HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
Installing FRUs112
NOTE: Enter all remaining commands from the serial console for the active CP card, unless
otherwise indicated. For more information about commands, see the Fabric OS command reference
manual
.
3. If the healthy CP card is acting as the active CP card, go to step 6. If the faulty CP card is
performing as the active CP card, fail over the cards as described here:
a. Login to the faulty CP card as admin, using either a telnet or a serial console connection.
If you connect successfully to the faulty CP continue to step b.
If you cannot connect to the faulty CP, then you can remove the faulty CP card for repair as
follows:
• Turn the CP card off and notify the Director of a hot swap request by sliding the slider
switch in the top ejector down to the off position.
• Then, wait until the active CP LED on the healthy CP card is lit. You can remove the CP for
repair.
b. Type haFailover. The healthy CP card becomes the active CP card.
c. Wait until the status LED on the healthy CP card is no longer lit (indicates failover is
complete).
d. Type haShow from the healthy CP card (the new active CP card) to verify the failover.