53-1001360-01 28 July 2009 DCFM Installation, Migration, and Transition Guide Supporting DCFM 10.3.
Copyright © 2006-2009 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
Contents About This Document In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . x What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Professional Plus trial installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Professional Plus trial requirements. . . . . . . . . . . . . . . . . . . . . . 19 Installing Professional Plus trial on Windows systems . . . . . . . 19 Professional Plus trial pre-installation requirements on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Installing Professional Plus trial on UNIX systems. . . . . . . . . . .
Contents Chapter 2 Migration In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Professional edition migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Professional edition pre-migration requirements on Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Migrating from Professional edition 10.0.X to Professional edition 10.3.X on Windows systems. . . . . . . . . . . . . . . .
Contents Professional Plus edition migration . . . . . . . . . . . . . . . . . . . . . . . . . 147 Upgrading Professional Plus edition to Enterprise edition . . . 147 Professional Plus edition pre-migration requirements on Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 Migrating from Professional Plus edition to Enterprise edition on Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents Chapter 3 Transition In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 EFCM transition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219 Toolbar differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221 EFCM to DCFM command mapping . . . . . . . . . . . . . . . . . . . . .222 Fabric Manager transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents viii DCFM Installation, Migration, and Transition Guide 53-1001360-01
About This Document In this chapter • How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix • Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x • What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii • Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii • Notice to the reader . . . . . . . . . . . .
About This Document Supported hardware and software In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for DCFM 10.3.X, documenting all possible configurations and scenarios is beyond the scope of this document.
About This Document TABLE 1 Supported Hardware Device Name Terminology used in documentation Brocade AP7600 switch6 4 Gbps 32-port Switch Switch11 8 Gbps 16-FC ports, 6-Gbit ports Extension Switch 10 Brocade 8000 switch 8 Gbps 16-FC-ports, 10 GbE8-Ethernet Port Switch Brocade 415 Host Bus Adapter 4 Gbps 1-port HBA Brocade 425 Host Bus Adapter 4 Gbps 2-port HBA Brocade 815 Host Bus Adapter 8 Gbps 1-port HBA Brocade 825 Host Bus Adapter 8 Gbps 2-port HBA Brocade 7800 Brocade 48000 directo
About This Document TABLE 1 Supported Hardware Device Name Terminology used in documentation FCoE10-24 Blade 10 Gig FCoE port Blade FX8-24 Blade12, 13 M4700F Fabric Switch 8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports Extension Blade 12 32-Port, 4 Gbps Switch M6140 Director12 140-Port Director Mi10K Director12 256-Port Director 1 Platform requires Fabric OS v5.1.0 or later 2 Platform requires Fabric OS v5.2.0 or later 3 Platform requires Fabric OS v5.2.
About This Document Document conventions This section describes text formatting conventions and important notice formats used in this document.
About This Document Notice to the reader This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations. These references are made for informational purposes only. Corporation Referenced Trademarks and Products Linus Torvalds Linux Microsoft Corporation Windows, Windows NT, Internet Explorer Netscape Communications Corporation Netscape Red Hat, Inc.
About This Document Other industry resources For additional resource information, visit the Technical Committee T11 Web site. This Web site provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications: http://www.t11.org For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site: http://www.fibrechannel.
About This Document • Brocade 48000—Inside the chassis next to the power supply bays • Brocade DCX—On the bottom right on the port side of the chassis • Brocade DCX-4S—On the bottom right on the port side of the chassis, directly above the cable management comb. 4. World Wide Name (WWN) Use the wwn command to display the switch WWN. If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX.
Chapter 1 Installation In this chapter • Headless installation information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 • Professional, Professional Plus, and Enterprise edition feature support . . . 2 • Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 • Professional edition installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 • Professional Plus trial installation . . . . . . . .
1 Professional, Professional Plus, and Enterprise edition feature support Professional, Professional Plus, and Enterprise edition feature support The following table details whether the features are supported in Professional edition, Professional Plus, or Enterprise edition, or only through the device’s Element Manager.
Professional, Professional Plus, and Enterprise edition feature support TABLE 2 1 Features supported Feature Description Professional Edition Professional Plus Edition Firmware Management and Supportsave Firmware download Yes Yes Yes Capture Supportsave Yes Yes Yes HBA Server/Storage port mapping HBA Server/Storage port mapping No Yes Yes High Integrity Fabric High Integrity Fabric No Yes Yes IPv6 Server - Client support Server - Server support Server - Switch support Yes Yes
1 Professional, Professional Plus, and Enterprise edition feature support TABLE 2 Features supported Feature Description Professional Edition Professional Plus Edition Port Fencing Port Fencing policy configuration for M-EOS switches No Yes Yes RBAC User management No Yes Yes Reports Generate Yes Yes Yes View Yes Yes Yes Performance data report No Yes Yes FCR Reports No Yes Yes Up to 1000 port support Yes Yes Yes Up to 2560 port support No Yes Yes Up to 9000 port s
Requirements 1 Requirements Use the following to determine if you have met the requirements for this application. Operating system requirements The following table summarizes the minimum recommended Host requirements for running DCFM.
1 Memory requirements TABLE 3 System Requirements Enterprise Professional Plus Professional Operating System Version Installation Type Small Medium Large Solaris Solaris 10 Server Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4 Core 1.2 GHz UltraSPARC T2 or T2 Plus or equivalent Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4/6/8 Core 1.
Disc space requirements 1 Disc space requirements The following table summarizes the minimum recommended disc space requirements for running DCFM on for Windows, Linux and Solaris systems. TABLE 5 Disc Space Requirements Server/Client Enterprise Small Medium Large Professional Professional Plus Server plus 1 local client 7GB 7 GB 40 GB 2.
1 Scalability requirements Scalability requirements The following tables summarize the scalability limits for support with DCFM. TABLE 6 Small Medium Large Number of Fabrics 8 16 24 Number of Domains 20 60 120 Number of Switch Ports 2000 5000 9000 Number of Device Ports 5000 10000 20000 Number of Access Gateways 20 30 40 PM Polling 5 min. 5 min. 10 min.
Professional edition installation TABLE 9 1 Supported Limits by SAN size for mixed fabrics (Fabric OS and M-EOS fabrics in NI mode) Values Small Medium Large Number of Fabrics 4 8 12 Number of Domains 10 30 60 Number of Switch Ports 1000 2500 5000 Number of Device Ports 2500 5000 10000 Number of Access Gateways 20 30 40 PM Polling 5 min. 5 min. 10 min. Professional edition installation Use the following table to install Professional edition 10.3.X.
1 Installing Professional edition on Windows systems 2. Click Next on the Introduction screen. 3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next. 4. Select the usual location for your system’s application files (for example, D:\Program Files\DCFM Pro 10.3.X) on the Select Install Folder screen and click Next. Do not install to the root directory (for example, C:\). 5.
