HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)

Installing the optional B-Series iSCSI Director Blade146
will autolevel with the firmware version on the active CP. It is critical that the FC4-16IP blade
operates with Fabric OS 5.2.1b or higher, or a fault occurs.
5. Verify that the blade power and blade status LEDs are green after the blade has completed
booting up.
Cabling the FC4-16IP Blade
To complete the switch configuration:
1. Install the SFP transceivers in the Fibre Channel, as required.
a. Remove the rubber plugs from the ports to be used.
b. Position a transceiver so that it is oriented correctly and insert it into a port until it is firmly
seated and the latching mechanism clicks.
For instructions specific to the type of transceiver, see the transceiver manufacturer’s
documentation.
NOTE: The transceivers are keyed to ensure correct orientation. If a transceiver does not install
easily, ensure that it is correctly oriented.
c. Repeat Steps 1a and 1b for the remaining ports, as required.
2. Connect the cables to the transceivers for FC ports or directly into the RJ-45 connections for iSCSI
ports.
CAUTION: A 50-micron cable should not be bent to a radius less than 2 inches under full tensile
load and 1.2 inches with no tensile load. Tie wraps are not recommended for optical cables
because they are easily overtightened.
B
a. Orient a cable connector so that the key (the ridge on one side of connector) aligns with the
slot in the transceiver. Then, insert the cable into the transceiver until the latching mechanism
clicks. For instructions specific to cable type, see the cable manufacturer’s documentation.
b. Repeat Step 2a for the remaining cables as required.
3. Check the port LEDs to verify that all components are functional. For information about LED
patterns, see ”Port blade LED meanings” on page 78.
4. Log in to the 4/256 SAN Director as admin.