INFO, , Hardware gid limit reached on chip , gid limit at . Probable Cause Indicates that all the dynamic Group IDs (GIDs) are allocated. Recommended Action Clear some of the ACL entries using the clear counters access-list mac command.
62 484 L2SS-1008 Fabric OS Message Reference 53-1002448-01
Chapter L3SS System Messages 63 L3SS-1004 Message , [L3SS-1004], ,, ERROR, , , : HW/Driver Error (possibly the CAM is full): , rc=. Probable Cause Indicates an error in the hardware or the driver of the Layer 3 subsystem (L3SS). The L3SS may have passed invalid parameters or the hardware content-addressable memory (CAM) may be full. Recommended Action Retry or clear the CAM.
63 486 L3SS-1004 Fabric OS Message Reference 53-1002448-01
Chapter LACP System Messages 64 LACP-1001 Message , [LACP-1001], ,, ERROR, , Error opening socket (). Probable Cause Indicates that initialization of the specified module within the Link Aggregation Control Protocol (LACP) daemon has failed. Recommended Action Download a new firmware using the firmwareDownload command. Severity ERROR LACP-1002 Message , [LACP-1002], ,, ERROR, , .
64 488 LACP-1002 Fabric OS Message Reference 53-1002448-01
Chapter LANCE System Messages 65 LANCE-1000 Message , [LANCE-1000], ,, ERROR, , Slot Port GE : Maximum attempts to restart failed. Disabling port. Probable Cause Indicates that the specified port has crashed unexpectedly and restarting attempts have failed. Recommended Action Power off and power on the blade using the slotPowerOff and slotPowerOn commands.
65 490 LANCE-1000 Fabric OS Message Reference 53-1002448-01
Chapter LFM System Messages 66 LFM-1001 Message , [LFM-1001], ,, INFO, , The Logical Fabric Manager service is disabled. Probable Cause Indicates that the Logical Fabric Manager service is disabled. Note that the Logical Fabric Manager service is enabled by the factory setting and it is not user configurable. Recommended Action No action is required.
66 LFM-1004 LFM-1004 Message , [LFM-1004], , FFDC, CRITICAL, , HA is out of sync for opcode , error value . Probable Cause Indicates the trigger for some internal logging purpose. Recommended Action Send the ffdc log to the support. Severity CRITICAL LFM-1005 Message , [LFM-1005], ,, WARNING, , Logical port disabled with reason ().
Chapter LOG System Messages 67 LOG-1000 Message , [LOG-1000], ,, INFO, , Previous message repeated times. Probable Cause Indicates the previous message repeated the specified number of times. Recommended Action No action is required. Severity INFO LOG-1001 Message , [LOG-1001], , FFDC, WARNING, , A log message was dropped. Probable Cause Indicates a log message was dropped.
67 LOG-1003 LOG-1003 Message , [LOG-1003], ,, INFO, , The log has been cleared. Probable Cause Indicates the persistent error log has been cleared. Recommended Action No action is required. Severity INFO LOG-1004 Message , [LOG-1004], ,, INFO, , Log message flooding detected and blocked. Probable Cause Indicates that a message has been flooding and has been blocked.
Chapter LSDB System Messages 68 LSDB-1001 Message , [LSDB-1001], ,, ERROR, , Link State ID out of range. Probable Cause Indicates the specified link state database ID is out of the acceptable range. The valid link state ID is the same as the valid domain ID, whose range is from 1 through 239. The switch will discard the record because it is not supported. Recommended Action No action is required.
68 LSDB-1004 Recommended Action Severity Run the switchDisable and switchEnable commands. A new local link state record is generated during the switch enable. CRITICAL LSDB-1004 Message , [LSDB-1004], ,, WARNING, , No Link State Record for domain . Probable Cause Indicates there is no link state record for the specified local domain. Recommended Action No action is required. The other switch will pass the LSD once the fabric is stable.
Chapter MCAST_SS System Messages 69 MCAST_SS-1001 Message , [MCAST_SS-1001], ,, ERROR, , Socket Error: () for socket the error code. Probable Cause Indicates error encountered in Linux socket. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1005 Recommended Action Severity Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1005 Message , [MCAST_SS-1005], ,, ERROR, , Message error: Invalid message type expecting or or . Probable Cause Indicates that type in the message recieved from driver is invalid. Recommended Action Try restarting the mcast_ssd daemon.
MCAST_SS-1009 Recommended Action Severity 69 Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1009 Message , [MCAST_SS-1009], ,, ERROR, , L2SS error : () vlan mac . Probable Cause Indicates that mcast_ss encountered L2SS related errors. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1013 Recommended Action Severity Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1013 Message , [MCAST_SS-1013], ,, ERROR, , Snooping DB error : () Group Not found - Vlan group . Probable Cause Indicates that the group address lookup for a VLAN failed. Recommended Action Try restarting the mcast_ssd daemon.
MCAST_SS-1017 Recommended Action Severity 69 Try restarting the mcast_ssd daemon. ERROR MCAST_SS-1017 Message , [MCAST_SS-1017], ,, ERROR, , Learning error: () Invalid number for ifindex . Probable Cause Indicates that mcast_ss encountered an error while learning MAC addresses. Recommended Action Try restarting the mcast_ssd daemon.
69 MCAST_SS-1020 Recommended Action Severity 502 Try restarting the mcast_ssd daemon.
Chapter MFIC System Messages 70 MFIC-1001 Message , [MFIC-1001], ,, ERROR, , Failure at sysmod_scn registry rc= . Probable Cause Indicates that the system is temporarily out of resources. Recommended Action This error is often transitory. Severity Execute the reBoot or haFailover commands (if applicable).
70 MFIC-1003 MFIC-1003 Message , [MFIC-1003], ,, WARNING, , Effective Insistent domain ID for the fabric changed from to . Probable Cause Indicates that one or more switches joined the fabric with an insistent domain ID (IDID) mode setting that is different from the current effective IDID mode for the fabric. This message also occurs when the IDID for the fabric has been turned on or off. The possible values for the state variable are On and Off.
Chapter MPTH System Messages 71 MPTH-1001 Message , [MPTH-1001], , FFDC, ERROR, , Null parent, lsId = . Probable Cause Indicates a null parent was reported. MPATH uses a tree structure in which the parent is used to connect to the root of the tree. Recommended Action No action is required. Severity ERROR MPTH-1002 Message , [MPTH-1002], , FFDC, ERROR, , Null lsrP, lsId = .
71 506 MPTH-1003 Fabric OS Message Reference 53-1002448-01
Chapter MQ System Messages 72 MQ-1004 Message Probable Cause , [MQ-1004], ,, ERROR, , mqRead, queue = , queue ID = , type = Indicates an unexpected message has been received in the specified message queue. The queue name is always fspf_q.
72 MQ-1006 MQ-1006 Message , [MQ-1006], ,, WARNING, , queue : msg too long (:) Probable Cause Indicates the incoming message size is larger than the message queue size. Recommended Action No action is required.
Chapter MS System Messages 73 MS-1001 Message , [MS-1001], ,, WARNING, , MS Platform Segmented port= (0x) ( (0x)) Probable Cause Indicates the management server (MS) has segmented from another switch domain at the specified port number because of errors or inconsistencies defined in the MS platform service. Recommended Action Restart or power cycle the switch.
73 MS-1003 • Run the firmwareDownload command to upgrade the firmware level on the switch to a level that supports RCS. RCS is supported in Fabric OS v2.6, v3.1 and greater, and v4.1 and greater. • Wait a few minutes and try the command again. Severity INFO MS-1003 Message Probable Cause , [MS-1003], ,, INFO, , MS detected Unstable Fabric().
MS-1005 73 If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity INFO MS-1005 Message , [MS-1005], ,, ERROR, , MS Invalid CT Response from d=. Probable Cause Indicates the management server (MS) received an invalid common transport (CT) response from the switch domain.
73 MS-1009 If the error persists, check the available memory on the switch using the memShow command. Severity ERROR MS-1009 Message Probable Cause , [MS-1009], ,, ERROR, , RLIR event. Switch Port ID is (). Device Port Tag is . . Indicates a registered link incident record (RLIR) has been generated for one of the actions indicated by the .
MS-1023 Recommended Action Severity 73 No action is required. INFO MS-1023 Message , [MS-1023], ,, INFO, , Management Server Topology Discovery Service . Probable Cause Indicates Management Server Topology Discovery Service is being enabled or disabled. Recommended Action No action is required.
73 MS-1026 MS-1026 Message , [MS-1026], ,, WARNING, , MS Platform disabled port domain to block enabling Platform service through merge operation. Probable Cause Indicates the management server (MS) has disabled E-port port number connected to domain because implicit enable operation of platform service is blocked. Recommended Action Enable Platform service on the switch and renable the port to join the fabric.
Chapter MSTP System Messages 74 MSTP-1001 Message , [MSTP-1001], ,, ERROR, , :. Probable Cause Indicates that the system has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Severity Restart or power cycle the switch. ERROR MSTP-1002 Message , [MSTP-1002], ,, ERROR, , :.
74 MSTP-2002 Recommended Action Severity No action is required INFO MSTP-2002 Message , [MSTP-2002], ,, INFO, , . My Bridge ID: Old Root: New Root: Probable Cause Indicates that the MSTP bridge or bridge instance root has changed. Recommended Action No action is required.
MSTP-2006 Recommended Action Severity 74 No action is required. INFO MSTP-2006 Message , [MSTP-2006], ,, INFO, , MSTP instance brigde priority is changed from to . Probable Cause Indicates that the MSTP instance priority has modified. Recommended Action No action is required.
74 518 MSTP-2006 Fabric OS Message Reference 53-1002448-01
Chapter NBFS System Messages 75 NBFS-1001 Message Probable Cause , [NBFS-1001], ,, INFO, , Duplicate E_Port SCN from port in state () Indicates a duplicate E_Port State Change Number was reported.
75 NBFS-1003 Recommended Action Severity Run the nbrStateShow command to check the neighbor state of the port listed in the message. If it is FULL, then this message can safely be ignored. Otherwise, run the portDisable and portEnable commands to refresh the port.
Chapter NS System Messages 76 NS-1001 Message , [NS-1001], ,, WARNING, , The response for request 0x from remote switch 0x is larger than the max frame size the remote switch can support! Probable Cause Indicates the response payload exceeds the maximum frame size the remote switch can handle. Recommended Action Run the firmwareDownload command to upgrade the remote switch with firmware v4.3 or higher, or v3.
76 NS-1004 Recommended Action To avoid disruption of traffic in the event of an unplanned failover, schedule a firmwareDownload so that the active and standby CPs have the same firmware version. Reduce the local device count to follow the capability of the lowest version of firmware.
NS-1007 76 NS-1007 Message , [NS-1007], ,, WARNING, , NS has detected a logical ISL port in TI zone in fabric . Routing may not be setup correctly. Probable Cause Indicates that a logical ISL is detected in the TI zone. Recommended Action Remove the LISL port from the TI zone because the routing may not be set up correctly.
76 NS-1011 NS-1011 Message , [NS-1011], ,, WARNING, , NS has detected a failover flag disabled TI zone in a base switch in fabric id . Probable Cause Indicates that a failover flag has disabled TI zone in a base switch fabric. Recommended Action Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not be setup correctly.
Chapter NSM System Messages 77 NSM-1001 Message , [NSM-1001], ,, INFO, , Interface is online. Probable Cause Indicates that the specified interface is online after the protocol dependencies are resolved. Recommended Action No action is required. Severity INFO NSM-1002 Message , [NSM-1002], ,, INFO, , Interface is protocol down.
77 NSM-1003 NSM-1003 Message , [NSM-1003], ,, INFO, , Interface is link down. Probable Cause Indicates that the specified interface is offline because the link is down. Recommended Action Check whether the connectivity between the peer ports is proper, and the remote link is up using the show interface command.
NSM-1007 77 NSM-1007 Message , [NSM-1007], ,, INFO, , Chassis is . Probable Cause Indicates whether chassis is enabled or disabled. Recommended Action No action is required. Severity INFO NSM-1008 Message , [NSM-1008], ,, INFO, , Blade is . Probable Cause Indicates whether the specified blade is enabled or disabled. Recommended Action No action is required.
77 NSM-1011 NSM-1011 Message , [NSM-1011], ,, INFO, , OperationalEndpointMode changed from to for interface . Probable Cause Indicates that the interface Operational Endpoint mode has been changed. Recommended Action No action is required. Severity INFO NSM-1012 Message , [NSM-1012], ,, INFO, , VLAN classifier group is created.
NSM-1015 77 NSM-1015 Message , [NSM-1015], ,, INFO, , VLAN classifier rule is deleted. Probable Cause Indicates that the specified VLAN classifier rule has been deleted. Recommended Action No action is required. Severity INFO NSM-1016 Message , [NSM-1016], ,, INFO, , VLAN classifier rule is on VLAN classifier group .
