HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0
Following a reboot of all nodes in an Encryption Group (EG) with
current and pending rekeys, single rekey session did not resume.
Fixed in Fabric OS 6.3.0
Verify fab_ha.c line 5206 on 10G Adva link connect.
Fixed in Fabric OS 6.3.0
"Enable Inactive port" tab in the EZmanager has to be disabled for
the 2408 FCoE CN Switch.
Fixed in Fabric OS 6.3.0
8/8 or 8/16 SAN Switch not responding to Link Reset primitives cor-
rectly.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
New master incorrectly reported as
offline or faulty after trunk master
disable. No workaround, hafailover
can be used as recovery.
When a trunk master port is disabled, fabric watch incorrectly sets the
new trunk masters health to offline, and remote side to faulty even
though port is online.
Fixed in Fabric OS 6.3.0
CAL Response for Brocade_ISL CAL class is returning wrong port in-
formation in case of Edge to Backbone Device Sharing (when TD is
available in FCR fabric).
Fixed in Fabric OS 6.3.0
Console is not accessible on 8GB SAN Switch for HP BladeSystem c-
Class.
Fixed in Fabric OS 6.3.0
Blade fault observed with a 4/256 SAN Director chassis fully loaded
with 8Gb 48-port blades.
Fixed in Fabric OS 6.3.0
Deleted offline/inactive device using zone validate window in EZman-
ager is not replicated in CLI.
Fixed in Fabric OS 6.3.0
Encryption SAN Switch and Encryption FC blade do not support en-
crypted LUNs >2TB.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
View the switch events to determine
the reason for failure.
Switch Admin: Proper error message should pop up when disabling
of FCoE in a VLAN fails.
Fixed in Fabric OS 6.3.0
Switch panic when supportsave read invalid data on GE ports without
FC Fastwrite enabled.
Fixed in Fabric OS 6.3.0
Workaround prior to code change: 1.
Avoid using firmwaredownload -sb
i.e. avoid auto-reboot. Use
firmwaredownload -s and then do a
manual reboot. 2. Need to power
cycle the switch. The switch functions
properly after power cycle with
normal access to the telnet session.
Firmware downgrade from Fabric OS 6.2.0 to 6.1.0 sometimes causes
an unresponsive console, which requires a switch power cycle to re-
cover.
Fixed in Fabric OS 6.3.0
Rekeyed LUNs are in "Not Ready (Getting key from archive)" state
when the key vault goes down and does not recover.
Fixed in Fabric OS 6.3.0
Workaround prior to code change:
Add members with the Add other
button.
WebTools Zone Admin Add member button is always disabled.
58