Installing Professional edition on Windows systems 1 10. Complete the following steps on the Server IP Configuration screen. FIGURE 2 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional edition on Windows systems 11. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 3 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional edition pre-installation requirements on UNIX systems 1 14. Enter your user name and password. The defaults are Administrator and password, respectively. 15. Click Login. 16. Click OK on the Login Banner. Professional edition pre-installation requirements on UNIX systems • To avoid errors, close all instances of the application before beginning the installation or uninstallation procedures.
1 Installing Professional edition on UNIX systems Installing Professional edition on UNIX systems 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFMPro\\install.bin 2. Click Next on the Introduction screen. 3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next. 4.
Installing Professional edition on UNIX systems 1 10. Complete the following steps on the Server IP Configuration screen. FIGURE 5 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional edition on UNIX systems 11. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 6 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional edition pre-installation requirements on UNIX systems (headless) 1 14. Enter your user name and password. The defaults are Administrator and password, respectively. 15. Click Login. 16. Click OK on the Login Banner. Professional edition pre-installation requirements on UNIX systems (headless) An X Server display is required, even when performing a headless installation, to run the initial configuration.
1 Installing Professional edition on UNIX systems (headless) Installing Professional edition on UNIX systems (headless) To perform a headless installation through the CLI, complete the following steps. 1. Insert the installation DVD into the DVD-ROM drive and open the following file. install.exe -i silent -DUSER_INSTALL_DIR="D:\Program Files\DCFM 10.3.0" The installation starts in CLI mode. 2. Read the license agreement, type Y and press Enter. 3.
Professional Plus trial installation 1 Professional Plus trial installation Operating System Installation Procedures Windows systems To install Enterprise trial, review the following section: “Professional Plus trial requirements” on page 19 “Installing Professional Plus trial on Windows systems” on page 19 “Installing the ODBC driver” on page 59 “Configuring an explicit server IP address” on page 60 • • • • UNIX systems To install Enterprise trial, review the following sections: “Professional Plus
1 Installing Professional Plus trial on Windows systems 4. Select the usual location for your system’s application files (for example, D:\Program Files\DCFM 10.3.X) on the Select Install Folder screen and click Next. Do not install to the root directory (for example, C:\). 5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install. 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7.
Installing Professional Plus trial on Windows systems 1 12. Complete the following steps on the Server IP Configuration screen. FIGURE 8 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional Plus trial on Windows systems 13. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 9 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional Plus trial pre-installation requirements on UNIX systems 1 17. Enter your user name and password. The defaults are Administrator and password, respectively. 18. Click Login. 19. Click OK on the Login Banner. Professional Plus trial pre-installation requirements on UNIX systems • To avoid errors, close all instances of the application before beginning the installation or uninstallation procedures.
1 Installing Professional Plus trial on UNIX systems Installing Professional Plus trial on UNIX systems 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFM\\install.bin 2. Click Next on the Introduction screen. 3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next. 4.
Installing Professional Plus trial on UNIX systems 1 12. Complete the following steps on the Server IP Configuration screen. FIGURE 11 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional Plus trial on UNIX systems 13. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 12 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional Plus trial pre-installation requirements on UNIX systems (headless) 1 17. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your user name and password do not change. 18. Click Login. 19. Click OK on the Login Banner. Professional Plus trial pre-installation requirements on UNIX systems (headless) An X Server display is required, even when performing a headless installation, to run the initial configuration.
1 Installing Professional Plus trial on UNIX systems (headless) Installing Professional Plus trial on UNIX systems (headless) To perform a headless installation through the CLI, complete the following steps. 1. Insert the installation DVD into the DVD-ROM drive and open the following file. install.exe -i silent -DUSER_INSTALL_DIR="D:\Program Files\DCFM 10.3.0" The installation starts in CLI mode. 2. Read the license agreement, type Y and press Enter. 3.
Professional Plus edition installation 1 Professional Plus edition installation Operating System Installation Procedures Windows systems To install Professional Plus edition, review the following sections: “Installing Enterprise edition on Windows systems” on page 49 “Installing the ODBC driver” on page 59 “Configuring an explicit server IP address” on page 60 • • • UNIX systems To install Professional Plus edition, review the following sections: “Enterprise edition pre-installation requirements on
1 Installing Professional Plus edition on Windows systems 9. Enter the serial number (on the DVD jewel case) and license key (on the Key Certificate) on the Server License screen and click Next. The License Key field is not case-sensitive. 10. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. If port 21 is busy, a message displays. Click OK to close the message and continue.
Installing Professional Plus edition on Windows systems 1 11. Complete the following steps on the Server IP Configuration screen. FIGURE 14 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional Plus edition on Windows systems 12. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 15 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional Plus edition pre-installation requirements on UNIX systems 1 16. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your user name and password do not change. 17. Click Login. 18. Click OK on the Login Banner. Professional Plus edition pre-installation requirements on UNIX systems • To avoid errors, close all instances of the application before beginning the installation or uninstallation procedures.
1 Installing Professional Plus edition on UNIX systems Installing Professional Plus edition on UNIX systems 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFM\\install.bin 2. Click Next on the Introduction screen. 3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next. 4.
Installing Professional Plus edition on UNIX systems 1 11. Complete the following steps on the Server IP Configuration screen. FIGURE 17 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Professional Plus edition on UNIX systems 12. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 18 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional Plus edition pre-installation requirements on UNIX systems (headless) 1 15. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your user name and password do not change. 16. Click Login. 17. Click OK on the Login Banner.
1 Installing Professional Plus edition on UNIX systems (headless) Installing Professional Plus edition on UNIX systems (headless) To perform a headless installation through the CLI, complete the following steps. 1. Insert the installation DVD into the DVD ROM drive and open the following file. install.exe -i silent -DUSER_INSTALL_DIR="D:\Program Files\DCFM 10.3.0" The installation starts in CLI mode. 2. Read the license agreement, type Y and press Enter. 3.
Enterprise trial installation 1 Enterprise trial installation Operating System Installation Procedures Windows systems To install Enterprise trial, review the following sections: “Enterprise trial requirements” on page 39 “Installing Enterprise trial on Windows systems” on page 39 “Installing the ODBC driver” on page 59 “Configuring an explicit server IP address” on page 60 • • • • UNIX systems To install Enterprise trial, review the following sections: “Enterprise trial requirements” on page 39 “En
1 Installing Enterprise trial on Windows systems 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7. Click Next on the Welcome screen. 8. Select No on the Copy Data and Settings screen and then click Next. To migrate data from a previous management application version, refer to Chapter 2, “Migration”. 9. Click Next on the Server License screen. 10. Select Enterprise on the Trial Editions screen and click Next. 11.
Installing Enterprise trial on Windows systems 1 12. Complete the following steps on the Server IP Configuration screen. FIGURE 20 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Enterprise trial on Windows systems 13. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 21 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise trial pre-installation requirements on UNIX systems 1 17. Select the Start DCFM Client check box on the Start Server screen. 18. Click Finish. After all of the selected services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively. 20. Click Login. 21. Click OK on the Login Banner.
