Replacing the chassis172
3. Verify that the 4/256 SAN Director is functioning correctly by typing switchShow or
switchStatusShow.
This switchShow command displays switch and port status information.
4. Verify that all the IP address information is correct by typing ipAddrShow and checking the
results against the IP information recorded in the config-miscinfo.txt” file.
swDir:admin> switchshow
switchName: swDir
switchType: 42.0
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 2
switchId: fffc02
switchWwn: 10:00:00:60:69:80:5b:e2
zoning: ON (c3)
switchBeacon: OFF
blade1 Beacon: OFF
blade3 Beacon: OFF
blade9 Beacon: OFF
Area Slot Port Media Speed State
=====================================
1 1 0 id N4 Online F-Port 10:00:00:00:c9:29:0e:77
<output truncated>
swDir:admin>
swDir:admin> ipaddrshow
SWITCH
Ethernet IP Address: 10.32.50.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
CP0
Ethernet IP Address: 10.32.50.10
Ethernet Subnetmask: 255.55.0.0
HostName : cp0
Gateway Address: 10.32.40.1
CP1
Ethernet IP Address: 10.32.50.11
Ethernet Subnetmask: 255.55.0.0
HostName : cp1
Gateway Address: 10.32.40.1
Backplane IP address of CP0 : 10.0.0.5
Backplane IP address of CP1 : 10.0.0.6
swDir:admin>swDir:admin>