Fixed in Fabric OS 6.3.0
Workaround prior to code change:
When performing a rekeying
operation on the LUN, HP
recommends that you quiesce access
to that LUN.
Applications that write to a LUN that is being rekeyed may see I/O
errors.
Fixed in Fabric OS 6.3.0
Rekey of LUNs hosted through active/passive ports do not complete
if started on the passive path.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
This is due to multiple devices logging
in simultaneously. So apply
portdisable to all ports connected
to the devices and apply
portenable sequentially. This will
resolve the issue. NPIV devices in
Interopmode 2 default zone is not
supported. NPIV devices should be
part of the active zone configuration.
With McDATA default zone enabled, when numerous NPIV devices
in the default zone come online at the same time, some devices were
missing from the portcam table.
Fixed in Fabric OS 6.3.0
Fabric mode TT does not show all the flows when device port is dis-
abled and enabled back after TT monitor installation.
Fixed in Fabric OS 6.3.0
If using WebTools to perform cfgsaveactivetodefined with a zone file
close to the maximum size in an interop mode fabric with more than
20 switches, the weblinker process may get terminated.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Follow the raslog errors FABR-1044
or FABR-1043 displayed by switches
in the fabric to identify the offending
switch and resolve the FID conflict.
In a mixed fabric of VF enabled and non-VF switches, a VF enabled
switch may not be able to detect the FID conflict with the other VF en-
abled switch, if there are non-VF switches in the path interconnecting
the VF enabled switches.
Fixed in Fabric OS 6.3.0
IPC message from module CALD to Management Server is dropped
by Management server. This causes CALD module to wait indefinitely.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Disable the switch and then attempt
configdownload.
Sometimes config file downloaded may cause the configdownload
command to crash.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Do not disable a switch immediately
after enabling if it's coming up with
a new FID for the first time. Wait for
at least 10 seconds before issuing
switchdisable.
After changing FID on HP StorageWorks 8/40 SAN Switch and then
performing switchenable, switchdisable, observed ASSERT.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Reboot the Encryption SAN Switch.
HA cluster member node, HP StorageWorks Encryption SAN Switch
faults as a result of slot power cycling its HA cluster peer (HP Storage-
Works DC Encryption FC Blade).
46