1 Installing Enterprise trial on UNIX systems Installing Enterprise trial on UNIX systems 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFM\\install.bin 2. Click Next on the Introduction screen. 3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next. 4.
Installing Enterprise trial on UNIX systems 1 12. Complete the following steps on the Server IP Configuration screen. FIGURE 23 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Enterprise trial on UNIX systems 13. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 24 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise trial pre-installation requirements on UNIX systems (headless) 1 17. Select the Start DCFM Client check box on the Start Server screen. 18. Click Finish. After all of the selected services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively. 20. Click Login. 21. Click OK on the Login Banner.
1 Installing Enterprise trial on UNIX systems (headless) Installing Enterprise trial on UNIX systems (headless) To perform a headless installation through the CLI, complete the following steps. 1. Insert the installation DVD into the DVD-ROM drive and open the following file. install.exe -i silent -DUSER_INSTALL_DIR="D:\Program Files\DCFM 10.1.0" The installation starts in CLI mode. 2. Read the license agreement, type Y and press Enter. 3. Type the installation folder path and press Enter, if necessary.
Enterprise edition installation 1 Enterprise edition installation Operating System Installation Procedures Windows systems To install Enterprise edition, review the following sections: “Installing Enterprise edition on Windows systems” on page 49 “Installing the ODBC driver” on page 59 “Configuring an explicit server IP address” on page 60 • • • UNIX systems To install Enterprise edition, review the following sections: “Enterprise edition pre-installation requirements on UNIX systems” on page 53 “In
1 Installing Enterprise edition on Windows systems 9. Enter the serial number (on the DVD jewel case) and license key (on the Key Certificate) on the Server License screen and click Next. The License Key field is not case-sensitive. 10. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. If port 21 is busy, a message displays. Click OK to close the message and continue.
Installing Enterprise edition on Windows systems 1 11. Complete the following steps on the Server IP Configuration screen. FIGURE 26 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
1 Installing Enterprise edition on Windows systems 12. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 27 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise edition pre-installation requirements on UNIX systems 1 15. Verify your configuration and license information on the Server License Summary screen and click Next. 16. Select the Start DCFM Client check box on the Start Server screen. 17. Click Finish. After all of the selected services are started, the Log In dialog box displays. 18. Enter your user name and password. The defaults are Administrator and password, respectively. 19. Click Login. 20. Click OK on the Login Banner.
1 Installing Enterprise edition on UNIX systems • Make sure you test the DISPLAY definition by running the command xterm from the same shell from which you run install.bin. A new X terminal window to the destination X Server display should open. Installing Enterprise edition on UNIX systems 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFM\\install.bin 2. Click Next on the Introduction screen. 3.
Installing Enterprise edition on UNIX systems 1 10. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service. NOTE If you use an FTP Server which is not configured on the same machine as DCFM, the Firmware Repository feature will not be available.
1 Installing Enterprise edition on UNIX systems 11. Complete the following steps on the Server IP Configuration screen. FIGURE 29 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
Installing Enterprise edition on UNIX systems 1 12. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. 24600 FIGURE 30 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
1 Enterprise edition pre-installation requirements on UNIX systems (headless) 15. Verify your configuration and license information on the Server License Summary screen and click Next. 16. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 17. Enter your user name and password. The defaults are Administrator and password, respectively. 18. Click Login. 19. Click OK on the Login Banner.
Installing Enterprise edition on UNIX systems (headless) 1 Installing Enterprise edition on UNIX systems (headless) To perform a headless installation through the CLI, complete the following steps. 1. Insert the installation DVD into the DVD ROM drive and open the following file. install.exe -i silent -DUSER_INSTALL_DIR="D:\Program Files\DCFM 10.3.0" The installation starts in CLI mode. 2. Read the license agreement, type Y and press Enter. 3.
1 Configuring an explicit server IP address Configuring an explicit server IP address If you select a specific IP address from the Server IP Configuration screen and the selected IP address changes, you will not be able to connect to the server. To change the IP address, complete the following steps. 1. Open the DCFMsvc.conf file (\conf\DCFMsvc.conf) in a text editor (such as Notepad. 2. Enter the new server IP address in the bind address variable as follows: set.
Smart Card driver installation 1 4. If you installed a pcsc directory into different location than /opt, modify the pcscctl script to change “/opt” to the directory you specified in step 1. > cd > vi pcscctl Search for “/opt” and change it to the name of the new directory. 5. Create a soft link into the system directory. This is to support the automatic restart of the pcscd daemon upon system restart. If you installed the pcsc directory into the /opt directory, just create the soft link.
1 Smart Card driver installation Installing the Smart Card driver on the remote client 1. Complete steps 1-4 in “Installing the Smart Card driver on the local client” on page 60. 2. Run the following commands in order to support remote clients (Web Start). > cd /usr/lib > ln –s /opt/pcsc/lib/libpcsclite.so . NOTE If a soft link exists on libpcsclite.so, you must ensure that the final file is linked to /opt/pcsc/lib/libpcsclite.so.xxx. You can back up the original one first. See the example below.
Smart Card driver installation 1 3. If there is an existing pcscd script in this directory, you can move and rename this file before you overwrite it. > mv /etc/init.d/pcscd /etc/init.d/pcscd.org 4. Create a soft link using the following command. > ln –s /opt/pcsc/pcscctl /etc/init.d/pcscd The existing pcscd.org script in this directory implies that a different driver version exists. You can compare the existing one with the one under /opt/pcsc/pcscd/sbin.
1 Uninstall Uninstall This section provides step-by-step instructions to uninstall the application from both Windows and UNIX systems. NOTE The Management application is installed on a separate directory from your previous version; therefore, you do not have to uninstall the previous version immediately. However, you cannot run both versions simultaneously. Uninstalling from Windows systems Follow these instructions to uninstall the application from your Windows system. 1.
Uninstalling from UNIX systems (headless) 1 Uninstalling from UNIX systems (headless) If the application was installed using the headless installation, complete the following steps to uninstall. 1. Go to /Uninstall_DCFM10.X.X. 2. Choose one of the following options: • To fully uninstall DCFM (configuration and performance data is retained to be re-used by the new installation), execute \Uninstall_DCFM 10.X.X.exe –f .
1 66 Uninstalling from UNIX systems (headless) DCFM Installation, Migration, and Transition Guide 53-1001360-01
Chapter 2 Migration In this chapter • Professional edition migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 • Professional Plus trial migration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 • Professional Plus edition migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 • Enterprise trial migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 • Enterprise edition migration . . . . . .
2 TABLE 11 Professional edition migration Migration Paths Current Software Release To Software Release Professional edition 10.0.X Windows systems Professional Plus edition 10.3.X To migrate from Professional edition 10.0.X to Professional Plus edition 10.3.X, review the following sections: • “Professional edition pre-migration requirements on Windows systems” on page 72 • “Migrating from Professional edition 10.0.X to Professional edition 10.3.