77 NSM-1019 NSM-1019 Message , [NSM-1019], ,, INFO, , Interface is administratively up. Probable Cause Indicates that the administrative status of the specified interface has changed to up. Recommended Action No action is required. Severity INFO NSM-1020 Message , [NSM-1020], ,, INFO, , Interface is administratively down.
Chapter ONMD System Messages 78 ONMD-1000 Message , [ONMD-1000], ,, INFO, , LLDP is enabled. Probable Cause Indicates that the Link Layer Discovery Protocol (LLDP) is enabled globally. Recommended Action No action is required. Severity INFO ONMD-1001 Message , [ONMD-1001], ,, INFO, , LLDP is disabled. Probable Cause Indicates that LLDP is disabled globally. Recommended Action No action is required.
78 ONMD-1004 Recommended Action Severity No action is required. INFO ONMD-1004 Message , [ONMD-1004], ,, INFO, , LLDP is disabled on interface . Probable Cause Indicates that LLDP is disabled on the specified interface. Recommended Action No action is required. Severity INFO ONMD-1005 Message , [ONMD-1005], ,, INFO, , Using auto-sense on interface to update DCBX version.
Chapter PDM System Messages 79 PDM-1001 Message , [PDM-1001], ,, WARNING, , Failed to parse the pdm config. Probable Cause Indicates the parity data manager (PDM) process could not parse the configuration file. This might be caused by a missing configuration file during the installation. Recommended Action Run the firmwareDownload command to reinstall the firmware.
79 PDM-1004 PDM-1004 Message , [PDM-1004], ,, WARNING, , PDM memory shortage. Probable Cause Indicates the parity data manager (PDM) process ran out of memory. Recommended Action Reboot or power cycle the switch. Severity If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1008 Recommended Action Severity 79 Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1008 Message , [PDM-1008], ,, WARNING, , Failed to get the number of U_Ports. Probable Cause Indicates the parity data manager (PDM) system call to getCfg failed.
79 PDM-1011 PDM-1011 Message , [PDM-1011], ,, WARNING, , File read failed: , Length(read=, expected=), errno=. Probable Cause Indicates the parity data manager (PDM) process could not read data from the specified file. Recommended Action Run the firmwareDownload command to reinstall the firmware.
PDM-1017 Recommended Action Severity 79 Run the firmwareDownload command to reinstall the firmware. If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. WARNING PDM-1017 Message , [PDM-1017], , FFDC, CRITICAL, , System (): . Probable Cause Indicates the specified system call failed.
79 PDM-1021 PDM-1021 Message , [PDM-1021], ,, WARNING, , Failed to download area port map. Probable Cause Indicates a system call failed. Recommended Action Run the firmwareDownload command to reinstall the firmware. Severity If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
PDM-1025 Recommended Action Severity 79 Configure DNS with IPv4 addresses. WARNING PDM-1025 Message , [PDM-1025], ,, WARNING, , IPv6 is configured for LDAP. Probable Cause Indicates that the parity data manager (PDM) cannot synchronize with its peer because the LDAP server is configured for IPv6 addresses. IPv6 is not supported by older firmware. Recommended Action Configure the LDAP server with IPv4 addresses.
79 540 PDM-1026 Fabric OS Message Reference 53-1002448-01
Chapter PDTR System Messages 80 PDTR-1001 Message , [PDTR-1001], ,, INFO, , . Probable Cause Indicates information has been written to the panic dump files. The watchdog register codes are as follows: • 0x10000000 bit set means that the watch dog timer (WDT) forced a core reset. • 0x20000000 bit set means that the WDT forced a chip reset. • All other code values are reserved.
80 542 PDTR-1002 Fabric OS Message Reference 53-1002448-01
Chapter PLAT System Messages 81 PLAT-1000 Message , [PLAT-1000], , FFDC, CRITICAL, , Probable Cause Indicates nonrecoverable PCI errors have been detected. Recommended Action The system will be faulted and might automatically reboot. If the system does not reboot, then try issuing the reboot command from a command-line prompt.
81 PLAT-1003 Recommended Action Severity Reboot the CP if it does not reboot itself. Reseat the CP if rebooting does not solve the problem. If the problem still persists, then replace the CP. CRITICAL PLAT-1003 Message , [PLAT-1003], , FFDC, CRITICAL, , Slot C/BE: ADBUS: misc_intr . Probable Cause Indicates a PCI bus hang was detected.
Chapter PMGR System Messages 82 PMGR-1001 Message , [PMGR-1001], , INFO, , Attempt to create switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully created. Recommended Action No action is required. Severity INFO PMGR-1002 Message , [PMGR-1002], , WARNING, , Attempt to create switch failed. Error message: .
82 PMGR-1005 Recommended Action Severity No action is required. WARNING PMGR-1005 Message , [PMGR-1005], , INFO, , Attempt to move port(s) to switch succeeded. Probable Cause Indicates the successful attempt to move the ports to the specified switch. Recommended Action No action is required.
PMGR-1009 Recommended Action Severity 82 No action is required. WARNING PMGR-1009 Message , [PMGR-1009], , INFO, ,Attempt to change the base switch to switch succeeded. Probable Cause Indicates the successful change of the base switch. Recommended Action No action is required. Severity INFO PMGR-1010 Message , [PMGR-1010], , WARNING, , Attempt to change the base switch to switch failed.
82 548 PMGR-1011 Fabric OS Message Reference 53-1002448-01
Chapter PORT System Messages 83 PORT-1003 Message , [PORT-1003], ,, WARNING, , Port Faulted because of many Link Failures Probable Cause Indicates that the specified port is now disabled because the link on this port had multiple failures that exceeded an internally set threshold on the port. This problem is typically related to hardware.
83 PORT-1006 Recommended Action Severity Invoke the portCfgLport command to clear the L_port configuration. WARNING PORT-1006 Message , [PORT-1006], ,, INFO, , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended Action No action is required.
PORT-1010 Recommended Action Severity 83 No action is required. INFO PORT-1010 Message , [PORT-1010], ,, INFO, , Port (ID: ) QOS is disabled. Probable Cause The Port QOS is disabled because the port currently has Best Effort Setting that requires QOS to be disabled on a 4G or 8G long distance platform. Recommended Action This is normal; no action required.
83 552 PORT-1010 Fabric OS Message Reference 53-1002448-01
Chapter PS System Messages 84 PS-1000 Message , [PS-1000], , FFDC, CRITICAL, , Failed to initialize Advanced Performance Monitoring. Probable Cause Indicates an unexpected software error has occurred in Advanced Performance Monitoring (APM). The performance monitor has failed to initialize.
84 PS-1003 PS-1003 Message , [PS-1003], ,, WARNING, , Failed to set end-to-end monitoring mask on ISL ports. Probable Cause Indicates that the restoring configuration has failed to set the end-to-end monitoring mask on at least one ISL port. Recommended Action No action is required. End-to-end monitoring is not supported on ISL ports when ISL monitoring is enabled. ISL monitoring can only be disabled through the Fabric Access API.
PS-1007 84 PS-1007 Message , [PS-1007], ,, WARNING, , Failed to add fabricmode toptalker on domain=. . Probable Cause Indicates that FCR or McData mode is enabled on this particular fabric. Recommended Action No action required. Top Talker cannot be installed on fabric with FC router or McData mode enabled. In case if the top talker has to be installed on fabric, FC router and McData mode has to be disabled.
84 556 PS-1009 Fabric OS Message Reference 53-1002448-01
Chapter PSWP System Messages 85 PSWP-1001 Message , [PSWP-1001], ,, INFO, , PID for port and port are swapped. New PID for port is and port is . Probable Cause Indicates that the portSwap command has been issued.
85 PSWP-1004 PSWP-1004 Message , [PSWP-1004], ,, INFO, , Blade Swap complete for slots and . Probable Cause Indicates that the bladeSwap command has been issued. Recommended Action No action is required.
Chapter RAS System Messages 86 RAS-1001 Message , [RAS-1001], ,, INFO, , First failure data capture (FFDC) event occurred. Probable Cause Indicates that a first failure data capture (FFDC) event occurred and the failure data has been captured. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider.
86 RAS-1005 RAS-1005 Message , [RAS-1005], , FFDC, WARNING, , Software 'assert' error detected. Probable Cause Indicates an internal software error. Recommended Action Execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider.
RAS-2002 86 RAS-2002 Message , [RAS-2002], , INFO, , Audit message log is disabled. Probable Cause Indicates that the audit message log has been disabled. Recommended Action No action is required. Severity INFO RAS-2003 Message , [RAS-2003], , INFO, , Audit message class configuration has been changed to .
86 RAS-3003 RAS-3003 Message , [RAS-3003], , WARNING, , USB storage device was unplugged before it was disabled. Probable Cause Indicates that the USB storage device was unplugged before it was disabled. Recommended Action Disable the USB storage device using the usbstorage -d command before unplugged it from the system. Severity WARNING RAS-3004 Message , [RAS-3004], , INFO, , USB storage device disabled.
Chapter RCS System Messages 87 RCS-1001 Message , [RCS-1001], ,, INFO, , RCS has been disabled. Some switches in the fabric do not support this feature. Probable Cause Indicates that the RCS feature has been disabled on the local switch because not all switches in the fabric support RCS or the switch is in nonnative mode. Recommended Action Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.
87 RCS-1004 RCS-1004 Message , [RCS-1004], ,, ERROR, , Application() not registered.() Probable Cause Indicates that a specified application did not register with RCS. Recommended Action Run the haShow command to view the HA state. Run the haDisable and the haEnable commands. Run the rcsInfoShow command to view RCS capability on the fabric. RCS is supported in Fabric OS v2.6, v3.1 and later, and v4.1 and later.
RCS-1007 87 If the reject is in the SFC phase, check if the application license exists for the remote domain and if the application data is compatible. Severity INFO RCS-1007 Message , [RCS-1007], ,, ERROR, , Zone DB size and propogation overhead exceeds domain 's maximum supported Zone DB size . Retry after reducing the Zone DB size. Probable Cause Indicates that a domain cannot handle the zone database being committed.
87 RCS-1010 RCS-1010 Message , [RCS-1010], ,, ERROR, , Domain is RCS incapable. Disabled E-port(s) connected to this domain. Probable Cause Indicates the remote domain is non-RCS and necessary action need to be taken to join RCS fabric. Recommended Action Configure the remote domain as RCS capable switch.
Chapter RKD System Messages 88 RKD-1001 Message , [RKD-1001], ,, INFO, , operation . Target: , Initiator: , LUN ID: .\n SessionId:/ Probable Cause Indicates that a First time encryption/re-key/Write Metadata was started/completed/cancelled. Recommended Action No action is required.
88 RKD-1004 Recommended Action Severity Correct the error and resume. CRITICAL RKD-1004 Message , [RKD-1004], ,, INFO, , Message: . Probable Cause Indicates the generic rekey message. Recommended Action No action is required. Severity INFO RKD-1005 Message , [RKD-1005], ,, WARNING, , LUN with LSN: does no have metadata.
Chapter RMOND System Messages 89 RMON-1001 Message , [RMON-1001], ,, INFO, , RMON rising threshold alarm from SNMP OID . Probable Cause Indicates that the threshold level has exceeded for the sample type of the remote monitoring (RMON) alarm. Recommended Action Check the traffic on the interface using the show interface command.
89 570 RMON-1002 Fabric OS Message Reference 53-1002448-01
Chapter RPCD System Messages 90 RPCD-1001 Message , [RPCD-1001], ,, WARNING, , Authentication Error: client \"\" has bad credentials: Probable Cause Indicates an authentication error was reported. The specified client IP address has faulty credentials. Recommended Action Enter the correct user name and password from the Fabric Access API host.
90 RPCD-1004 RPCD-1004 Message , [RPCD-1004], ,, WARNING, , Invalid certificate file. Secure RPCd is disabled. Probable Cause Indicates the SSL certificate file has been corrupted. Recommended Action To enable RPCD in Secure mode, install a valid SSL certificate in the switch. Severity WARNING RPCD-1005 Message , [RPCD-1005], ,, WARNING, , Missing private key file. Secure RPCd is disabled.
Chapter RTE System Messages 91 RTE-1001 Message , [RTE-1001], ,, ERROR, , Detected route inconsistency. If connectivity issues arise, all ISLs connected to this chassis need to be bounced to recover. Probable Cause Indicates that the constraints that are used to determine the paths for Dynamic Path Selection (DPS) are not synchronized from active control processor (CP) to standby CP during the failover. This event causes route inconsistencies.
91 574 RTE-1001 Fabric OS Message Reference 53-1002448-01
Chapter RTWR System Messages 92 RTWR-1001 Message , [RTWR-1001], ,, ERROR, , RTWR 0x, 0x, 0x, 0x, 0x Probable Cause Indicates that an error has occurred in the RTWR. The message provides the name of the routine having the error, and more specific error information. The values from 1 through 5 provide more information. Recommended Action No action is required.
92 RTWR-1003 RTWR-1003 Message , [RTWR-1003], ,, INFO, , : RTWR retry to domain , iu_data Probable Cause Indicates the number of times the RTWR has failed to get a response. Recommended Action Run the dom command to verify that the specified domain ID is reachable.
