SAN Director installation guide 163
“Factory Serial Num” and “Serial Num” are listed under “Chassis/WWN Unit 1.” If the current
WWN card is the original card, the factory serial number listed is the same as the chassis serial
number provided on the bar code sticker inside the door of the chassis. If a “Serial Num” value
displays, contact HP to determine whether this serial number should be modified after the new
WWN card is installed.
7. Create a SAN “profile” by entering and recording the information provided by the following
commands:
nsShow
nsAllShow
switchShow
fabricShow
swDir:admin> chassisshow
Chassis Backplane Revision: 1F
SW BLADE Slot: 1
Header Version: 2
Power Consume Factor: -50
Factory Part Num: 60-0001532-03
Factory Serial Num: KP000000195
Manufacture: Day: 1 Month: 1 Year: 2000
Update: Day: 14 Month: 3 Year: 2005
Time Alive: 187 days
Time Awake: 3 days
<output truncated>
CHASSIS/WWN Unit: 1 (in same assembly as WWN Unit: 2)
Header Version: 2
Power Consume Factor: -3
Factory Part Num: 60-0001501-07
Factory Serial Num: FT02X805BE2
Manufacture: Day: 26 Month: 3 Year: 2003
Update: Day: 14 Month: 3 Year: 2005
Time Alive: 207 days
Time Awake: 3 days
<output truncated>