Professional edition migration TABLE 11 2 Migration Paths Current Software Release To Software Release Migration Procedures Professional edition 10.0.X on UNIX systems Enterprise trial 10.3.X To migrate from Professional edition 10.0.X to Enterprise trial 10.3.X, review the following sections: • “Professional edition pre-migration requirements on UNIX systems” on page 76 • “Migrating from Professional edition 10.0.X to Professional edition 10.3.
2 TABLE 11 Professional edition migration Migration Paths Current Software Release To Software Release Migration Procedures Professional edition 10.1.X Windows systems Enterprise edition 10.3.X To migrate from Professional edition 10.1.X to Enterprise edition 10.3.X, review the following sections: • “Professional edition pre-migration requirements on Windows systems” on page 72 • “Migrating from Professional edition 10.1.X to Professional edition 10.3.
Professional edition migration TABLE 11 2 Migration Paths Current Software Release To Software Release Migration Procedures Professional edition 10.3.X Windows systems Professional Plus trial 10.3.X To migrate from Professional edition 10.3.X to Professional Plus trial 10.3.X, review the following sections: • “Professional edition pre-migration requirements on Windows systems” on page 72 • “Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.
2 Professional edition pre-migration requirements on Windows systems Professional edition pre-migration requirements on Windows systems Before you migrate from Professional, complete the following: • Make sure that you fully back up your current Management application data on your management server. • Make sure you close all instances of the application before upgrading. Migrating from Professional edition 10.0.X to Professional edition 10.3.
Migrating from Professional edition 10.0.X to Professional edition 10.3.X on Windows systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software.
2 Migrating from Professional edition 10.0.X to Professional edition 10.3.X on Windows systems 13. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 31 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.0.X to Professional edition 10.3.X on Windows systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 32 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Professional edition pre-migration requirements on UNIX systems 17. Click Finish. After all of the DCFM services are started, the Log In dialog box displays. 18. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 19. Click Login. 20. Click OK on the Login Banner.
Migrating from Professional edition 10.0.X to Professional edition 10.3.X on UNIX systems 2 Migrating from Professional edition 10.0.X to Professional edition 10.3.X on UNIX systems Use the following procedure to migrate from Professional edition 10.0.X software to Professional edition 10.3.X software on a UNIX management server. NOTE Migration of FC port performance statistics is only supported only from DCFM 10.1.4 to 10.3.0. It is not supported from 10.0.x to 10.3.0 or 10.1.1, 10.1.2, and 10.1.
2 Migrating from Professional edition 10.0.X to Professional edition 10.3.X on UNIX systems 10. Click Start on the Data Migration screen. Data migration may take up to 30 minutes. When data migration is complete, the previous version is partially uninstalled. 11. Click Next on the Data Migration screen. 12. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. The default selection reflects the previous Professional edition configuration.
Migrating from Professional edition 10.0.X to Professional edition 10.3.X on UNIX systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 34 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.1.X to Professional edition 10.3.X on Windows systems 18. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 19. Click Login. 20. Click OK on the Login Banner. Migrating from Professional edition 10.1.X to Professional edition 10.3.X on Windows systems NOTE Remote migration is not supported for Professional edition.
Migrating from Professional edition 10.1.X to Professional edition 10.3.X on Windows systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software.
2 Migrating from Professional edition 10.1.X to Professional edition 10.3.X on Windows systems 13. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 35 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.1.X to Professional edition 10.3.X on Windows systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 36 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.1.X to Professional edition 10.3.X on UNIX systems 17. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 18. Click Login. 19. Click OK on the Login Banner. Migrating from Professional edition 10.1.X to Professional edition 10.3.X on UNIX systems NOTE Migration of FC port performance statistics is only supported only from DCFM 10.1.4 to 10.
Migrating from Professional edition 10.1.X to Professional edition 10.3.X on UNIX systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software.
2 Migrating from Professional edition 10.1.X to Professional edition 10.3.X on UNIX systems 13. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 37 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.1.X to Professional edition 10.3.X on UNIX systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server. FIGURE 38 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on Windows systems 17. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 18. Click Login. 19. Click OK on the Login Banner. Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.
Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on Windows systems 2 8. Choose one of the following options to migrate data from a previous version. To migrate data from a previous management application, you must do so now. • To migrate data from the previous version installed (automatically detected), select Yes, from DCFM in the following location.
2 Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on Windows systems 16. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 39 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on Windows systems 2 17. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 40 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on UNIX systems 21. Select the Start DCFM Client check box, if necessary, on the Start Server screen and click Finish. After all of the selected services are started, the Log In dialog box displays. 22. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 23. Click Login. 24. Click OK on the Login Banner.
Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on UNIX systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10.
2 Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on UNIX systems 15. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 41 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Professional Plus trial 10.3.X on UNIX systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 42 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on Windows systems 21. Click Finish. After all of the selected services are started, the Log In dialog box displays. 22. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 23. Click Login. 24. Click OK on the Login Banner. Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.
Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on Windows systems 2 8. Choose one of the following options to migrate data from a previous version. To migrate data from a previous management application, you must do so now. • To migrate data from the previous version installed (automatically detected), select Yes, from DCFM in the following location.
2 Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on Windows systems 15. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 43 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on Windows systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 44 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device.
2 Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on UNIX systems 20. Select the Start DCFM Client check box, if necessary, on the Start Server screen and click Finish. After all of the selected services are started, the Log In dialog box displays. 21. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 22. Click Login. 23.
Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on UNIX systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10.
2 Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on UNIX systems 14. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 45 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Professional Plus edition 10.3.X on UNIX systems 2 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 46 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on Windows systems 20. Click Finish. After all of the selected services are started, the Log In dialog box displays. 21. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 22. Click Login. 23. Click OK on the Login Banner. Migrating from Professional edition 10.3.X to Enterprise trial 10.3.
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on Windows systems 2 8. Choose one of the following options to migrate data from a previous version. To migrate data from a previous management application, you must do so now. • To migrate data from the previous version installed (automatically detected), select Yes, from DCFM in the following location.
2 Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on Windows systems 15. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 47 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on Windows systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 48 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on UNIX systems 19. Verify your configuration and license information on the Server License Summary screen and click Next. 20. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 21. Click Next on the Apply User Settings screen. 22. Select the Start DCFM Client check box, if necessary, on the Start Server screen and click Finish.
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on UNIX systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10.
2 Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on UNIX systems 15. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 49 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X on UNIX systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 50 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on Windows systems 19. Verify your configuration and license information on the Server License Summary screen and click Next. 20. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 21. Click Next on the Apply User Settings screen. 22. Select the Start DCFM Client check box, if necessary, on the Start Server screen. 23. Click Finish.
Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on Windows systems 2 5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install. 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7. Click Next on the Welcome screen. 8. Choose one of the following options to migrate data from a previous version.
