HP StorageWorks Fabric OS 5.3.1a release notes (AA-RWEYJ-TE, May 2008)

AFabricOS5.3.1aconguration le c a nnot be used on the same switch after the switch has
been downgraded to rmware version 5.1.x or 5.2.x.
When you downgrade to Fabric OS 5.0.x, you must also remove additional 5.1.x features and
any installed B-Series MP Router blades.
Important notes
Table 2 prov ides information r elevant to the release.
Table 2 Import
ant release information
Topic Description
ipfilter command
Starting with Fabric OS version 5.3.0, you can use the ipfilter command
to block unauthorized Telnet access. The option to disable Telnet using the
configure command is no longer available.
Use the following command to create a policy to block Telnet access to any station:
ipfilter --create blockTelnet -type ipv4 ipfilter
--addrule blockTelnet -sip any -dp 23 -proto tcp -act deny
ipfilter -- activate blockTelnet
Use the following command to restore default policies for IPv4:
ipfilter --activate default_ipv4 --
See the Fabric OS 5.3.0 command reference guide for more information on the
ipfilter command.
PKI certi
cation
If you have purchased and installed the Secure Fabric OS option, go
to the foll
owing website for information on obtaining a PKI certicate:
h
ttp://www.hp.com/storage/go/secureos.
FICON support
With release 5.2.0 and later, the Switch Connection Control high integrity
requirement for cascading FICON is available in the standard base Fabric OS.
End users can now deploy new cascade FICON Directors without purchasing
a sep arate Secure Fabric OS license.
To add a new FICON Director into existing cascaded congurations already
running Secured Fabric OS, HP recommends that users continue to deploy
Secure Fabric OS on the new FICON Director instead of migrating to FOS ACL
conguration.
NOTE:
The FC4-48 port Blade is not supported to connect to System z environments
vi a FICON channels or via FCP zLinux on System z. To attach the Director
to the System z envir onment , use an FC4-16 or FC4-32 Fibre Channel
port Blade.
Diagnostics backport test
Backport tests may be run only in the following con gurations:
ApureSANDirector2/128(onlyCP2andFC-16blades)
A SAN Director 2/128 with no FC4-16 blades installed, using Option 5.
Do not run backport tests in any conguration other than the two listed above;
usetheminicycletestinstead.
Diagnostics spinsilk test
The following congurations will pass the spinsilk test:
ApureSANDirector2/128(onlyCP2andFC-16blades)
Apure4/256SANDirector,Option5
A pure 4/256 SAN D irector, Option 5 (with FC4-16 blades)
The following congurations will fail thespinsilktest;usetheminicycletestinstead:
A mixed SAN Director 2/128 (with either CP4 or FC4-16 bla des)
Apure4/256SANDirector,Option1(apure4/256SANDirectorrefers
to a Director with CP4 and FC4-16 blades only).
10