HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
Command fddcfg –fabwideset and other security commands fail
with RCS transaction error.
Fixed in Fabric OS 6.3.0
With tape pipelining active, the switch may return a good status without
sending data.
Fixed in Fabric OS 6.3.0
DC SAN Director ASIC parity errors, ICL CRC's and IFCC's on
overnight workload.
Fixed in Fabric OS 6.3.0
Host detecting IFCCs errors to CUP Port.
Fixed in Fabric OS 6.3.0
Workaround prior to code change: A
workaround to facilitate execution of
admin level CLI commands using ssh,
is to use syntax similar to: ssh -l admin
192.168.1.12 "rbash --login -c
'switchshow'" Or if a command is
needed that works on both older
(correctly operating) Fabric OS and
the newer/affected FOS: ssh -l admin
192.168.1.12 "switchshow || rbash
--login -c 'switchshow'"
Sshd allows admin login to execute root level Linux commands but not
admin CLI commands.
Fixed in Fabric OS 6.3.0
Encryption SAN Switch goes faulty as a result of alternately rebooting
the two Encryption SAN Switches that have all the physical connectiv-
ities to the targets and initiators.
Fixed in Fabric OS 6.3.0
Encryption SAN Switch went Faulty when starting traffic.
Fixed in Fabric OS 6.3.0
SAK/IRNDUP fails with Port Address Name miscompare on CUP Port
x'FE'
Fixed in Fabric OS 6.3.0
Detected termination of process fabricd:4820
Fixed in Fabric OS 6.3.0
Pending Merge: Disconnecting and reconnecting the ISL on Encryption
SAN Switch while rekey in progress may result in new key creation
failure.
Fixed in Fabric OS 6.3.0
Encryption SAN Switch shows Encryption Engine busy when continu-
ously and repeatedly disabling and enableing I/O sync ports of the
Encryption SAN Switch.
Fixed in Fabric OS 6.3.0
Node descriptors are missing for DC SAN Director and DC04 SAN
Director.
Fixed in Fabric OS 6.3.0
Tape pipelining code begins to randomly send only data frames in an
exchange to tape drive.
Fixed in Fabric OS 6.3.0
Partitioned DC04 SAN Director panicked after reset allegiance issued
by multiple hosts.
Fixed in Fabric OS 6.3.0
Rolling ASSERT+PANIC on DC SAN Director with DC Switch Encryption
blade faulty when going from 6.1.2 to 6.2.0d.
Fixed in Fabric OS 6.3.0
Portswap not working for ports 32-47 on 48 port blade.
Fixed in Fabric OS 6.3.0
VI to PT routes are deleted following portdisable and portenable
on a 48port 4Gb blade.
50