2 Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on Windows systems 14. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 51 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on Windows systems 2 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 52 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on UNIX systems 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 20. Click Next on the Apply User Settings screen. 21. Select the Start DCFM Client check box, if necessary, on the Start Server screen and click Finish.
Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on UNIX systems 2 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10.
2 Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on UNIX systems 14. Complete the following steps on the Server IP Configuration screen. Current selection reflects the Professional edition configuration. FIGURE 53 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional edition 10.3.X to Enterprise edition 10.3.X on UNIX systems 2 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 54 a. Server Port Configuration screen Enter a port number in the Syslog Port # field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Professional Plus trial migration 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 20. Click Next on the Apply User Settings screen. 21. Select the Start DCFM Client check box, if necessary, on the Start Server screen. 22. Click Finish. After all of the selected services are started, the Log In dialog box displays. 23.
Upgrading Professional Plus trial to Professional Plus edition TABLE 12 2 Migration Paths Current Software Release To Software Release Migration Procedures Professional Plus trial on Windows systems Enterprise trial To migrate from Professional Plus trial to Enterprise trial, review the following sections: • “Professional Plus trial pre-migration requirements on Windows systems” on page 122 • “Migrating from Professional Plus trial to Enterprise trial on Windows systems” on page 131 Professional P
2 Professional Plus trial pre-migration requirements on Windows systems 6. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 7. Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in. 8. Click Login. 9. Click OK on the Login Banner.
Migrating from Professional Plus trial to Professional Plus edition on Windows systems 2 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7. Click Next on the Welcome screen. 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11.
2 Migrating from Professional Plus trial to Professional Plus edition on Windows systems 13. Complete the following steps on the Server IP Configuration screen. FIGURE 55 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Professional Plus trial to Professional Plus edition on Windows systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 56 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Professional Plus trial pre-migration requirements on UNIX systems 17. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 18. Click Login. 19. Click OK on the Login Banner.
Migrating from Professional Plus trial to Professional Plus edition on UNIX systems 2 • Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=:0.0). You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host.
2 Migrating from Professional Plus trial to Professional Plus edition on UNIX systems 8. Choose one of the following options to migrate data from a previous version. • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a.
Migrating from Professional Plus trial to Professional Plus edition on UNIX systems 2 13. Complete the following steps on the Server IP Configuration screen. FIGURE 57 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus trial to Professional Plus edition on UNIX systems 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 58 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Professional Plus trial to Enterprise trial on Windows systems 2 17. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 18. Click Login. 19. Click OK on the Login Banner.
2 Migrating from Professional Plus trial to Enterprise trial on Windows systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
Migrating from Professional Plus trial to Enterprise trial on Windows systems 2 14. Complete the following steps on the Server IP Configuration screen. FIGURE 59 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus trial to Enterprise trial on Windows systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 60 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Professional Plus trial to Enterprise trial on UNIX systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Professional Plus trial to Enterprise trial on UNIX systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
Migrating from Professional Plus trial to Enterprise trial on UNIX systems 2 14. Complete the following steps on the Server IP Configuration screen. FIGURE 61 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus trial to Enterprise trial on UNIX systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 62 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Professional Plus trial to Enterprise edition on Windows systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Professional Plus trial to Enterprise edition on Windows systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a.
Migrating from Professional Plus trial to Enterprise edition on Windows systems 2 13. Complete the following steps on the Server IP Configuration screen. FIGURE 63 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus trial to Enterprise edition on Windows systems 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 64 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Professional Plus trial to Enterprise edition on UNIX systems 2 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Professional Plus trial to Enterprise edition on UNIX systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
Migrating from Professional Plus trial to Enterprise edition on UNIX systems 2 13. Complete the following steps on the Server IP Configuration screen. FIGURE 65 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus trial to Enterprise edition on UNIX systems 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 66 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Professional Plus edition migration 2 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 20.
2 Professional Plus edition pre-migration requirements on Windows systems 3. Click Update. 4. Click OK on the message. 5. Open the application (double-click the desktop icon or open from the Start menu). The Log In dialog box displays. 6. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 7.
Migrating from Professional Plus edition to Enterprise edition on Windows systems 2 4. Select the usual location for your system’s application files (for example, D:\Program Files\DCFM 10.3.X) or the location of the partially uninstalled Professional Plus edition on the Select Install Folder screen and click Next. Do not install to the root directory (for example, C:\). 5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install. 6.
2 Migrating from Professional Plus edition to Enterprise edition on Windows systems 12. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. The default selection reflects the previous Professional Plus edition configuration. If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service.
Migrating from Professional Plus edition to Enterprise edition on Windows systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 68 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Professional Plus edition pre-migration requirements on UNIX systems 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively.
Migrating from Professional Plus edition to Enterprise edition on UNIX systems 2 • Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=:0.0). You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host.
2 Migrating from Professional Plus edition to Enterprise edition on UNIX systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a.
Migrating from Professional Plus edition to Enterprise edition on UNIX systems 2 13. Complete the following steps on the Server IP Configuration screen. FIGURE 69 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Professional Plus edition to Enterprise edition on UNIX systems 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 70 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise trial migration 2 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 20. Click Login.
2 TABLE 14 Upgrading Enterprise trial to Enterprise edition Migration Paths Current Software Release To Software Release Enterprise trial 10.X.X on Windows systems Enterprise edition 10.3.X Enterprise trial 10.X.X on UNIX systems Enterprise edition 10.3.
Enterprise pre-migration requirements on Windows systems 2 Enterprise pre-migration requirements on Windows systems Before you migrate from Enterprise trial, complete the following: • Make sure that you fully back up your current Management application data on your management server. • Make sure you close all instances of the application before upgrading. • Perform a partial uninstall of the Enterprise trial: a. Select Start > Programs > DCFM 10.3.X > Uninstall DCFM from the DCFM server. b.
2 Migrating from Enterprise trial to Enterprise trial on Windows systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
Migrating from Enterprise trial to Enterprise trial on Windows systems 2 14. Complete the following steps on the Server IP Configuration screen. FIGURE 71 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Enterprise trial to Enterprise trial on Windows systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 72 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Enterprise trial to Enterprise edition on Windows systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Enterprise trial to Enterprise edition on Windows systems 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
Migrating from Enterprise trial to Enterprise edition on Windows systems 2 13. Complete the following steps on the Server IP Configuration screen. FIGURE 73 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from Enterprise trial to Enterprise edition on Windows systems 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 74 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise pre-migration requirements on UNIX systems 2 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Enterprise trial to Enterprise trial on UNIX systems • Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=:0.0). You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host.