Chapter SCN System Messages 93 SCN-1001 Message Probable Cause , [SCN-1001], , FFDC, CRITICAL, , SCN queue overflow for process . Indicates that an attempt to write a state change notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or the system being busy. Some valid values for daemon name are listed below.
93 SCN-1002 SCN-1002 Message , [SCN-1002], , FFDC, ERROR, , SCN queue overflow for process . Probable Cause Indicates that an attempt to write a State Change Notification (SCN) message to a specific queue has failed because the SCN queue for the specified daemon name is full. This might be caused by the daemon hanging or the system being busy. The following are some of the valid values for the daemon name.
Chapter SEC System Messages 94 SEC-1001 Message , [SEC-1001], ,, ERROR, , RCS process fails: . Probable Cause Indicates that the reliable commit service (RCS) process failed to complete. RCS is a mechanism for transferring data from one switch to other switches within the fabric. RCS ensures that either all or none of the switches commit to the database.
94 SEC-1003 SEC-1003 Message , [SEC-1003], ,, WARNING, , Fail to download security data to domain after retries. Probable Cause Indicates the specified domain has failed to download security data after the specified number of attempts, and that the failed switch encountered an error accepting the database download. The primary switch will segment the failed switch after 30 tries.
SEC-1007 94 SEC-1007 Message , [SEC-1007], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message. Recommended Action Check for unauthorized access to the switch through the API connection.
94 SEC-1016 Recommended Action Severity Resolve the above specifed error by executing the command only from Primary FCS. ERROR SEC-1016 Message , [SEC-1016], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish SSH connection. Probable Cause Indicates a security violation was reported. The IP address of the unauthorized host is displayed in the message.
SEC-1025 94 SEC-1025 Message , [SEC-1025], ,, ERROR, , Invalid IP address () detected. Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
94 SEC-1029 SEC-1029 Message , [SEC-1029], ,, ERROR, , Invalid character in . Probable Cause Indicates a corruption occurred during the distribution of the security database. This can occur only when the primary fabric configuration server (FCS) distributes the security database to the other switches in the fabric, then local validation finds the error in the security database. This is a rare occurrence.
SEC-1032 94 SEC-1032 Message , [SEC-1032], ,, ERROR, , Empty FCS list is not allowed. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
94 SEC-1035 SEC-1035 Message , [SEC-1035], ,, ERROR, , Invalid device WWN . Probable Cause Indicates the specified world wide name (WWN) is invalid. Recommended Action Enter the correct WWN value. Severity ERROR SEC-1036 Message , [SEC-1036], ,, ERROR, , Device name is invalid due to a missing colon.
SEC-1040 94 SEC-1040 Message , [SEC-1040], ,, ERROR, , Invalid portlist (). Cannot combine * with port member in the same portlist. Probable Cause Indicates the port list contains the wildcard asterisk (*) character. You cannot use the asterisk in a port list. Recommended Action Enter the port list values without any wildcards.
94 SEC-1044 Recommended Action Severity Use valid syntax when entering port ranges. ERROR SEC-1044 Message , [SEC-1044], ,, ERROR, , Duplicate member in (). Probable Cause Indicates the specified member is a duplicate in the input list. The list can be a policy list or a switch member list. Recommended Action Do not specify any duplicates.
SEC-1049 94 SEC-1049 Message , [SEC-1049], ,, ERROR, , Invalid switch name . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
94 SEC-1052 SEC-1052 Message , [SEC-1052], ,, ERROR, , Invalid input. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
SEC-1055 94 SEC-1055 Message , [SEC-1055], ,, ERROR, , Invalid FCS list . Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
94 SEC-1059 SEC-1059 Message , [SEC-1059], ,, ERROR, , Fail to to flash. Probable Cause Indicates the operation failed when writing to flash. Recommended Action Run the supportFtp - e command to FTP files from the switch and remove them from the flash. Severity ERROR SEC-1062 Message , [SEC-1062], ,, ERROR, , Invalid number of Domains in Domain List.
SEC-1065 94 SEC-1065 Message , [SEC-1065], ,, ERROR, , Invalid character in list. Probable Cause Indicates the input list has an invalid character. Recommended Action Enter valid input. Severity ERROR SEC-1069 Message , [SEC-1069], ,, ERROR, , Security Database is corrupted. Probable Cause Indicates the security database is corrupted for unknown reasons.
94 SEC-1073 SEC-1073 Message , [SEC-1073], ,, ERROR, , No FCS policy in list! Probable Cause Indicates the specific policy type is empty. The security database is corrupted for unknown reasons. Recommended Action Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
SEC-1076 94 SEC-1076 Message , [SEC-1076], ,, ERROR, , NoNodeWWNZoning option has been changed. Probable Cause Indicates the NoNodeWWNZoning option has been changed. If the option is turned on, a zone member can be added using node WWNs, but the member will not be able to communicate with others nodes in the zone. Recommended Action Re-enable the current zone configuration for the change to take effect.
94 SEC-1080 Recommended Action Severity Run the command again using a valid policy name. ERROR SEC-1080 Message , [SEC-1080], ,, ERROR, , Operation denied. Please, use secModeEnable command. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1083 94 SEC-1083 Message , [SEC-1083], ,, ERROR, , Name already exists. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
94 SEC-1087 Recommended Action Severity Reduce the number of entries in some policies to decrease the security database size. ERROR SEC-1087 Message , [SEC-1087], ,, ERROR, , The security database is larger than the data distribution limit of fabric bytes. Probable Cause Indicates the security database has more data than can be distributed to some of the switches in the fabric.
SEC-1090 94 SEC-1090 Message , [SEC-1090], ,, ERROR, , SCC list contains FCS member. Please remove member from the FCS policy first. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database.
94 SEC-1093 SEC-1093 Message , [SEC-1093], ,, ERROR, , New FCS list must have at least one member in common with current FCS list. Probable Cause Indicates the new fabric configuration server (FCS) list does not have a common member with the existing FCS list. Recommended Action Resubmit the command with at least one member of the new FCS list in common with the current FCS list.
SEC-1096 94 SEC-1096 Message , [SEC-1096], ,, ERROR, , Failed to delete because . Probable Cause Indicates a policy cannot be removed because deleting it would result in invalid security policy configuration. Recommended Action Verify the security policy configuration requirements and remove any policies that require the policy you want to remove first.
94 SEC-1100 Recommended Action Severity Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. ERROR SEC-1100 Message , [SEC-1100], ,, ERROR, , FCS switch present. Command terminated. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1104 94 SEC-1104 Message , [SEC-1104], ,, ERROR, , Fail to get primary . Probable Cause Indicates the switch failed to get either the primary certificate or a primary public key. Recommended Action Verify the primary switch has a valid certificate installed and retry the operation. If a valid certificate is not installed, install a certificate by following the procedure specified in the Secure Fabric OS Administrator's Guide.
94 SEC-1108 Recommended Action Severity Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. INFO SEC-1108 Message , [SEC-1108], ,, ERROR, , Fail to reset stamp on all switches.
SEC-1112 94 SEC-1112 Message , [SEC-1112], ,, ERROR, , FCS list must be the first entry in the Active Security policies, and the same as the current active FCS list in the switch. Probable Cause Indicates that either a security policy download is attempted with an active policy that does not have the fabric configurations server (FCS) policy as the first policy or the FCS policy is not same as the current FCS policy on the switch.
94 SEC-1116 Recommended Action Severity Run the secFabricShow command to verify that all switches in fabric are in the ready state. When all switches are in the ready state, retry the operation. ERROR SEC-1116 Message , [SEC-1116], ,, ERROR, , Fail to commit failover. Probable Cause Indicates there has been a corruption during the distribution of the security database.
SEC-1119 94 SEC-1119 Message , [SEC-1119], ,, INFO, , Secure mode has been enabled. Probable Cause Indicates the secure Fabric OS was enabled by the secModeEnable command. Recommended Action Verify the security event was planned. If the security event was planned, there is no action required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
94 SEC-1124 Recommended Action Severity No action is required. INFO SEC-1124 Message , [SEC-1124], ,, INFO, , Secure Mode is off. Probable Cause Indicates that a secure mode disable is attempted in a non-secure fabric. Recommended Action No action is required. Severity INFO SEC-1126 Message , [SEC-1126], ,, INFO, , Secure mode has been disabled.
SEC-1136 Recommended Action Severity 94 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-1136 Message , [SEC-1136], ,, ERROR, , Failed to verify signature .
94 SEC-1139 Recommended Action Severity Verify that the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-1139 Message , [SEC-1139], ,, ERROR, , The RSNMP_POLICY cannot exist without the WSNMP_POLICY.
SEC-1146 Recommended Action Severity 94 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-1146 Message , [SEC-1146], ,, INFO, , PID changed: . Probable Cause Indicates the PID format of the switch was changed either to extended-edge PID or from extended-edge PID.
94 SEC-1155 Recommended Action Severity Reduce the size of the policy database. INFO SEC-1155 Message , [SEC-1155], ,, INFO, , PID change failed: . Probable Cause Indicates that either the defined or active policy was too large after modifying the index/area ID. The status values can be either defined, active, or both. A negative value means that a policy set was failed by the daemon.
SEC-1158 94 SEC-1158 Message , [SEC-1158], ,, INFO, , Invalid name . Probable Cause Indicates the specified name is invalid. The name can be a policy name or a switch name. Recommended Action Enter a valid name. Severity INFO SEC-1159 Message , [SEC-1159], ,, INFO, , Non_Reachable domain .
94 SEC-1164 Recommended Action Severity Do not use lockdown option with the secModeEnable command when a switch is already in secure mode. ERROR SEC-1164 Message , [SEC-1164], ,, ERROR, , Lockdown option cannot be applied on a non-FCS switch. Probable Cause Indicates the attempt to enable security is made on a switch that is not present in the fabric configuration server (FCS) list.
SEC-1167 94 SEC-1167 Message , [SEC-1167], ,, ERROR, , Another FCS failover is in process. Command terminated. Probable Cause Indicates that because another failover is already in progress, this failover attempt cannot proceed. Recommended Action Verify the security event was planned. If the security event was planned, retry fabric configurations server (FCS) failover after current failover has completed, if this switch should become primary FCS.
94 SEC-1171 SEC-1171 Message , [SEC-1171], ,, ERROR, , Disabled secure mode due to invalid security object. Probable Cause Indicates the switch is segmented, and secure mode is disabled on the switch because there was no license present or no public key infrastructure (PKI) objects. Recommended Action Run the pkiShow command to determine whether all PKI objects exist. If they do not exist, run the pkiCreate command to create them for the switch.
SEC-1175 Recommended Action Severity 94 Verify all switches in the fabric are in time synchronization with the primary and that no external entity is trying to access the fabric. When verification is complete, retry the operation. ERROR SEC-1175 Message , [SEC-1175], ,, ERROR, , Failed to install zone data. Probable Cause Indicates the zone database could not be installed on the switch.
94 SEC-1182 Recommended Action Severity No action is required. INFO SEC-1182 Message , [SEC-1182], ,, INFO, , Recovered accounts. Probable Cause Indicates the specified number of accounts has been recovered from backup. Recommended Action No action is required. Severity INFO SEC-1183 Message , [SEC-1183], ,, ERROR, , Policy to binary conversion error: Port is out range.
SEC-1185 94 SEC-1185 Message , [SEC-1185], ,, INFO, , switch DB. Probable Cause Indicates the switch database was enabled or disabled as the secondary authentication, accounting, and authorization (AAA) mechanism when the Remote Authentication Dial-in User Service (RADIUS) / Lightweight Directory Access Protocol (LDAP) is the primary AAA mechanism Recommended Action No action is required.
94 SEC-1188 SEC-1188 Message , [SEC-1188], ,, INFO, , Security violation: Unauthorized device tries to FLOGI to index/area of switch . Probable Cause Indicates a device connection control (DCC) security violation was reported. The specified device attempted to login using fabric login (FLOGI) to an unauthorized port. The DCC policy correlates specific devices to specific port locations.
SEC-1191 94 SEC-1191 Message , [SEC-1191], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish HTTP connection. Probable Cause Indicates an HTTP security violation was reported. The specified unauthorized host attempted to establish an HTTP connection. Recommended Action Determine whether the host IP address specified in the message can be used to manage the fabric through an HTTP connection.
94 SEC-1194 SEC-1194 Message , [SEC-1194], ,, WARNING, , This switch does not have all the required PKI objects correctly installed. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database.
SEC-1197 94 SEC-1197 Message , [SEC-1197], ,, INFO, , Changed account . Probable Cause Indicates the specified account has changed. Recommended Action No action is required. Severity INFO SEC-1198 Message , [SEC-1198], ,, INFO, , Security violation: Unauthorized host with IP address tries to establish API connection. Probable Cause Indicates an API security violation was reported.
94 SEC-1201 Recommended Action Severity Check the MS policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy. If the MS policy does not allow the connection, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy.
