HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)

SAN Director installation guide 171
d. Verify that the command shows the correct serial numbers.
3. Verify that the chassis serial number has been entered correctly by typing chassisShow at the
prompt.
Verify correct operation of system
To verify that the 4/256 SAN Director is operating correctly:
1. Log in to the 4/256 SAN Director as admin:
2. Type slotShow command and verify that all the installed cards are detected and that their
status is operational (enabled).
swDir:root> fruinfoset chassis 1
ID: (none) >
PN: (none) >
SN: (none) > OEMssn12345
RV: (none) >
Chassis SN: (none) > FT00X8008A4
New FRU Info for: chassis(wwn) 1
ID: none
PN: none
SN: OEMssn12345
RV: none
Chassis SN: FT00X8008A4
swDir:root>
swDir:root> login
login: admin
password: xxxxxxxx
swDir:admin>
swDir:admin> slotshow
Slot Blade Type ID Status
---------------------------------
1 AP BLADE 24 ENABLED
2 SW BLADE 18 ENABLED
3 SW BLADE 36 ENABLED
4 AP BLADE 24 ENABLED
5 CP BLADE 16 ENABLED
6 CP BLADE 16 ENABLED
7 SW BLADE 18 ENABLED
8 SW BLADE 36 ENABLED
9 SW BLADE 36 ENABLED
10 AP BLADE 31 ENABLED
swDir:admin>