Migrating from Enterprise trial to Enterprise trial on UNIX systems 2 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
2 Migrating from Enterprise trial to Enterprise trial on UNIX systems 14. Complete the following steps on the Server IP Configuration screen. FIGURE 75 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Enterprise trial to Enterprise trial on UNIX systems 2 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 76 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Migrating from Enterprise trial to Enterprise edition on UNIX systems 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
Migrating from Enterprise trial to Enterprise edition on UNIX systems 2 8. Choose one of the following options: • If data is detected on your system, a message displays. Click Yes on the message and click Next on the Partial Data Migration screen. Go to step 11. • If data is not detected, the Copy Data and Settings screen displays. Complete the following steps. a. Select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory.
2 Migrating from Enterprise trial to Enterprise edition on UNIX systems 13. Complete the following steps on the Server IP Configuration screen. FIGURE 77 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
Migrating from Enterprise trial to Enterprise edition on UNIX systems 2 14. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 78 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Troubleshooting Linux installation 17. Verify your configuration and license information on the Server License Summary screen and click Next. 18. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 19. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 20.
Enterprise edition migration 2 Enterprise edition migration NOTE Enterprise edition to Professional edition migration is not supported. Use the following table to migrate data from Enterprise edition. TABLE 15 Migration Paths Current Software Release To Software Release Migration Procedures Enterprise edition 10.0.X on Windows systems Enterprise edition 10.3.X on Windows systems To migrate from Enterprise edition 10.0.X to Enterprise edition 10.3.
2 Migrating from Enterprise edition 10.0.X on Windows systems Migrating from Enterprise edition 10.0.X on Windows systems NOTE Migration of FC port performance statistics is only supported only from DCFM 10.1.4 to 10.3.0. It is not supported from 10.0.x to 10.3.0 or 10.1.1, 10.1.2, and 10.1.3 to 10.3.0. Use the following procedure to migrate from Enterprise edition 10.0.X software to Enterprise edition 10.3.X software on a Windows management server. 1. Insert the installation DVD into the DVD-ROM drive.
Migrating from Enterprise edition 10.0.X on Windows systems 2 10. Click Start on the Data Migration screen. Data migration may take up to 30 minutes. When data migration is complete, the previous version is partially uninstalled. 11. Click Next on the Data Migration screen. 12. Enter the serial number (located on the DVD jewel case) and license key (located on the Key Certificate) on the Server License screen or browse to the license file (.xml) and click Next. The License Key field is not case-sensitive.
2 Migrating from Enterprise edition 10.0.X on Windows systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 80 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Enterprise edition pre-migration requirements on UNIX systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Enterprise edition 10.0.X on UNIX systems Migrating from Enterprise edition 10.0.X on UNIX systems NOTE Migration of FC port performance statistics is only supported only from DCFM 10.1.4 to 10.3.0. It is not supported from 10.0.x to 10.3.0 or 10.1.1, 10.1.2, and 10.1.3 to 10.3.0. Use the following procedure to migrate from Enterprise edition 10.0.X software to Enterprise edition 10.3.X software on a UNIX management server. 1.
Migrating from Enterprise edition 10.0.X on UNIX systems 2 12. Enter the serial number (located on the DVD jewel case) and license key (located on the Key Certificate) on the Server License screen or browse to the license file (.xml) and click Next. The License Key field is not case-sensitive. 13. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. The default selection reflects the previous Enterprise configuration. If port 21 is busy, a message displays.
2 Migrating from Enterprise edition 10.0.X on UNIX systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 82 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Enterprise edition 10.1.X on Windows systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Enterprise edition 10.1.X on Windows systems 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10.
Migrating from Enterprise edition 10.1.X on Windows systems 2 14. Complete the following steps on the Server IP Configuration screen. FIGURE 83 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
2 Migrating from Enterprise edition 10.1.X on Windows systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 84 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Migrating from Enterprise edition 10.1.X on UNIX systems 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively.
2 Migrating from Enterprise edition 10.1.X on UNIX systems 9. Click Next on the Copy Data and Settings screen. An error message displays if any of the following occur: Error Fix Selected location is not valid or not supported. Browse to the correct location of the application. Upgrade to a supported version. NOTE If legacy EFCM or FM software exist in the system, an Uninstall screen displays. Click Yes to uninstall services of legacy EFCM and FM software. 10. Click Start on the Data Migration screen.
Migrating from Enterprise edition 10.1.X on UNIX systems 2 14. Complete the following steps on the Server IP Configuration screen. FIGURE 85 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
2 Migrating from Enterprise edition 10.1.X on UNIX systems 15. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 86 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
EFCM migration 2 18. Verify your configuration and license information on the Server License Summary screen and click Next. 19. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 20. Enter your user name and password. The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change. 21. Click Login. 22.
2 EFCM migration The following table lists the data and configurations available in EFCM and identifies which ones are migrated.
EFCM migration TABLE 17 2 Data migrated from EFCM Option Data Migrated? Output Format Affected Features Memory Allocation Client memory allocation Server memory allocation N EFCM Server and Client Server Connection Server connection port Server Export port SSL Enable Server Export SSL Port N N Y N SNMP Discovery Timeout and Retry Y DB Discovery SNMP Trap Listening Trap listening port Y DB Fault Management Support mode Enable client and server debug logs Enable or disable run time
2 EFCM migration TABLE 17 Data migrated from EFCM Option Data Migrated? Output Format Affected Features Port label (client) Nickname Name Port Number Port Address Port WWN Y DB EFCM Client Port display (client) Occupied Unoccupied Attached Y DB Device Tree and Topology Fabric Persistence (Server) Fabric Persistence N Discovery Discovery list Subnet IPs Individual IPs Auth vault Only individual switch IP addresses belonging to mixed fabrics (along with discovery credentials) are migra
EFCM migration TABLE 17 2 Data migrated from EFCM Option Zone Data Migrated? Output Format Zone Y Export Export settings N View Utilization Enable and disable view utilization E-mail Event Notification Call home / Advanced Call Home Affected Features DB Zoning Y DB Performance Management E-mail server SMTP configuration Reply E-mail ID Y DB Fault Management Call centers information Products assigned to call centers Filters Display call center information.
2 EFCM migration TABLE 17 Data migrated from EFCM Option Data Migrated? Client Configuration VM Parameters Y Only parameters which change the user interface. For example, export port number or file transfer time out. User defined columns All user-defined columns Y User preferences smp.properties N Core model information MeService.
Pre-migration requirements on Windows systems 2 Pre-migration requirements on Windows systems Before you migrate from EFCM, complete the following: • Make sure you have obtained the DCFM license key and serial number. To obtain these contact your preferred storage vendor. • Make sure that a version of EFCM is installed on your server that meets migration requirements. You may also need to upgrade E/OS versions on supported switches and directors. NOTE If you have EFCM 9.
2 Migrating from EFCM 9.6 or 9.7 on Windows systems 4. Select the usual location for your system’s application files (for example, D:\Program Files\DCFM 10.3.X) on the Select Install Folder screen and click Next. Do not install to the root directory (for example, C:\). 5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install. 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7.
Migrating from EFCM 9.6 or 9.7 on Windows systems 2 16. Complete the following steps on the Server IP Configuration screen. Current selection reflects the EFCM configuration. FIGURE 87 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next.