SEC-1250 94 SEC-1250 Message , [SEC-1250], ,, WARNING, , DCC enforcement API failed: err=, key= Probable Cause Indicates an internal error caused the device connection control (DCC) policy enforcement to fail. Recommended Action Retry the failed security command.
94 SEC-1301 Recommended Action Severity Turn off VC-encoded mode before enabling security. INFO SEC-1301 Message , [SEC-1301], ,, INFO, , This switch is in interop mode. Security is not supported. Probable Cause Indicates the switch is interop-mode enabled. Recommended Action Disable interop-mode using the interopMode command before enabling the Secure Fabric OS feature.
SEC-1304 94 SEC-1304 Message , [SEC-1304], ,, INFO, , This switch has no security license. Probable Cause Indicates there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configuration server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence.
94 SEC-1307 SEC-1307 Message , [SEC-1307], ,, INFO, , Got response from server . Probable Cause Indicates that after some servers timed out, the specified remote authentication dial-in user service (RADIUS/LDAP) server responded to a switch request. Recommended Action If the message appears frequently, move the responding server to the top of the RADIUS/LDAP server configuration list using the aaaConfig command.
SEC-1311 Recommended Action Severity 94 Retry the command when the fabric is stable. INFO SEC-1311 Message , [SEC-1311], ,, ERROR, , Security mode cannot be enabled because one or more of the password policies is not set to default value. Probable Cause Indicates the security enable failed on the fabric because one or more switches in the fabric have password policies that are not set to the default value.
94 SEC-1314 SEC-1314 Message , [SEC-1314], ,, ERROR, , Reading IP address from EM failed. Probable Cause Indicates the call to the EM module to retrieve the IP address failed. Recommended Action Restart the system to fix this error. If the problem persists contact your switch service provider.
SEC-1318 Recommended Action Severity 94 If a policy conflict exists, resolve it, then wait for the fabric to become stable. Retry the distribution. INFO SEC-1318 Message , [SEC-1318], ,, INFO, , Transaction rejected due to inconsistent fabric. Probable Cause Indicates that some domains detected an inconsistent fabric. Recommended Action Resolve the policy conflict, if there is one, then wait for the fabric to stabilize. Retry the distribution.
94 SEC-1322 Recommended Action Severity Verify the security event was planned. If the security event was planned, run the fddcfg --fabwideset “” command or ad --clear command to clear the fabric wide consistency configuration or AD configuration and retry the secModeEnable command. ERROR SEC-1322 Message , [SEC-1322], ,, WARNING, , Some DCC policy is too large, distribution cancelled.
SEC-1325 94 SEC-1325 Message , [SEC-1325], ,, ERROR, , Security enforcement: Switch connecting to port is not authorized to stay in fabric. Probable Cause Indicates that because of a switch connection control (SCC) policy violation, the switch is being disabled on the specified port. Recommended Action No action is required unless the switch must remain in the fabric.
94 SEC-1329 Recommended Action Severity Verify the security event was planned. If the security event was planned, run the authUtil --policy passive command to disable the Authentication Policy and retry the secModeEnable command. ERROR SEC-1329 Message , [SEC-1329], ,, ERROR, , IPFilter enforcement: Failed to enforce ipfilter policy of type because of .
SEC-1332 94 SEC-1332 Message , [SEC-1332], ,, ERROR, , Fabric wide policy is conflicting as is present in the fabric wide policy and 5.3 or 5.2 switches present in the fabric. Probable Cause Indicates the fabric-wide policy is conflicting. Recommended Action Remove either the FCS from the fabric-wide policy, or remove 5.3 and 5.2 switches from the fabric, or set the fabric-wide mode for FCS as Strict.
94 SEC-1336 Recommended Action Severity No action is required. The domain is denied by disallowing all its E-ports connected to the fabric. If the domain should be allowed to merge with the fabric, then resolve the issue by making the conflicting policies the same. WARNING SEC-1336 Message , [SEC-1336], ,, WARNING, , policy is conflicting with domain .
SEC-3036 94 SEC-3036 Message , [SEC-3036], , INFO, , Event: ipfilter, Status: failed, Info: Failed to save changes for ipfilter policies. Probable Cause Indicates that that the specified IP filter policy has not been saved. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required.
94 SEC-3050 Recommended Action Severity Check for unauthorized access to the switch through the specified protocol connection. INFO SEC-3050 Message , [SEC-3050], , INFO, , Event: , Status: success, Info: . Probable Cause Indicates the specified sshutil operation was performed. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
SEC-3063 Recommended Action Severity 94 No action is required. INFO SEC-3063 Message , [SEC-3063], , INFO, , Role is copied from . Probable Cause Indicates that the specified role name has been copied from the source role. Recommended Action No action is required.
94 SEC-3067 Recommended Action Severity No action is required. INFO SEC-3067 Message , [SEC-3067], , WARNING, , Invalid Cipher list . Probable Cause Indicates that the input cipher list is an invalid string. Recommended Action Invalid cipher list input, therefore reverted to previous cipher list.
Chapter SFLO System Messages 95 SFLO-1001 Message , [SFLO-1001], ,, INFO, , sFlow is globally. Probable Cause Indicates that sFlow is globally enabled or disabled. Recommended Action No action is required. Severity INFO SFLO-1002 Message , [SFLO-1002], ,, INFO, , sFlow is for port . Probable Cause Indicates that sFlow is enabled or disabled on the specified port.
95 SFLO-1005 Recommended Action Severity No action is required. INFO SFLO-1005 Message , [SFLO-1005], ,, INFO, , sFlow sampling rate on port is changed to . Probable Cause Indicates that the sFlow sampling rate has been changed on the specified port. Recommended Action No action is required.
SFLO-1008 Recommended Action Severity 95 No action is required.
95 644 SFLO-1008 Fabric OS Message Reference 53-1002448-01
Chapter SNMP System Messages 96 SNMP-1001 Message , [SNMP-1001], ,, ERROR, , SNMP service is not available . Probable Cause Indicates that the Simple Network Management Protocol (SNMP) service could not be started because of the specified reason. Therefore, you will not be able to query the switch through SNMP. Recommended Action Verify that the IP address for the Ethernet and Fibre Channel interface is set correctly.
96 SNMP-1004 SNMP-1004 Message , [SNMP-1004], , FFDC, ERROR, , Incorrect SNMP configuration. Probable Cause Indicates that the SNMP configuration is incorrect and therefore the SNMP service will not work correctly. Recommended Action Change the SNMP configuration to default using the snmpConfig --default command.
SNMP-1008 96 SNMP-1008 Message , [SNMP-1008], ,, INFO, , The last device change happened at: . Probable Cause Indicates the last device change time. Recommended Action Execute the nsshow command to view the current device status. Severity INFO SNMP-1009 Message , [SNMP-1009], ,, INFO, , Port traps are on port .
96 648 SNMP-1009 Fabric OS Message Reference 53-1002448-01
Chapter SPC System Messages 97 SPC-1001 Message , [SPC-1001], ,, INFO, , S, Cryptographic operation enabled. Probable Cause Indicates the cryptographic operation is enabled on an encryption engine. Recommended Action No action is required. Severity INFO SPC-1002 Message , [SPC-1002], ,, INFO, , S, Cryptographic operation disabled.
97 SPC-2001 SPC-2001 Message , [SPC-2001], ,, ERROR, , S, : Crypto error asserted by Vader/OB1 0x. Probable Cause Indicates the Crypto error is asserted by Field-Programmable Gate Array (FPGA). Recommended Action No action is required.
SPC-2005 Recommended Action Severity 97 No action is required. ERROR SPC-2005 Message , [SPC-2005], ,, INFO, , S, : FPGA firmware download success: 0x. Probable Cause Indicates the FPGA download was successful. Recommended Action No action is required.
97 SPC-2009 Recommended Action Severity No action is required. INFO SPC-2009 Message , [SPC-2009], ,, CRITICAL, , S, : Tamper event: User zeroization. Probable Cause Indicates the Tamper event triggered due to a user zeroize request. The Encryption Engine (EE) is zeroized. Recommended Action Execute the cryptocfg --initEE and cryptocfg --regEE commands.
SPC-2012 97 SPC-2012 Message , [SPC-2012], ,, INFO, , S, : User zeroization command completed successfully. Tamper INT status . Probable Cause Indicates the User zeroization command has completed successfully. The Encryption Engine (EE) is zeroized. Recommended Action Execute the cryptocfg --initEE and cryptocfg --regEE commands.
97 SPC-2041 Recommended Action Severity No action is required. ERROR SPC-2041 Message , [SPC-2041], ,, ERROR, , S, : Alloc freemsg block failed. Probable Cause Indicates an allocation failure for pool for switch board (SB) message. Recommended Action No action is required.
SPC-3001 Recommended Action Severity 97 No action is required. WARNING SPC-3001 Message , [SPC-3001], ,, ERROR, , S, : No input KEK for DEK inject, DEK: , KEK: . Probable Cause Indicates the wrapping KEK for the DEK to be injected does not exist within the EE Crypto Module.
97 SPC-3004 SPC-3004 Message , [SPC-3004], ,, ERROR, , S, : No output KEK for DEK create, KEK: . Probable Cause Indicates the output wrapping KEK for the DEK to be created does not exist within the EE Crypto Module. Recommended Action For opaque key vaults such as RKM, recover the missing Master Key to current or alternate position.
SPC-3007 Recommended Action Severity 97 For status code 14, complete primary KEK generation; otherwise, contact your switch service provider. ERROR SPC-3007 Message Probable Cause , [SPC-3007], ,, ERROR, , S, : DEK create error: , info: .
97 SPC-3010 SPC-3010 Message , [SPC-3010], ,, WARNING, , S, : SEK integrity failure during initialization. Probable Cause Indicates the Crypto Module internal Secret Encryption Key has been corrupted or has not been initialized. Recommended Action Execute the cryptocfg --initEE and cryptocfg --regEE commands.
SPC-3014 Recommended Action Severity 97 Contact your switch service provider for assistance. ERROR SPC-3014 Message , [SPC-3014], ,, ERROR, , S, : RNG compare failure: successive values match. Probable Cause Indicates the Crypto Module internal random number generator has failed. Recommended Action Contact your switch service provider for assistance.
97 660 SPC-3015 Fabric OS Message Reference 53-1002448-01
Chapter SPM System Messages 98 SPM-1001 Message , [SPM-1001], ,, ERROR, , Init fails: . Probable Cause Indicates the SPM has failed to initialize. Recommended Action Check the system resources and restart the switch. Severity ERROR SPM-1002 Message , [SPM-1002], ,, WARNING, , Generic SPM Warning: . Probable Cause Indiactes an SPM warning based on the reason displayed.
98 SPM-1005 Recommended Action Severity No action is required. INFO SPM-1005 Message , [SPM-1005], ,, INFO, , Set EE Control slot action . Probable Cause Indicates encryption engine (EE) control slot configuration. Recommended Action No action is required. Severity INFO SPM-1006 Message , [SPM-1006], ,, INFO, , Registered Certificate of type .
SPM-1009 Recommended Action Severity 98 No action is required. INFO SPM-1009 Message , [SPM-1009], ,, ERROR, , Certificate is missing. Probable Cause Indicates that a certificate is missing. Recommended Action Run the cryptocfg --initnode command. Severity ERROR SPM-1010 Message , [SPM-1010], ,, ERROR, , Key Vault Certificate is missing.
98 SPM-1013 Recommended Action Severity No action is required. INFO SPM-1013 Message , [SPM-1013], ,, ERROR, , Security database is out of sync. Probable Cause Indicates a failure to distribute security database. Recommended Action Use cryptocfg --sync -securitydb to manually sync security db.
SPM-1016 98 SPM-1016 Message , [SPM-1016], ,, WARNING, , Security database is out of sync. This warning can be ignored if the nodes in the EG are running different versions of FOS. Probable Cause Indicates a failure to distribute security database. Recommended Action Use the cryptocfg --sync -securitydb command to manually sync security db.
98 SPM-3004 SPM-3004 Message , [SPM-3004], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot enabled. Probable Cause Indicates an encryption engine was enabled. Recommended Action No action is required. Severity INFO SPM-3005 Message , [SPM-3005], ,, INFO, ,Event: cryptocfg Status: success, Info: EE in slot disabled. Probable Cause Indicates an encryption engine was disabled.
SPM-3008 98 SPM-3008 Message , [SPM-3008], ,, INFO, ,Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended Action No action is required. Severity INFO SPM-3009 Message , [SPM-3009], ,, INFO, ,Event: cryptocfg Status: success, Info: DH response accepted.
98 SPM-3012 SPM-3012 Message , [SPM-3012], ,, INFO, ,Event: cryptocfg Status: success, Info: key vault registered. Certificate label: \"\" Certificate file: \"\" IP address: . Probable Cause Indicates a key vault was registered. Recommended Action No action is required.
