HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Replacement of a CP card in the 4/256 Director may cause disruption of I/O traffic. HP
recommends that the CP be replaced during a scheduled downtime to prevent disruption
in FICON environments.
Firmware
Downloads
The CUP device must be varied offline to all MVS partitions before starting a code load.
The CUP device can be varied back online after the code load completes. Failure to vary
off the CUP devices may result in a CP panic.
Firmware
Downloads
In a mixed fabric environment, an M-EOS switch must be the principal switch if the fabric
is in Interopmode 2 (McDATA Fabric Mode) .
Manageability
Port Fencing should be used to avoid taking ports down for normal fabric events. The
recommended fencing criteria and settings are listed in Table 7.
Manageability
Firmware download is executed sequentially if DCFM is used for downloading code to
Fabric OS switches.
Manageability
As a best practice for deploying Fabric OS switches and directors into a FICON environment,
verify the Fabric OS version shipped with the most current Fabric OS recommendation. HP
recommends that you update all Fabric OS switches and directors to the same Fabric OS
levels for production.
Manageability
The remote CUP may not work when the channel is connected to an 8G blade on a 4/256
director cascaded to a remote switch.
Manageability
FMS must be enabled on the local switch for the remote CUP to work.
Manageability
HP recommends using 50 micron multimode fiber optic cabling rated at 2000 MHz-km
(OM3 fiber) for connecting to 8 Gb/s short wavelength (SX) small form factor pluggable
optics (SFPs). Other 50 micron and 62.5 micron multimode fiber may be used as an
alternative, but distance limitations may exist.
Optics
Performance of optical links depends on the cleanliness of the cables and connectors,
especially at 8 Gb/s or higher speeds. For proper cable maintenance, consult your switch
and cable vendors.
Serviceability
The 8Gb 48 port blade is supported as follows:
The switch, or logical switch, must be configured for Brocade Native mode (interopmode
0).
Only on VF-enabled chassis on the DC SAN Director.
Not supported in the default switch on the DC SAN Director.
Serviceability
Enable Lossless DLS when activating Traffic Isolation (TI) Zones to avoid any traffic disruption.
Traffic Isolation
Zones
Traffic Isolation (TI) Zoning with FICON supports enabling or disabling of the failover option.
Seek assistance from service support before attempting to enable this feature.
Traffic Isolation
Zones
Table 7 Recommended fencing criteria
ValueCriteria
25ITW (Invalid Transmission Words)
3CRC (Cyclical Redundancy Check)
HP StorageWorks Fabric OS 6.3.0d Release Notes 33