2 Migrating from EFCM 9.6 or 9.7 on Windows systems 17. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 88 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
Pre-migration requirements on UNIX systems 2 20. Verify your configuration and license information on the Server License Summary screen and click Next. 21. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 22. Click Next on the Apply User Settings screen. 23. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 24.
2 Pre-migration requirements on UNIX systems • Make sure you close all instances of the application before upgrading. Shut down EFCM on the management server, as well as on all remote workstations. If you still receive error messages after closing the application, enter the following commands: #ps -ef | grep -i “” to list the process ID #kill -9 “process ID” • Check for and install the latest Java patches for your operating system. DCFM requires JRE 1.6.0.
Migrating from EFCM 9.6 or 9.7 on UNIX systems 2 Migrating from EFCM 9.6 or 9.7 on UNIX systems Use the following procedure to migrate from EFCM 9.6 or 9.7 software to DCFM Enterprise edition on a UNIX management server. 1. Insert the installation DVD into the DVD-ROM drive and open the following file. \DCFM\\install.bin 2. Click Next on the Introduction screen. 3.
2 Migrating from EFCM 9.6 or 9.7 on UNIX systems 15. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next. The default selection reflects the previous EFCM configuration. If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service.
Migrating from EFCM 9.6 or 9.7 on UNIX systems 2 17. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 90 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Importing names 20. Verify your configuration and license information on the Server License Summary screen and click Next. 21. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 22. Click Next on the Apply User Settings screen. 23. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 24. Enter your user name and password.
Editing a user account 2 To import names, complete the following steps. 1. Select Configure > Names. The Configure Names dialog box displays. 2. Click Import. The Import Files dialog displays. 3. Browse to the .properties file location. 4. Select the .properties file and click Import. 5. Click OK to save your work. 6. Click OK on the confirmation message.
2 Fabric Manager migration 6. Repeat step 2 through step 5 for each user role you want to edit. 7. Click OK to close the Server Users dialog box. Fabric Manager migration NOTE Data migration to Enterprise edition is only available from Fabric Manager 5.4 and 5.5. NOTE You cannot migrate from Fabric Manager to Professional or Professional Plus. You must migrate to the Enterprise trial or Enterprise edition. NOTE If you have Fabric Manager 5.3 or earlier software, you must upgrade to Fabric Manager 5.
Pre-migration requirements on Windows systems 2 Pre-migration requirements on Windows systems Before you migrate from Fabric Manager, complete the following: • Make sure that a version of Fabric Manager is installed on your server that meets migration requirements. For information about upgrading to a version of Fabric Manager that meets migration requirements, refer to the Upgrade Instructions for Fabric Manager. You may also need to upgrade FOS versions on supported switches and directors.
2 Migrating from Fabric Manager 5.4 or 5.5 on Windows systems 11. Click Start on the Data Migration screen. Data migration may take up to 30 minutes. When data migration is complete, the Fabric Manager services are uninstalled. 12. Click Next on the Data Migration screen. 13. Enter the serial number (on the DVD jewel case) and license key (on the Key Certificate) on the Server License screen or browse to the license file (.xml) and click Next. The License Key field is not case-sensitive. 14.
Migrating from Fabric Manager 5.4 or 5.5 on Windows systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 92 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Post migration requirements on Windows systems 19. Verify your configuration and license information on the Server License Summary screen and click Next. 20. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 21. Click Next on the Apply User Settings screen. 22. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 23.
Migrating from Fabric Manager 5.4 or 5.5 on UNIX systems 2 6. Make sure the Launch DCFM Configuration check box is selected (default) on the Installation Complete screen, and click Done. 7. Click Next on the Welcome screen. 8. To migrate data from Fabric Manager, select Yes, from EFCM, FM, or DCFM installed in this machine or on network and click Browse to browse to the installation directory. To migrate data from a previous management application, you must do so now. 9.
2 Migrating from Fabric Manager 5.4 or 5.5 on UNIX systems 15. Complete the following steps on the Server IP Configuration screen. FIGURE 93 Server IP Configuration screen a. Select an address from the Client - Server IP Configuration Return Address list. b. Select an address from the Switch - Server IP Configuration Preferred Address list. c. Click Next. If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list.
Migrating from Fabric Manager 5.4 or 5.5 on UNIX systems 2 16. Complete the following steps on the Server Port Configuration screen. NOTE Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server. FIGURE 94 a. Server Port Configuration screen Enter a port number in the Syslog Port Number field (default is 514). NOTE If the default syslog port number is already in use, you will not receive any syslog messages from the device. b.
2 Post migration requirements on UNIX systems 19. Verify your configuration and license information on the Server License Summary screen and click Next. 20. Click Start on the Apply User Settings screen. User Settings migration may take up to 30 minutes. 21. Click Next on the Apply User Settings screen. 22. Select the Start Client check box, if necessary, on the Start Server screen and click Finish. After all of the DCFM services are started, the Log In dialog box displays. 23.
Chapter 3 Transition In this chapter • EFCM transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 • Fabric Manager transition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 • WebTools Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 EFCM transition The visual differences between EFCM and DCFM are minor.
3 EFCM transition FIGURE 96 DCFM main interface 1. Menu Bar - Lists commands you can perform on the SAN. 2. Toolbar - Provides buttons that enable quick access to dialog boxes and functions. 3. View All tab - Displays the Master Log, Minimap, Physical Map (topology), and Product List. 4. Product List - Lists the devices discovered in the SAN. 5. Event Management tab - Not implemented in DCFM. 6. Security tab - Not implemented in DCFM. 7.
Toolbar differences 3 Toolbar differences FIGURE 97 EFCM toolbar The only differences between the EFCM and DCFM toolbars are that the Discovered SAN and Planned SAN features have not been implemented in DCFM, and the Export function has been moved to individual dialog boxes. FIGURE 98 DCFM Toolbar The buttons on your toolbar will vary based on the licensed features on your system. 1. Users - Displays the Server Users dialog box. Use to configure users, user groups, and permissions. 2.
3 EFCM to DCFM command mapping EFCM to DCFM command mapping The following table details the changes in menu command mapping between EFCM and DCFM as well as showing which commands were not implemented. TABLE 20 EFCM to DCFM command mapping Menu EFCM Menu Command DCFM Menu Command Comment SAN Logout Exit The client now only communicates with one server. Shutdown Start > Programs > DCFM > Server Management Console > Services tab The client cannot be used to shut down the server.
EFCM to DCFM command mapping TABLE 20 Menu View Plan Discover 3 EFCM to DCFM command mapping EFCM Menu Command DCFM Menu Command Comment Select Connected Set Not implemented. Select All Select All No change. Properties Properties No change. Discovered SAN Not implemented. Planned SAN Not implemented. Show Panels Show Panels No change. Manage View > Create View Manage View > Create View No change.