SPM-3016 Recommended Action Severity 98 No action is required. INFO SPM-3016 Message , [SPM-3016], ,, INFO, ,Event: cryptocfg Status: success, Info: Master key generated. Probable Cause Indicates a master key was generated. Recommended Action No action is required. Severity INFO SPM-3017 Message , [SPM-3017], ,, INFO, ,Event: cryptocfg Status: success, Info: Master key exported.
98 SPM-3020 Recommended Action Severity No action is required. INFO SPM-3020 Message , [SPM-3020], ,, INFO, , Event: cryptocfg Status: success, Info: System card with certificate label \"\" deregistered. Probable Cause Indicates a system card was de-registered. Recommended Action No action is required.
SPM-3024 Recommended Action Severity 98 No action is required. INFO SPM-3024 Message , [SPM-3024], ,, INFO, , Event: cryptocfg Status: success, Info: Quorum size set to . Probable Cause Indicates the quorum size was set. Recommended Action No action is required.
98 SPM-3028 Recommended Action Severity No action is required. INFO SPM-3028 Message , [SPM-3028], ,, INFO, , Event: SPM-EE state changed, Info: EE State: . Probable Cause Indicates an EE state has changed. Recommended Action No action is required. Severity INFO SPM-3029 Message , [SPM-3029], ,, INFO, , Event: KeyVault Connection Status: , Info:KAC_Connect: .
Chapter SS System Messages 99 SS-1000 Message , [SS-1000], ,, INFO, , supportSave has uploaded support information to the host with IP address . Probable Cause Indicates that the supportSave command was used to transfer support information to a remote location. Recommended Action No action is required.
99 SS-1003 SS-1003 Message , [SS-1003], ,, WARNING, , supportSave's operation to USB storage device aborted. Probable Cause Indicates that a USB operation error has occurred during execution of the supportSave command. Complete error information cannot always be displayed in this message because of possible errors in subcommands being executed by the supportSave command.
SS-1007 Recommended Action Severity 99 Restart the switch using the reboot command and then execute the supportSave command. WARNING SS-1007 Message , [SS-1007], ,, WARNING, , supportsave failed for the slot . Reason: No response from the blade in the specified slot for the given supportsave request. Probable Cause Indicates that there was no reponse from the blade in the specified slot for the given supportsave request.
99 676 SS-1009 Fabric OS Message Reference 53-1002448-01
Chapter SSMD System Messages 100 SSMD-1001 Message , [SSMD-1001], ,, ERROR, ,Failed to allocate memory: . Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Severity Restart or power cycle the switch.
100 SSMD-1004 SSMD-1004 Message , [SSMD-1004], ,, ERROR, , Failed to unlock semaphore mutex: (). Probable Cause Indicates that the specified function has failed to unlock the mutex (semaphore). Recommended Action Restart or power cycle the switch. Severity ERROR SSMD-1005 Message , [SSMD-1005], ,, ERROR, , SSM start up failed.
SSMD-1008 Recommended Action Severity 100 Try again after sometime. If the problem persists, execute the supportSave command and then restart or power cycle the switch. ERROR SSMD-1008 Message , [SSMD-1008], ,, ERROR, , Apptype TCAM Table full for Slot: chip:. Probable Cause Indicates that the application type TCAM table is full on the specified chip.
100 SSMD-1202 SSMD-1202 Message , [SSMD-1202], ,, WARNING, , QoS failed programming interface 0x 802.3x Pause flow control. Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for enforcing the interface 802.3x Pause flow control feature. Recommended Action Delete and reapply the QoS 802.3x Pause flow control policy using the qos flowcontrol command.
SSMD-1206 Recommended Action Severity 100 Delete and reapply the CEE Map ETS policy using the cee-map default command. If the problem persists, restart or power cycle the switch. WARNING SSMD-1206 Message , [SSMD-1206], ,, WARNING, , CEE failed programming CoS to PGID policy for CEE Map .
100 SSMD-1209 SSMD-1209 Message , [SSMD-1209], ,, WARNING, , QoS failed programming interface 0x CoS Mutation map. Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for enforcing the interface CoS Mutation mapping feature. Recommended Action Delete and reapply the QoS interface CoS Mutation policy using the qos cos-mutation command.
SSMD-1212 100 SSMD-1212 Message , [SSMD-1212], ,, WARNING, , QoS failed programming ASIC / Multicast Scheduler Control. Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for enforcing the multicast packet Scheduler Control feature. Recommended Action Delete and reapply the QoS multicast packet Scheduler Control policy using the qos queue multicast scheduler command.
100 SSMD-1216 Recommended Action Severity Delete and reapply the QoS CoS Tail Drop Threshold policy using the qos rcv-queue command. If the problem persists, restart or power cycle the switch. WARNING SSMD-1216 Message , [SSMD-1216], ,, WARNING, ,QoS failed programming interface 0x Pause. Probable Cause Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for enforcing the interface Pause feature.
SSMD-1302 Recommended Action Severity 100 No action is required. INFO SSMD-1302 Message , [SSMD-1302], ,, INFO, , CEE Map priority table is . Probable Cause Indicate that the priority groups (PGs) have been added to or removed from the specified CEE Map. Recommended Action No action is required.
100 SSMD-1306 Recommended Action Severity No action is required. INFO SSMD-1306 Message , [SSMD-1306], ,, INFO, , CEE Map priority group is PFC . Probable Cause Indicates that the specified PG PFC status has been changed. Recommended Action No action is required. Severity INFO SSMD-1307 Message , [SSMD-1307], ,, INFO, , access list is created.
SSMD-1310 Recommended Action Severity 100 No action is required. INFO SSMD-1310 Message , [SSMD-1310], ,, INFO, , ACL configured on interface . Probable Cause Indicates that the specified access list has been configured on the interface. Recommended Action No action is required.
100 SSMD-1314 Recommended Action Severity No action is required. INFO SSMD-1314 Message Probable Cause , [SSMD-1314], ,, INFO, , CEE Map precedence changed from to . Indicates that precedence of the specified CEE Map has been changed.Recommended Action No action is required.
SSMD-1318 Recommended Action Severity 100 No action is required. INFO SSMD-1318 Message , [SSMD-1318], ,, INFO, , ACL is being removed from interface . This operation could take a long time. Probable Cause Indicates that the specified access list is being removed from the interface. Recommended Action No action is required.
100 SSMD-1318 690 Fabric OS Message Reference 53-1002448-01
Chapter SULB System Messages 101 SULB-1001 Message , [SULB-1001], , WARNING, , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been started. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action Do not fail over or power down the system during firmware upgrade. Allow the firmwareDownload command to continue without disruption.
101 SULB-1004 SULB-1004 Message , [SULB-1004], ,, INFO, , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information. Severity INFO SULB-1005 Message , [SULB-1005], ,, INFO, , Current Active CP is preparing to failover. Probable Cause Indicates the active CP is about to restart.
SULB-1008 101 SULB-1008 Message , [SULB-1008], ,, INFO, , Standby CP booted successfully with new firmware. Probable Cause Indicates the standby CP has rebooted successfully. Recommended Action No action is required. The firmwareDownload command is progressing as expected. Severity Run the firmwareDownloadStatus command for more information.
101 SULB-1009 TABLE 7 694 Status messages and status codes (Continued) Status message Status code "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error." 0x59 “Sanity check failed because firmwareDownload is already in progress.
SULB-1009 TABLE 7 Status messages and status codes (Continued) Status message Status code "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.” 0x84 "Standby CP was not responding. The command is aborted.
101 SULB-1009 TABLE 7 Status messages and status codes (Continued) Status message Status code "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.” 0xac Table 8 lists additional firmwareDownload error messages and error codes. They provide more details on why firmwareDownload failed.
SULB-1009 TABLE 8 101 Error messages and error codes (Continued) Error message Error code “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed." 0x29 “The platform option is not supported.
101 SULB-1009 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server.
SULB-1010 101 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
101 SULB-1018 Recommended Action Severity Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider. ERROR SULB-1018 Message , [SULB-1018], , ERROR, , Firmwaredownload timed out in slot .
SULB-1022 101 SULB-1022 Message , [SULB-1022], ,, WARNING, , The blade in slot has rebooted successfully with new firmware. Probable Cause Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step in the firmwareDownload process. Recommended Action Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
101 SULB-1025 SULB-1025 Message , [SULB-1025], ,, WARNING, , The blade in slot will reboot with the new firmware. Probable Cause Indicates new firmware has been downloaded to the specified AP blade and that the AP blade will reboot to activate it. Recommended Action Wait for the blade to reboot.
SULB-1032 Recommended Action Severity 101 Wait for the operation to complete. WARNING SULB-1032 Message , [SULB-1032], , WARNING, , Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the co-CPU. Recommended Action Wait for the operation to complete.
101 SULB-1036 Probable Cause Indicates an error has occurred during the relocation of the internal image. The error may be caused by inconsistent internal firmware image. It may also be caused by the internal Ethernet or persistent storage hardware failure. Recommended Action Reset the switch. This will cause the internal image to be relocated again. If the problem persists, contact your switch service provider.
SULB-1039 101 SULB-1039 Message , [SULB-1039], , INFO, , CP has completed relocating the internal firmware image. Probable Cause Indicates that the firmwareDownload command process has been completed normally on the CP. Recommended Action Run the firmwareShow command to verify the firmware versions.
101 SULB-1043 Recommended Action Severity No action is required. The firmwareActivate command has completed as expected. Run the firmwareShow command to verify the firmware versions. INFO SULB-1043 Message , [SULB-1043], , INFO, , FirmwareActivation command failed. . Probable Cause Indicates the firmwareActivate command failed. The error string indicates why it failed.
Chapter SWCH System Messages 102 SWCH-1001 Message , [SWCH-1001], ,, ERROR, , Switch is not in ready state - Switch enable failed switch status= 0x, c_flags = 0x. Probable Cause Indicates the switch is enabled before it is ready. Recommended Action If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
102 SWCH-1004 SWCH-1004 Message , [SWCH-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = . Probable Cause Indicates a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command and then the slotPowerOn command.
SWCH-1008 Recommended Action 102 Based on the disable reason displayed, proper corrective action may to be required to restore the port. If the disable reason is due to insufficient frame buffers, reduce the distance or speed settings for the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port group must be disabled to make more buffers available for the link. Refer to the Fabric OS Administrator’s Guide for more information about buffers.
102 SWCH-1011 Refer to the Fabric OS Administrator’s Guide for more information. Severity WARNING SWCH-1011 Message , [SWCH-1011], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Trunk Area functionality. (active ver = , Trunk Area enabled on switch = <'1' if Trunk Area ports exist; Otherwise '0'>).
SWCH-1014 102 SWCH-1014 Message , [SWCH-1014], ,, INFO, , All Trunk Areas have been disabled. Probable Cause Indicates that all Trunk Areas have been disabled and the configuration file has been updated. Recommended Action No action is required. Severity INFO SWCH-1015 Message , [SWCH-1015], ,, WARNING, , .
102 SWCH-1018 Recommended Action Severity This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove the WWN-PID binding and re-enable the port and then run the wwnaddress --unbind wwn command. INFO SWCH-1018 Message , [SWCH-1018], ,, INFO, , Device flogis to port , Static persistent PID set, Requested area user bound to another port. Reject FLOGI.
SWCH-1021 102 SWCH-1021 Message , [SWCH-1021], ,, WARNING, , HA state out of sync: Standby CP (ver = ) does not support Dynamic area on default switch (Active CP version = ). Probable Cause Indicates the standby control processor (CP) does not support dynamic area on default switch.
102 SWCH-1022 714 Fabric OS Message Reference 53-1002448-01
Chapter SYSC System Messages 103 SYSC-1001 Message , [SYSC-1001], , FFDC, CRITICAL, , Failed to run :. Probable Cause Indicates that during the boot sequence, one of the programs does not run on the system. Recommended Action If the message is reported during a restart after new firmware has been loaded, try reloading the firmware using the firmwareDownload command.
103 SYSC-1004 It could also indicate that the current option number could not be read from the chassis option storage device (the world wide name (WWN) card). This message occurs only on the Brocade 24000 and 48000. Recommended Action Severity As indicated in the message, run the chassisConfig command to change to one that is valid on this platform running this firmware. Note that the chassisConfig option 1 should be valid for all platforms running any valid firmware.
Chapter SYSM System Messages 104 SYSM-1001 Message , [SYSM-1001], , FFDC, CRITICAL, , No memory. Probable Cause Indicates the switch has run out of system memory. Recommended Action Run the memShow command to view the switch memory usage. Restart or power cycle the switch. Run the supportFtp command to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
104 SYSM-1004 SYSM-1004 Message , [SYSM-1004], ,, ERROR, , Failed to retrieve current chassis configuration option, ret= Probable Cause Indicates there was a failure to read configuration data from the WWN card. Recommended Action Verify that the world wide name (WWN) card is present and operational and that the affected control processor (CP) is properly seated in its slot.
Chapter TAPE System Messages 105 TAPE-1001 Message , [TAPE-1001], , FFDC, INFO, , Key acquisition for . Probable Cause Indicates that the key acquisition for the pool or the container has begun or is complete. Recommended Action No action is required.
