HP StorageWorks Fabric OS 6.3.3d Release Notes (5697-0493, May 2010 - includes all 6.3.0x versions)

Fixed in Fabric OS 6.3.0a
Software verify error detected appears on console during
upgrade to 6.3.0 from RC builds on HP StorageWorks 8/80 SAN
Switch. This issue will not be seen in the field.
Fixed in Fabric OS 6.3.0a
Retransmit and Out of Order counters displayed in the portshow
fciptunnel command do not show correct values.
Fixed in Fabric OS 6.3.0a
If the first circuit in the first tunnel is not numbered 0, portshow
fciptunnel all -c displays incorrect value (adds line 16 0 un-
knwn Disable ---- 0s 0.00 0.00 0 0/0 0).
Fixed in Fabric OS 6.3.0a
With 1606 Extension SAN Switch or Multiprotocol Extension Blade,
FCIP configuration cannot be restored to default setting by using
configdefault, even after chassis reboot.
Fixed in Fabric OS 6.3.0a
HP StorageWorks Encryption SAN Switch or encryption blade drops
frames received from the host when the back-end tape becomes unre-
sponsive.
Fixed in Fabric OS 6.3.0a
HP StorageWorks Multiprotocol Extension Blade faceplate image in
WebTools 10-GbE ports should be renamed as XGE ports.
Fixed in Fabric OS 6.3.0a
ifName value returned for xGBE port in WebTools does not match
CLI output.
Fixed in Fabric OS 6.3.0a
Workaround prior to code change:
Reduce IT configurations (target
containers with initiators) to 200.
If the ITL nexus in tape (target containers with initiator) to handle multi-
plex/multistream environment is greater than 200, decreased perform-
ance is seen for some containers.
Fixed in Fabric OS 6.3.0a
NPIV tape devices may not be seen by hosts due to name server not
sending subsequent PLOGI ACC following a sequence where NPIV
device sends LOGO before link down.
Fixed in Fabric OS 6.3.0a
Workaround prior to code change:
Use portdisable and
portenable after inserting the
supported SFP.
GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol
Extension Blade will continually showail No_Sync status if non-B-series
SFP was inserted and then replaced with B-series SFP.
Fixed in Fabric OS 6.3.0a
Copper 1-GbE SFP can get into an illegal state on Extension SAN
Switch where no LED light is shown, but port is online and working.
Fabric OS 6.3.0b fixes
Table 12 lists defects closed in the Fabric OS 6.3.0b firmware release.
Table 12 Fabric OS 6.3.0b closed defects
SolutionClosed defect summary
Fixed in Fabric OS 6.3.0b
When an unsupported SFP is installed in an HP StorageWorks DC
SAN Director Multiprotocol Extension Blade, the amber LED flashes to
indicate a fault, as it should. However, if an optical cable is plugged
into the SFP, the amber LED extinguishes. The actual port status is un-
changed.
HP StorageWorks Fabric OS 6.3.0d Release Notes 73