HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)

Installing FRUs104
Removing the WWN card
Allow approximately 20 minutes to remove or replace the WWN card. Obtain the following items:
Electrostatic discharge (ESD) grounding strap
#2 Phillips screwdriver (required only for some versions of the WWN card)
The following is required if a serial console session is used: serial cable and a workstation
computer with a terminal emulator application (such as HyperTerminal for Windows systems or
TIP for Solaris systems)
This procedure requires CLI access to the Director via a telnet session or a serial console connection.
1. Open a telnet session and log into the active CP as admin. The default password is password.
NOTE: If a serial console is used, all commands must be entered through the active CP card unless
otherwise indicated. For command details, refer to the Fabric OS command reference manual.
Table 32 WWN card related system log messages
Type of message System message (errshow or errdump)
WWN unit removal was
detected
<timestamp>, [EM-1050], <sequence-number>,,
INFO,
<system-name>, FRU WWN # removal detected.
WWN unit insertion
was detected
<timestamp>, [EM-1049], <sequence-number>,,
INFO,
<system-name>, FRU WWN # insertion detected.
WWN unit fails to
power on
<timestamp>, [EM-1004], <sequence-number>,,
CRITICAL, <system-name>, WWN # failed to power
on
WWN unit is being
faulted
<timestamp>, [EM-1034], <sequence-number>,,
ERROR,
<system-name>, WWN # set to faulty, rc=<return
code>