105 TAPE-1001 720 Fabric OS Message Reference 53-1002448-01
Chapter TRCE System Messages 106 TRCE-1001 Message Probable Cause , [TRCE-1001], ,, WARNING, , Trace dump available< optional slot indicating on which slot the dump occurs >! (reason: ) Indicates that trace dump files have been generated on the switch or the indicated slot.
106 TRCE-1003 TRCE-1003 Message , [TRCE-1003], ,, ERROR, , Trace dump was not transferred due to FTP error. Probable Cause Indicates that a trace dump has been created on the switch or the indicated slot but is not automatically transferred from the switch due to an FTP error, such as a wrong FTP address, FTP site down, or network down.
TRCE-1007 Recommended Action Severity 106 No action is required. INFO TRCE-1007 Message , [TRCE-1007], ,, INFO, , Notification of this CP has failed. Parameters temporarily out of sync with other CP. Probable Cause Indicates that the active CP is unable to alert the standby CP of a change in trace status. This message is only applicable to the Brocade 24000, and 48000. Recommended Action This message is often transitory.
106 TRCE-1010 TRCE-1010 Message , [TRCE-1010], ,, ERROR, , Traced fails to start Probable Cause Indicates that the trace daemon (traced), used for transferring trace files, failed to start. The trace capability within the switch is unaffected. The traced facility is normally restarted automatically by the system after a brief delay. Recommended Action If the message persists, restart the CP (dual-CP system) or restart the switch.
Chapter TRCK System Messages 107 TRCK-1001 Message , [TRCK-1001], ,, INFO, , Successful login by user . Probable Cause Indicates the track change feature has recorded a successful login. Recommended Action No action is required. Severity INFO TRCK-1002 Message , [TRCK-1002], ,, INFO, , Unsuccessful login by user after overall login failure attempts.
107 TRCK-1004 TRCK-1004 Message , [TRCK-1004], ,, INFO, , Config file change from task:. Probable Cause Indicates the track change feature recorded a configuration change for the switch. The track change feature records any change to the configuration file in nonvolatile memory, including a configDownload command. This message is not generated for a configUpload command.
Chapter TS System Messages 108 TS-1001 Message Probable Cause , [TS-1001], ,, WARNING, , NTP Query failed: . Indicates a network time protocol (NTP) query to the configured external clock server failed. Local clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric synchronization. This might be logged during temporary operational issues such as IP network connection issues to the external clock server.
108 TS-1006 TS-1006 Message Probable Cause , [TS-1006], ,, INFO, , . Indicates a time service event is occurring or has failed. The message might be one of the following: • Init failed. Time Service exiting Probable Cause: Initialization error, Time Server exits.
Chapter UCST System Messages 109 UCST-1003 Message , [UCST-1003], ,, INFO, , Duplicate Path to Domain , Output Port = , PDB pointer = 0x Probable Cause Indicates the duplicate paths were reported to the specified domain from the specified output port. The path database (PDB) pointer is the address of the path database and provides debugging information. Recommended Action No action is required.
109 UCST-1021 UCST-1021 Message , [UCST-1021], ,, INFO, , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required. Severity INFO UCST-1022 Message , [UCST-1022], ,, INFO, , In-order delivery option has been disabled.
UCST-1025 109 UCST-1025 Message , [UCST-1025], ,, INFO, , In-order delivery option has been enabled with Lossless-DLS option. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required. Severity INFO UCST-1026 Message , [UCST-1026], ,, INFO, , LossLess-DLS option has been enabled.
109 UCST-1027 732 Fabric OS Message Reference 53-1002448-01
Chapter UPTH System Messages 110 UPTH-1001 Message , [UPTH-1001], ,, WARNING, , No minimum cost path in candidate list. Probable Cause Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists in the candidate list (domain ID list). Recommended Action No action is required. This will end the current SPF computation.
110 UPTH-1002 734 Fabric OS Message Reference 53-1002448-01
Chapter VS System Messages 111 VS-1001 Message , [VS-1001], ,, INFO, , No virtual PWWN assignment for the device , port or (AG port ). Probable Cause Indicates that the device with virtual Port World Wide Name (PWWN) feature enabled, tried to login but there is no mapping for the device, port, or Access Gateway (AG) port. Recommended Action Execute the fapwwn command to map the device, port, or AG port.
111 VS-1004 VS-1004 Message , [VS-1004], ,, INFO, , Could not find Virtual PWWN config file for the switch. Probable Cause Indicates that the virtual Port World Wide Name (PWWN) feature has been enabled for the first time on the switch or the configuration file was corrupted or accidently removed. Recommended Action Creating a new default configuration file.
VS-1008 111 VS-1008 Message , [VS-1008], ,, INFO, , Virtualization services failed to create timer. Probable Cause Indicates failure in virtualization service daemon (vsd) start up because vsd has failed to create a timer. Recommended Action No action is required.
111 VS-1008 738 Fabric OS Message Reference 53-1002448-01
Chapter WEBD System Messages 112 WEBD-1001 Message , [WEBD-1001], ,, WARNING, , Missing or Invalid Certificate file -- HTTPS is configured but could not be started. Probable Cause Indicates the SSL certificate file is either invalid or absent. Recommended Action Install a valid key file.
112 WEBD-1006 Recommended Action Severity No action is required. WARNING WEBD-1006 Message , [WEBD-1006], ,, INFO, , HTTP server and weblinker restarted due to logfile truncation. Probable Cause Indicates the size of the HTTP log file exceeded the maximum limit. Recommended Action No action is required.
Chapter XTUN System Messages 113 XTUN-1000 Message , [XTUN-1000], ,, ERROR, , FCIP Tunnel Missed Data frame:I/T/L://. Probable Cause Indicates a missed frame with one or more FCP data information units during a SCSI write or read operation. Recommended Action If there was an unexpected job failure associated with this event, contact your customer support for assistance.
113 XTUN-1003 XTUN-1003 Message , [XTUN-1003], ,, ERROR, , FCIP Tunnel Message Transmission failed:I/T/L/E:///. Probable Cause Indicates a message transmission failure. Recommended Action If there was an unexpected job failure associated with this event, contact your customer support for assistance.
XTUN-1997 Recommended Action Severity 113 No action is required. INFO XTUN-1997 Message , [XTUN-1997], ,, WARNING, , FTRACE buffer on slot dp has been triggered. Probable Cause Indicates that a programmed trigger event has been detected. Recommended Action If there was an unexpected job failure associated with this event, contact your vendor's customer support for assistance.
113 XTUN-2001 Recommended Action Severity No action is required. INFO XTUN-2001 Message , [XTUN-2001], ,, ERROR, , FCIP Tunnel DOWN . Probable Cause Indicates that the specified tunnel has gone down. Recommended Action If the tunnel has not been administratively disabled or deleted, a possible network error or disruption has occurred.
XTUN-2005 Recommended Action Severity 113 No action is required. INFO XTUN-2005 Message , [XTUN-2005], ,, ERROR, , FCIP Tunnel Pri QoS DOWN . Probable Cause Indicates that the specified quality of service has gone down. This applies to the data classes only. If the f-class goes down, the tunnel itself is marked as down.
113 XTUN-2009 Recommended Action Severity No action is required. INFO XTUN-2009 Message , [XTUN-2009], ,, INFO, , IPsec: . Probable Cause Indicates that the status of an IPsec Security Association has changed. Recommended Action No action is required. Severity INFO XTUN-2010 Message , [XTUN-2010], ,, INFO, , SPD: . Probable Cause Indicates that the status of an SPD entry has changed.
XTUN-2021 Recommended Action Severity 113 No action is required. INFO XTUN-2021 Message , [XTUN-2021], ,, INFO, , FCIP Tunnel Circuit DELETED (). Probable Cause Indicates that the specified circuit has been administratively deleted. Recommended Action No action is required.
113 XTUN-2024 XTUN-2024 Message , [XTUN-2024], ,, INFO, , FCIP Tunnel Circuit MODIFIED (). Probable Cause Indicates that the attribute is modified. In most cases, the attribute value is modified within the specified circuit. Recommended Action No action is required.
Chapter ZEUS System Messages 114 ZEUS-1001 Message , [ZEUS-1001], ,, ERROR, , Port port fault. Please change the SFP or check cable. Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty cable between peer ports. Recommended Action Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have deteriorated and the Fibre Channel cable is faulty.
114 ZEUS-1004 ZEUS-1004 Message , [ZEUS-1004], , , ERROR, , S,C: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x. Probable Cause Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Action Restart the system at the next maintenance window. If the problem persists, replace the blade.
ZEUS-1016 Recommended Action Severity 114 Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, replace the blade.
114 ZEUS-1016 752 Fabric OS Message Reference 53-1002448-01
Chapter ZONE System Messages 115 ZONE-1002 Message , [ZONE-1002], ,, WARNING, , WWN zoneTypeCheck or zoneGroupCheck warning() at port(). Probable Cause Indicates that a zone filter or zone group check failure occurred. The frame filter logic reported a failure when creating or adding the zone groups during port login (PLOGI) trap processing.
115 ZONE-1005 Recommended Action Severity No action is required. INFO ZONE-1005 Message Probable Cause , [ZONE-1005], ,, INFO, , HARD and SOFT zones(, ) definitions overlap. Indicates that a port is zoned with mixed devices (WWN and D,I). During zoning database cross checking, either of the following is detected: • A port zone member is also listed as a member of a Mixed zone.
ZONE-1008 Recommended Action Severity 115 The following are the ways to avoid this problem: • Avoid having too many hosts zoned with a set of target devices at a single port. • Avoid having too many zones directed at a single port group on the switch. INFO ZONE-1008 Message , [ZONE-1008], ,, WARNING, , Port out of CAM entries.
115 ZONE-1013 ZONE-1013 Message , [ZONE-1013], ,, WARNING, , QuickLoop not supported. Probable Cause Indicates that the QuickLoop feature is not supported in the current version of Fabric OS. QuickLoop zones are not supported in Fabric OS version 4.x or later. Even if the QuickLoop zoning configuration is enabled on the switch, it will not be supported.
ZONE-1018 Recommended Action Severity 115 Edit the zone database to make sure that only one initiator is set for each FA zone configuration. ERROR ZONE-1018 Message Probable Cause , [ZONE-1018], ,, ERROR, , Incorrect zoning enforcement type() at port(). Indicates that an incorrect zoning enforcement type was reported on the specified port. This is a software error.
115 ZONE-1022 ZONE-1022 Message , [ZONE-1022], ,, INFO, , The effective configuration has changed to . Probable Cause Indicates that the effective zone configuration has changed to the specified zone name. Recommended Action Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-1027 115 ZONE-1027 Message , [ZONE-1027], ,, INFO, , Zoning transaction aborted . . Probable Cause Indicates the zoning transaction was aborted because of one of the following conditions: • • • • • • • • Zone Merge Received: The fabric is in the process of merging two zone databases. Zone Config update Received: The fabric is in the process of updating the zone database. Bad Zone Config: The new configuration is not viable.
115 ZONE-1030 Recommended Action Severity If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP transfers; then execute the supportSave command and contact your switch service provider. WARNING ZONE-1030 Message , [ZONE-1030], ,, WARNING, , Converting the zone db for PID format change failed. Probable Cause Indicates that the current zone database could not be converted to reflect the PID format change.
ZONE-1033 115 ZONE-1033 Message , [ZONE-1033], ,, ERROR, , Domain Lowest Max Zone DB size. Probable Cause Indicates that the specified domain has the lowest memory available for the zone database in the fabric. The zone database must be smaller than the memory available on this domain. Recommended Action Reduce the size of the zone database and retry the operation.
115 ZONE-1037 Recommended Action Severity Reduce the size of the zone database and retry the operation. ERROR ZONE-1037 Message , [ZONE-1037], ,, ERROR, , Unable to examine : error message . Probable Cause Indicates that the Fabric OS cannot examine the zone configuration file. Typically, the zone configuration is too large for the memory available on the switch.
ZONE-1040 115 ZONE-1040 Message , [ZONE-1040], ,, INFO, , Merged zone database exceeds limit. Probable Cause Indicates that the Fabric OS cannot read the merged zone configuration file. Typically, the zone configuration is too large for the memory available on the switch. Recommended Action Reduce the size of the zone database and retry the operation.
115 ZONE-1044 ZONE-1044 Message , [ZONE-1044], ,, INFO, , The Default Zone access mode is set to All Access. Probable Cause Indicates that the Default Zone access mode is set to All Access. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-1048 115 ZONE-1048 Message , [ZONE-1048], ,, WARNING, , ZONE ACA is rejected on the standby. Probable Cause Indicates that the standby zoning component did not receive a syncdump command from the primary side. Recommended Action Synchronize the standby control processor (CP) using the haSyncStart command.