3 EFCM to DCFM command mapping TABLE 20 Menu Configure EFCM to DCFM command mapping EFCM Menu Command DCFM Menu Command Comment Setup Setup Uses Seed Switch discovery; only one IP address is necessary to discover an entire fabric. Added Monitor/Unmonitor, Change Seed Switch, and Delete Fabric functions. Removed in-band discovery. Servers Server Port Mapping Use to map server ports. Storage Port Mapping Storage Port Mapping No change. Map to Hub Not implemented.
EFCM to DCFM command mapping TABLE 20 Menu Monitor 3 EFCM to DCFM command mapping EFCM Menu Command DCFM Menu Command Comment FC Troubleshooting > Trace Route New function. Use to trace routes and FC Ping between two ports. FC Troubleshooting > Device Connectivity New function. Use to troubleshoot device connectivity within a fabric. FC Troubleshooting > Fabric Device Sharing New function. Use to troubleshoot device connectivity across fabrics. IP Troubleshooting > Ping New function.
3 EFCM to DCFM command mapping TABLE 20 Menu Tools Help 226 EFCM to DCFM command mapping EFCM Menu Command DCFM Menu Command Comment Logs Logs Added FICON and Syslog logs. Removed Group and Session logs. Persist Fabric Unpersist Fabric Track Fabric Changes Use to track fabric changes. Unpersist Product Accept Change(s) Use to accept fabric changes. Show Route Hide Route FC Troubleshooting > Trace Route Use to trace routes and FC Ping between two ports. Port Connectivity New function.
Fabric Manager transition 3 Fabric Manager transition The visual differences between Fabric Manager and DCFM are large. Many of the functions remain, but the information is arranged very differently and often accessed in a different way. FIGURE 99 FM main interface 1. Menu Bar - Lists commands you can perform on the SAN. 2. Scope panel - Provides fields and values you can use to define the SAN view in the View panel. 3.
3 Fabric Manager transition FIGURE 100 DCFM main interface 1. Menu Bar - Lists commands you can perform on the SAN. 2. Toolbar - Provides buttons that enable quick access to dialog boxes and functions. 3. View All tab - Displays the Master Log, Minimap, Connectivity Map (topology), and Product List. 4. Product List - Lists the devices discovered in the SAN. 5. Connectivity Map - Displays the SAN topology, including discovered and monitored devices and connections. 6.
Fabric Manager to DCFM command mapping 3 Fabric Manager to DCFM command mapping The following table details the changes in menu command mapping between Fabric Manager and DCFM as well as showing which commands were not implemented. TABLE 22 Fabric Manager to DCFM command mapping Menu Fabric Manager DCFM Comments File New Not implemented. Export to SVG Not implemented. Print Topology Not implemented. Print Preview Not implemented.
3 Fabric Manager to DCFM command mapping TABLE 22 Menu 230 Fabric Manager to DCFM command mapping Fabric Manager DCFM Comments Fabric Management > Fabric Merge Not implemented. Fabric Management > Fabrics Merge Check Not implemented. Fabric Management > Manage Security Not implemented. Fabric Management > Change Seed Switch Discover > Setup > Change Seed Switch No change. FC Router Management > FC Router Configuration Configure > Routing Configuration No change.
Fabric Manager to DCFM command mapping TABLE 22 Menu Reports Help 3 Fabric Manager to DCFM command mapping Fabric Manager DCFM Comments Capture Tech Support Information Monitor > Technical Support > Collect Data No change. Cascaded FICON Setup Configure > FICON > Configure Fabrics No change. Cascaded FICON Setup > merge two fabrics for Cascaded FICON setup Configure > FICON > Merge Fabrics No change. Cascaded FICON Setup > IOD Setup Not implemented.
3 WebTools Functionality WebTools Functionality Some functionality formerly residing in the WebTools 6.0 application has been moved to DCFM. The following table details these changes. TABLE 23 WebTools functionality Function WebTools 6.0 DCFM Comments FCIP Tunnel Configuration Port Admin Module > GigE tab Configure > FCIP Tunnel Viewing FCIP tunnels is still supported in WebTools 6.1.1, but New, Edit Config, and delete are only available in DCFM.
WebTools Functionality TABLE 23 3 WebTools functionality Function WebTools 6.0 DCFM Add Un-Zoned Devices Zone Admin Configure > Zoning Reverse Find in the Zoning dialog provides the view of the zoned and unzoned devices in the fabric if all zone members are selected for Find. Non-local switch ports display in zoning tree Zone Admin Configure > Zoning DCFM Installation, Migration, and Transition Guide 53-1001360-01 Comments In WebTools, non-local switch port ID/WWN can be added using text box.
3 234 WebTools Functionality DCFM Installation, Migration, and Transition Guide 53-1001360-01
Index B browser requirements installation, 7 C command mapping EFCM to DCFM, 222 Fabric Manager to DCFM, 229 configuring explicit server IP address, 60 correcting the default Linux Smart Card driver, 62 D Enterprise edition installation, 29, 34, 38, 49, 54, 59 installation on Windows, 29, 49 migration to Enterprise edition on Windows, 178, 185 pre-installation, 37, 58 pre-installation requirements, UNIX, 33, 53 Enterprise trial edition installation, 19, 28, 39, 48 installation for UNIX, 24, 44 installat
Index L P Linux installation troubleshooting, 18 Linux migration, troubleshooting, 176 local client, Smart Card driver install, 60 PC/SC IFD driver, 60 pcscd daemon, 61 post-migration requirements Fabric Manager on UNIX, 218 Fabric Manager on Windows, 214 pre-installation Enterprise edition on UNIX, 33, 53 Enterprise trial edition on UNIX, 23, 43 pre-migration requirements EFCM UNIX, 203 Windows, 199 Enterprise trial edition UNIX, 126, 152, 167, 181 Windows, 122, 148, 159, 177 Fabric Manager UNIX, 214 W
Index R U remote client, Smart Card driver install, 62 requirements Enterprise trial edition, 120, 157 post migration Fabric Manager on UNIX, 218 post-migration Fabric Manager on Windows, 214 pre-migration EFCM on UNIX, 203 EFCM on Windows, 199 Enterprise trial edition on UNIX, 126, 152, 167, 181 on Windows, 177 Enterprise trial edition on Windows, 122, 148, 159 Fabric Manager on UNIX, 214 Fabric Manager on Windows, 211 Professional edition on UNIX, 76 Professional edition on Windows, 72 uninstalling DC
Index Windows migration EFCM pre-migration requirements, 199 EFCM to DCFM, 199 Enterprise edition to Enterprise edition, 178, 185 Enterprise trial edition pre-migration requirements, 122, 148, 159, 177 to Enterprise edition, 122, 131, 139, 148, 159, 163 Fabric Manager post-migration requirements, 214 Fabric Manager pre-migration requirements, 211 Fabric Manager to DCFM, 211 Professional edition pre-migration requirements, 72 Professional edition to Enterprise edition, 88, 96, 104, 112 Professional edition