HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
SAN Director installation guide 109
3. Reinstall the WWN bezel:
a. Orient the bezel on the chassis (see Figure 30 on page 107), insert both retaining screws
into the standoffs on the chassis, and tighten to finger-tight.
NOTE: If a serial console session is active, several removal detected and insertion
detected messages are displayed on the console as a result of the replacement.
b. In the CLI session, enter continue to indicate that the replacement has been completed:
4. Verify that the WWN card is correctly connected by observing the LEDs on the WWN card to
determine if they reflect the status of the components.
NOTE: The LEDs might take up to 2 minutes to begin functioning after WWN card installation.
5. Pack the faulty WWN card in the packaging provided with the new card and return it to HP.
Please enter the word `continue' after the new WWN card has been
installed: continue
Restoring the information to the replacement FRU now, please wait
about 20 seconds to complete
Verifying the replacement FRU now...
WWN card hot swap is now complete.
FRU replacement completed successfully!