115 ZONE-1052 ZONE-1052 Message , [ZONE-1052], ,, INFO, , The Interop Default Zone state is set to enabled. Probable Cause Indicates that the Interop Default Zone attribute state is enabled. Recommended Action Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-1056 115 ZONE-1056 Message , [ZONE-1056], ,, WARNING, , Non-ETIZ-Capable Switch (dom ) in fabric w/ETIZ Configured. Probable Cause Indicates that the cfgSave, cfgEnable, or cfgDisable commands will not work on the Fabric OS switch earlier than v6.4.0 in Interop Mode 2 (IM2) fabric when Enhanced/Overlapping TI zones (ETIZs) are configured. Recommended Action Remove Fabric OS switch earlier than v6.4.
115 ZONE-1059 ZONE-1059 Message , [ZONE-1059], ,, WARNING, , Unexpected TI routing behavior or a potentially unroutable TI configuration has been detected on local domain . Probable Cause Indicates that the current fabric topology and TI zone configuration may result in an unroutable condition or unexpected routing behavior.
Section II Audit Log Messages This section provides the Audit messages, including: • AUDIT AG System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT AN System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT AUTH System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • AUDIT BLS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
770 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT AG System Messages 116 AG-1033 Message AUDIT, , [AG-1033], INFO, CFG, , , , F_Port to N_Port mapping has been updated for N_Port (). Probable Cause Indicates that the F_Ports mapped to an N_Port have changed and the configuration file has been updated. Recommended Action No action is required.
116 AG-1036 AG-1036 Message AUDIT, , [AG-1036], WARNING, CFG, , , , Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended Action No action is required.
Chapter AUDIT AN System Messages 117 AN-1003 Message AUDIT, , [AN-1003], WARNING, FABRIC, , , , Latency bottleneck on port /. pct. of secs. affected. Avg. time b/w transmits us. Avg.
117 AN-1006 Recommended Action Severity No action is required. INFO AN-1006 Message AUDIT, , [AN-1006], INFO, FABRIC, , , , Bottleneck detection configuration is successfully changed. Probable Cause Indicates that the bottleneck detection configuration was changed by a user. Recommended Action No action is required.
AN-1012 117 AN-1012 Message AUDIT, , [AN-1012], WARNING, FABRIC, , , , Credits did not return from other end. Complete loss of credits on a VC on slot port . Probable Cause Indicates a credit loss. Recommended Action If this message is not followed by an AN-1013 message, please contact your vendor's customer support for assistance.
117 AN-1013 776 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT AUTH System Messages 118 AUTH-1045 Message AUDIT, , [AUTH-1045], ERROR, SECURITY, , , , Certificate not present in this switch in port . Probable Cause Indicates that the public key infrastructure (PKI) certificate is not installed in this switch. Recommended Action Check the certificate availability using the pkiShow command.
118 AUTH-3001 Run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR AUTH-3001 Message AUDIT, , [AUTH-3001], INFO, SECURITY, , , , Event: , Status: success, Info: type has been changed from [] to [].
AUTH-3004 118 AUTH-3004 Message AUDIT, , [AUTH-3004], INFO, SECURITY, , , , Event: , Status: failed, Info: Neighboring switch has a conflicting authentication policy; Port disabled. Probable Cause The specified E_Port was disabled because the neighboring switch rejected the authentication negotiation, and the local switch has a strict switch authentication policy.
118 AUTH-3007 If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider.
Chapter AUDIT BLS System Messages 119 BLS-1002 Message AUDIT, , [BLS-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an Internet Protocol Security (IPSec) or Internet Key Exchange (IKE) policy was added and the configuration file has been updated. Recommended Action No action is required.
119 BLS-1003 782 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT CCFG System Messages 120 CCFG-1002 Message AUDIT, , [CCFG-1002], INFO, CFG, , , , Started loading CEE system configuration. Probable Cause Indicates that the CEE system configuration has started loading. Recommended Action No action is required.
120 CCFG-1013 784 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT CNM System Messages 121 CNM-3001 Message AUDIT, , [CNM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: encryption group \\ created. Probable Cause Indicates an encryption group was created. Recommended Action No action is required.
121 CNM-3004 CNM-3004 Message AUDIT, , [CNM-3004], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Membernode \\ ejected from encryption group. Probable Cause Indicates a membernode was ejected from an encryption group. Recommended Action No action is required.
CNM-3008 Recommended Action Severity 121 No action is required. INFO CNM-3008 Message AUDIT, , [CNM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Routing mode of EE in slot set to . Probable Cause Indicates that the Encryption Engine (EE) routing mode was set. Recommended Action No action is required.
121 CNM-3011 CNM-3011 Message AUDIT, , [CNM-3011], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Encryption group synchronized. Probable Cause Indicates an encryption group was synchronized. Recommended Action No action is required.
Chapter AUDIT CONF System Messages 122 CONF-1000 Message AUDIT, , [CONF-1000], INFO, CFG, , , , configDownload completed successfully. . Probable Cause Indicates that the configDownload operation was initiated and completed successfully. The Info about the parameters and AD variable is the description of the classes of configuration parameters that were downloaded.
122 CONF-1042 CONF-1042 Message AUDIT, , [CONF-1042], INFO, CFG, , , , Fabric Configuration Parameter changed to . Probable Cause Indicates that the fabric configuration parameter value has been changed. Recommended Action No action is required.
Chapter AUDIT CVLM System Messages 123 CVLM-3001 Message AUDIT, , [CVLM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Failback mode set to . Probable Cause Indicates that the failback mode was set. Recommended Action No action is required.
123 CVLM-3004 CVLM-3004 Message AUDIT, , [CVLM-3004], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Cluster member added to HA cluster . Probable Cause Indicates a HA cluster member was added to an HA cluster. Recommended Action No action is required.
CVLM-3008 Recommended Action Severity 123 No action is required. INFO CVLM-3008 Message AUDIT, , [CVLM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Container \\ deleted. Probable Cause Indicates a cryptotarget container was deleted. Recommended Action No action is required.
123 CVLM-3011 CVLM-3011 Message AUDIT, , [CVLM-3011], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Initiator PWWN \\ Initiator NWWN \\ added to crypto target container \\. Probable Cause Indicates an initiator was added to a cryptotarget container. Recommended Action No action is required.
CVLM-3015 Recommended Action Severity 123 No action is required. INFO CVLM-3015 Message AUDIT, , [CVLM-3015], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Lun , attached through Initiator \\, removed from crypto target container \\. Probable Cause Indicates a LUN was removed from a cryptotarget container. Recommended Action No action is required.
123 CVLM-3018 CVLM-3018 Message AUDIT, , [CVLM-3018], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Tape pool \\ deleted. Probable Cause Indicates a tapepool was deleted. Recommended Action No action is required.
CVLM-3022 Recommended Action Severity 123 No action is required. INFO CVLM-3022 Message AUDIT, , [CVLM-3022], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Resume rekey of LUN attached through Initiator \\ in crypto tgt container \\. Probable Cause Indicates a resume rekey was performed. Recommended Action No action is required.
123 CVLM-3025 CVLM-3025 Message AUDIT, , [CVLM-3025], INFO, SECURITY, , , , Event: cryptocfg Status: started, Info: Decommission of device (container initiator , LUN ). Probable Cause Indicates that the decommission operation has started. Recommended Action No action is required.
CVLM-3028 Recommended Action Severity 123 No action is required.
123 CVLM-3028 800 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT ESS System Messages 124 ESS-1008 Message AUDIT, , [ESS-1008], INFO, FABRIC, , , , Fabric Name - configured (received from domain ). Probable Cause Indicates that the fabric name is configured or renamed. Recommended Action No action is required.
124 ESS-1010 802 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT FCIP System Messages 125 FCIP-1002 Message AUDIT, , [FCIP-1002], INFO, CFG, , , , An IPsec/IKE policy was added. Probable Cause Indicates that an IPsec/IKE policy was added and the config file was updated. Recommended Action No action is required.
125 FCIP-1003 804 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT FICU System Messages 126 FICU-1011 Message AUDIT, , [FICU-1011], INFO, CFG, , ,, FMS mode has been enabled. Probable Cause Indicates that FMS mode has been enabled. Recommended Action No action is required. Severity INFO FICU-1012 Message AUDIT, , [FICU-1012], INFO, CFG, , , , FMS mode has been disabled.
126 FICU-1020 FICU-1020 Message AUDIT, , [FICU-1020], INFO, CFG, , , , Port Addrs () have been Blocked by . Probable Cause Indicates that FMS has blocked the specified ports. Recommended Action No action is required.
Chapter AUDIT FW System Messages 127 FW-1202 Message AUDIT, , [FW-1202], WARNING, FW, , , , ,
127 FW-1404 FW-1404 Message AUDIT, , [FW-1404], WARNING, FW, , , ,
FW-3001 Recommended Action Severity 127 No action is required.
127 FW-3001 810 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT HTTP System Messages 128 HTTP-1002 Message AUDIT, , [HTTP-1002], INFO, ZONE, , , , Zoning transaction initiated by User: , Role: completed successfully. Probable Cause Indicates that the zoning database has been changed. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
128 HTTP-1003 812 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT IPAD System Messages 129 IPAD-1002 Message AUDIT, , [IPAD-1002], INFO, CFG, , , , Switchname has been successfully changed to . Probable Cause Indicates that a change with the switch name has occured. Recommended Action No action is required.
129 IPAD-1002 814 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT MS System Messages 130 MS-1027 Message AUDIT, , [MS-1027], INFO, FABRIC, , , , Fabric Name - configured. Probable Cause Indicates that the fabric name is configured or renamed. Recommended Action This is an informational message and does not require any action.
130 MS-1029 816 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT PMGR System Messages 131 PMGR-1001 Message AUDIT, , [PMGR-1001], INFO, LS, , , , Attempt to create switch succeeded. Probable Cause Indicates that the switch with the specified FID was successfully created. Recommended Action No action is required.
131 PMGR-1003 818 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT PORT System Messages 132 PORT-1006 Message AUDIT, , [PORT-1006], INFO, CFG, , , , Configuration changed for port (ID: ) in No_Module or No_Light state. Probable Cause Indicates the configuration changes were made to an offline port in No_Module or No_Light state. Recommended Action No action is required.
132 PORT-1009 PORT-1009 Message AUDIT, , [PORT-1009], INFO, CFG, , , , GigE Port (ID: ) has been disabled. Probable Cause Indicates a GigE port has been disabled. Recommended Action No action is required.
Chapter AUDIT RAS System Messages 133 RAS-2001 Message AUDIT, , [RAS-2001], INFO, SYSTEM, , , , , Audit message log is enabled. Probable Cause Indicates that the audit message log has been enabled. Recommended Action No action is required. Severity INFO RAS-2002 Message AUDIT, , [RAS-2002], INFO, SYSTEM, , , , Audit message log is disabled.
133 RAS-2003 822 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT SEC System Messages 134 SEC-1113 Message AUDIT, , [SEC-1113], WARNING, SECURITY, , , , [ license ] going to expire in days. Probable Cause Indicates the license period will expire soon. Recommended Action Get a new license for this feature.
134 SEC-3002 SEC-3002 Message Probable Cause AUDIT, , [SEC-3002], INFO, SECURITY, , , , Event: , Status: success, Info: . Indicates the specified security event has occurred. The Event Name can be one of the following: • • • • • Recommended Action Severity There has been an fabric configurations server (FCS) failover. A security policy has been activated. A security policy has been saved.
SEC-3005 134 SEC-3005 Message AUDIT, , [SEC-3005], INFO, SECURITY, , , , Event: , Status: success, Info: Added member(s) to policy . Probable Cause Indicates new members have been added to the specified security policy. If you use a wildcard (for example, an asterisk) in adding members to a policy, the audit report displays the wildcard in the event info field.
134 SEC-3008 SEC-3008 Message AUDIT, , [SEC-3008], INFO, SECURITY, , , , Event: , Status: success, Info: FCS member moved from position to . Probable Cause Indicates the fabric configuration server (FCS) list has been modified. One of the members of the list has been moved to a new position in the list, as identified in the message.
SEC-3012 Recommended Action Severity 134 Verify that the security statistic was intentionally reset. If the security statistic were intentionally reset, no action is required. If the security statistic was not intentionally reset, take appropriate action as defined by your enterprise security policy.
134 SEC-3015 SEC-3015 Message AUDIT, , [SEC-3015], INFO, SECURITY, , , , Event: , Status: success, Info: Moved server to position . Probable Cause Indicates a user has changed the position of the remote authentication dial-in user service (RADIUS or LDAP) server. Recommended Action Verify the RADIUS server position was intentionally changed.
SEC-3018 134 SEC-3018 Message AUDIT, , [SEC-3018], INFO, SECURITY, , , , Event: , Status: success, Info: Parameter [] changed from [] to []. Probable Cause Indicates the specified passwdCfg parameter is changed. Recommended Action Verify the passwdCfg parameter was intentionally changed. If the passwdCfg parameter was intentionally changed, no action is required.
134 SEC-3021 SEC-3021 Message AUDIT, , [SEC-3021], INFO, SECURITY, , , , Event: , Status: failed, Info: Failed login attempt via . Probable Cause Indicates a failed login attempt occurred. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
SEC-3025 Recommended Action Severity 134 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3025 Message AUDIT, , [SEC-3025], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] added.
