Installing FRUs118
5. Type slotShow. The command output shows the new CP card as ENABLED:
6. Type firmwareShow to determine the firmware version.
The following example shows sample output for the firmwareShow command:
7. If the firmware version on the replacement card does not match that on the active CP card, bring
the replacement card to the same firmware level as the active card. Check with the HP web site
for supported versions.
swDir:admin> slotShow
Slot card Type ID Status
---------------------------------
1 SW card 17 ENABLED
2 SW card 17 ENABLED
3 SW card 17 ENABLED
4 SW card 17 ENABLED
5 CP card 16 ENABLED
6 CP card 16 ENABLED
7 SW card 17 ENABLED
8 SW card 17 ENABLED
9 SW card 17 ENABLED
10 SW card 17 ENABLED
swDir:admin>
swDir:admin> firmwareShow
Local CP (Slot 6, CP1): Active
Primary partition: v5.2.0
Secondary Partition: v5.2.0
Remote CP (Slot 5, CP0): Standby
Primary partition: v5.2.0
Secondary Partition: v5.2.0
Note: If Local CP and Remote CP have different versions
of firmware, please retry firmwaredownload command.
swDir:admin>