HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
SAN Director installation guide 147
5. Verify the correct operation of the FC4-16IP blade ports by typing the switchShow command
from the 4/256 SAN Director command prompt. This command provides information about
switch and port status.
Recommendations for cable management
Cables can be organized and managed in a variety of ways, such as by using cable channels or
patch panels, as follows:
• Plan cable management before installing the blade.
• Leave at least one meter of slack for each port cable. This provides room to remove and replace
the blades, and helps prevent the cables from being bent to less than the minimum bend radius.
sw48000:admin> switchshow
switchName: sw48000
switchType: 42.2
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 15
switchId: fffc0f
switchWwn: 10:00:00:60:69:80:47:74
AD Feature: Active
Current AD: 0
zoning: ON (SIMPLE_CFG)
switchBeacon: OFF
blade1 Beacon: OFF
blade2 Beacon: OFF
blade3 Beacon: OFF
blade7 Beacon: OFF
blade9 Beacon: OFF
blade10 Beacon: OFF
Index Slot Port Address Media Speed State Proto
===================================================
112 10 0 0f7000 id N4 No_Light Disabled (Persistent)
113 10 1 0f7100 -- N4 No_Module Disabled (Persistent)
114 10 2 0f7200 -- N4 No_Module Disabled (Persistent)
115 10 3 0f7300 -- N4 No_Module Disabled (Persistent)
116 10 4 0f7400 -- N4 No_Module Disabled (Persistent)
117 10 5 0f7500 -- N4 No_Module Disabled (Persistent)
118 10 6 0f7600 -- N4 No_Module Disabled (Persistent)
119 10 7 0f7700 id N4 No_Light Disabled (Persistent)
10 ge0 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge1 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge2 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge3 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge4 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge5 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge6 -- 1G No_Sync ISCSI Disabled (Persistent)
10 ge7 -- 1G No_Sync ISCSI Disabled (Persistent)
sw48000:admin>