134 SEC-3028 SEC-3028 Message AUDIT, , [SEC-3028], INFO, SECURITY, , , , Event: , Status: success, Info: User account [] deleted. Probable Cause Indicates the specified user account was deleted. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
SEC-3032 Recommended Action Severity 134 Verify the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO SEC-3032 Message AUDIT, , [SEC-3032], INFO, SECURITY, , , , Event: , Status: success, Info: Switch is configured to database.
134 SEC-3035 SEC-3035 Message AUDIT, , [SEC-3035], INFO, SECURITY, , , , Event: ipfilter, Status: success, Info: IP filter policy(ies) saved. Probable Cause Indicates the specified IP filter policies have been saved. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
SEC-3039 Recommended Action Severity 134 Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
134 SEC-3046 SEC-3046 Message AUDIT, , [SEC-3046], INFO, SECURITY, , , The FIPS Self Tests mode has been set to . Probable Cause Indicates there was a change in the FIPS Self Test mode. Recommended Action Verify the security event was planned. If the security event was planned, no action is required. If the security event was not planned, take appropriate action as defined by your enterprise security policy.
SEC-3050 Recommended Action Severity 134 No action is required. INFO SEC-3050 Message AUDIT, , [SEC-3050], INFO, SECURITY, Event: , Status: success, Info: . Probable Cause Indicates the specified sshutil operation was performed.. Recommended Action Verify the security event was planned. If the security event was planned, no action is required.
134 SEC-3063 Recommended Action Severity No action is required. INFO SEC-3063 Message AUDIT, , [SEC-3063], INFO, SECURITY, , , , Role ‘’ is copied from ‘’. Probable Cause Indicates that the specified role name has been copied from the source role. Recommended Action No action is required.
SEC-3066 134 SEC-3066 Message AUDIT, , [SEC-3066], INFO, SECURITY, , , , Configuration of user-defined roles is downloaded. Probable Cause Indicates the configuration of user-defined roles have been downloaded. Recommended Action No action is required.
134 SEC-4001 840 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT SNMP System Messages 135 SNMP-1004 Message AUDIT, , [SNMP-1004], ERROR, CFG, , , , Incorrect SNMP configuration. Probable Cause Indicates that the SNMP configuration is incorrect and therefore the SNMP service will not work correctly. Recommended Action Change the SNMP configuration to default using the snmpConfig --default command.
135 SNMP-1009 SNMP-1009 Message AUDIT, , [SNMP-1009], INFO, CFG, , , , Port traps are on port . Probable Cause Indicates the blocked or unblocked status of the port traps on the specified port. Recommended Action Execute the snmpTraps --show command to view the current status of the port.
Chapter AUDIT SPM System Messages 136 SPM-3001 Message AUDIT, , [SPM-3001], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Node initialized. Probable Cause Indicates a node was initialized. Recommended Action No action is required.
136 SPM-3004 SPM-3004 Message AUDIT, , [SPM-3004], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: EE in slot enabled. Probable Cause Indicates an encryption engine was enabled. Recommended Action No action is required.
SPM-3008 Recommended Action Severity 136 No action is required. INFO SPM-3008 Message AUDIT, , [SPM-3008], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: DH challenge generated for vault IP . Probable Cause Indicates a DH challenge was generated for a key vault. Recommended Action No action is required.
136 SPM-3011 SPM-3011 Message AUDIT, , [SPM-3011], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Local file \"\" deleted. Probable Cause Indicates a locally stored file was deleted. Recommended Action No action is required.
SPM-3015 Recommended Action Severity 136 No action is required. INFO SPM-3015 Message AUDIT, , [SPM-3015], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: Key vault type set to . Probable Cause Indicates the key vault type was set. Recommended Action No action is required.
136 SPM-3018 SPM-3018 Message AUDIT, , [SPM-3018], INFO, SECURITY, , ,, Event: cryptocfg Status: success, Info: master key recovered. Probable Cause Indicates a master key was recovered. Recommended Action No action is required.
SPM-3022 Recommended Action Severity 136 No action is required. INFO SPM-3022 Message AUDIT, , [SPM-3022], INFO, SECURITY, , ,,Event: cryptocfg Status: success, Info: Authentication card with certificate label \"\" deregistered. Probable Cause Indicates an authentication card was deregistered. Recommended Action No action is required.
136 SPM-3025 SPM-3025 Message AUDIT, , [SPM-3025], INFO, SECURITY, , , , Event: cryptocfg Status: success, Info: File imported via usb: Source: Destination: . Probable Cause Indicates a file was imported via USB device. Recommended Action No action is required.
SPM-3029 Recommended Action Severity 136 No action is required. INFO SPM-3029 Message AUDIT, , [SPM-3029], INFO, , , , Event: KeyVault Connection Status: , Info:KAC_Connect: . Probable Cause Indicates the status of key vault. Recommended Action No action is required.
136 SPM-3029 852 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT SULB System Messages 137 SULB-1001 Message AUDIT, , [SULB-1001], WARNING, FIRMWARE, , , , Firmwaredownload command has started. Probable Cause Indicates the firmwareDownload command has been started. This process should take approximately 17 minutes. The process is set to time out after 30 minutes. Recommended Action No action is required. Allow the firmwareDownload command to continue without disruption.
137 SULB-1004 SULB-1004 Message AUDIT, , [SULB-1004], INFO, FIRMWARE, , , , Firmwarecommit has completed. Probable Cause Indicates the FirmwareCommit command is executed. Recommended Action No action is required. Run the firmwareDownloadStatus command for more information.
SULB-1009 TABLE 10 Status messages and status codes (Continued) Status message Status code “firmwareCommit operation failed due to IPC error.” 0x55 "Unable to check the firmware version on Standby CP due to IPC error." 0x56 “Unable to restore the original firmware due to Standby CP timeout.” 0x57 "Standby CP failed to reboot and was not responding." 0x58 "Unable to check the firmware version on Standby CP due to IPC error.
137 SULB-1009 TABLE 10 856 Status messages and status codes (Continued) Status message Status code "The original firmware has been restored successfully on Standby CP." 0x7e "Unable to restore the original firmware on Standby CP." 0x7f "Standby CP reboots." 0x80 "Standby CP failed to reboot." 0x81 "Standby CP booted up with new firmware." 0x82 "Standby CP failed to boot up with new firmware." 0x83 “There was an unexpected reboot during firmwareDownload. The command is aborted.
SULB-1009 TABLE 10 137 Status messages and status codes (Continued) Status message Status code “firmwareRestore is entered. System will reboot and a firmwareCommit operation will start upon boot up.” 0xa8 "Switch is relocating the AP image." 0xa9 "The AP image is relocated successfully." 0xaa "Switch reboots during relocating the AP image. The operation will be restarted." 0xab “Blade failed to reboot with the original image. firmwareRestore command failed.
137 SULB-1009 TABLE 11 Error messages and error codes (Continued) Error message Error code "Our of disk space." 0x24 “Primary filesystem is inconsistent. Run firmwareRestore to restore the original firmware, or contact your service provider for recovery.” 0x25 "The post-install script failed." 0x26 "Unexpected reboot." 0x27 "Primary kernel partition is inconsistent. Please contact your service provider for recovery." 0x28 "The pre-install script failed.
SULB-1009 137 0x29 - The pre-install script failed. This error may be caused by an unsupported blade type in the chassis. Remove or power off the unsupported blades before proceeding. Another possible cause may be an invalid chassisConfig option setting. In that case, reset the chassisConfig option before retrying firmwareDownload. 0x2e - Invalid Red Hat package manager (RPM) package. This error maybe caused by an inconsistent firmware image loaded on the file server.
137 SULB-1010 In a director-class switch, when firmwareDownload fails, the two CPs may end up with different versions of firmware and they may not gain high-availability (HA) sync. In that case, run firmwareDownload single mode (-s) to upgrade the firmware on the standby CP to the same version as the active CP. Then retry firmwareDownload to download the desired version of firmware onto the CPs. Refer to the Fabric OS Administrator’s Guide for troubleshooting information.
SULB-1020 Recommended Action Severity 137 Run the slotShow command. If the blade is in a FAULTY state, run the slotPowerOff and slotPowerOn commands to trigger another firmwareDownload. If the blade is stuck in LOADING state, remove and re-insert the blade to trigger another firmwareDownload. If the problem persists, contact your switch service provider.
137 SULB-1024 Recommended Action Severity The firmwareCommit command will be started automatically after the blade boots up to repair the secondary partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider.
SULB-1031 Recommended Action Severity 137 The firmwareDownload command will continue after the switch has rebooted. Run the firmwareDownloadStatus command to monitor progress. If the problem persists, contact your switch service provider. WARNING SULB-1031 Message AUDIT, , [SULB-1031], WARNING, FIRMWARE, , , , The switch is relocating an internal firmware image.
137 SULB-1034 SULB-1034 Message AUDIT, , [SULB-1034], ERROR, FIRMWARE, , , Relocation of internal image timed out. Probable Cause Indicates there may be an error caused by a switch initialization issue after the internal image is relocated. It may also be caused by an internal Ethernet issue or by persistent storage failure. Recommended Action Reboot the switch. This will cause the internal image to be relocated again.
SULB-1038 137 SULB-1038 Message AUDIT, , [SULB-1038], WARNING, FIRMWARE, Co-CPU has not booted up properly. Skip the firmwaredownload command on the co-CPU. Probable Cause Indicates that the Main CPU cannot access the co-CPU to update the firmware on the co-CPU or run any other firmwaredownload command on the co-CPU. If firmwareDownload in progress it will continue without updating the co-CPU firmware.
137 SULB-1041 SULB-1041 Message AUDIT, , [SULB-1041], INFO, FIRMWARE, , , , Firmware has been activated successfully on standby CP. Probable Cause Indicates the firmwareActivate command has completed successfully on standby CP. Recommended Action No action is required. The firmwareActivate command has completed on standby CP as expected. Severity Run the firmwareShow command to verify the firmware versions.
Chapter AUDIT SWCH System Messages 138 SWCH-1012 Message AUDIT, , [SWCH-1012], INFO, CFG, , , , Trunk Area () has been enabled for one or more ports. Probable Cause Indicates that a Trunk Area has been enabled for one or more ports and the config file has been updated. Recommended Action No action is required.
138 SWCH-1014 868 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT UCST System Messages 139 UCST-1021 Message AUDIT, , [UCST-1021], INFO, CFG, , , , In-order delivery option has been enabled. Probable Cause Indicates the IOD option has been enabled for the switch. This option guarantees in-order delivery of frames during topology changes. Recommended Action No action is required.
139 UCST-1024 UCST-1024 Message AUDIT, , [UCST-1024], INFO, CFG, , , , Dynamic Load Sharing option has been disabled. Probable Cause Indicates the DLS option has been disabled for the switch. Recommended Action No action is required.
UCST-1027 Recommended Action Severity 139 No action is required.
139 UCST-1027 872 Fabric OS Message Reference 53-1002448-01
Chapter AUDIT ZONE System Messages 140 ZONE-3001 Message Probable Cause AUDIT, , [ZONE-3001], INFO, ZONE, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates that a new zone object member or members have been added to the specified zone object set.
140 ZONE-3004 The zone object type variable can be alias, zone member, zone, or zone configuration. Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy.
ZONE-3007 140 ZONE-3007 Message AUDIT, , [ZONE-3007], INFO, ZONE, , , , Event: , Status: success, Info: Zone configuration \"\" enabled. . Probable Cause Indicates that the specified zone configuration has been enabled. Recommended Action Verify that the event was planned. If the event was planned, no action is required.
140 ZONE-3011 Recommended Action Severity Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3011 Message AUDIT, , [ZONE-3011], INFO, ZONE, , , , Event: , Status: success, Info: Zone object \"\" expunged.
ZONE-3014 140 ZONE-3014 Message Probable Cause AUDIT, , [ZONE-3014], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" added to \"\". Indicates that the specified new AD object member or members have been added to the specified AD object set. The AD object set type variable can be an AD alias or AD member. The string “...
140 ZONE-3017 ZONE-3017 Message Probable Cause AUDIT, , [ZONE-3017], INFO, FABRIC, , , , Event: , Status: success, Info: \"\" created with \"\". Indicates that the specified AD has been created. The AD object set type variable can be an AD alias or AD member. The string “...
ZONE-3021 Recommended Action Severity 140 Verify that the event was planned. If the event was planned, no action is required. If the event was not planned, take appropriate action as defined by your enterprise security policy. INFO ZONE-3021 Message AUDIT, , [ZONE-3021], INFO, FABRIC, , , , Event: , Status: success, Info: AD object \"\" renamed to \"\".
140 ZONE-3024 ZONE-3024 Message AUDIT, , [ZONE-3024], INFO, FABRIC, , , , Command: , Status: success, Info: executed. . Probable Cause Indicates that the ad --transabort command has completed successfully in the specified AD. Recommended Action Verify that the event was planned. If the event was planned, no action is required.