HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)

SAN Director installation guide 199
Power cords
For each of these types of power cords (see Table 51), the end that connects to the 4/256 SAN
Director chassis has an IEC 60320/C19 cable connector. The two AC power receptacles on each
4/256 SAN Director chassis are equipped with IEC 60320/C20 power connectors.
To order a power cord, contact HP.
NOTE: Regulatory compliance might not be complete for some countries listed (refer to ”Regulatory
compliance” on page 223 for additional information).
AC inrush current 40A maximum, peak
Ride through The supply outputs remain within specified regulation for a minimum of 20
msec after the AC mains are disconnected.
Under voltage protection The 4/256 SAN Director power supply self-protects from any input voltage,
static or dynamic, from zero volts to its operating ranges. It recovers to
normal operation upon returning to its operating range.
Table 50 Power specifications (continued)
Specification Value
Table 51 Power cord types (international)
Country
Receptacle style
NEMA L6-20
USA, Canada,
Mexico, other
North American
locations
CEE-7/7
“Schuko”
Continental
Europe/Ireland
BS-1363A
United
Kingdom/
Hong Kong
AS 3112
Australia/New
Zealand
IEC-60309
16A-6h, 230
V~
Argentina X
Australia X