HP StorageWorks SAN Director Installation Guide (A7393-90009, May 2007)
Port blade and CP card support notes212
CP card compatibility
Installed CP cards determine the Director type:
• If CP1 blades are installed, the Director is an HP StorageWorks Core Switch 2/64.
• If CP2 blades are installed, the Director is a HP StorageWorks SAN Director 2/128.
• If CP4 blades are installed, the Director is a HP StorageWorks 4/256 SAN Director.
NOTE: Mixed CP cards are not supported on a single chassis. HP requires that each CP (primary
and secondary partition) maintain the same firmware version.
Table 58 provides a list of all configurations and port blades supported by the CP cards.
Table 58 CPs and chassisConfig mode
CP Type chassisConfig Mode Number of
Domains
Supported Port Blades
CP1 chassisConfig is not
supported.
2FC-16
CP2 chassisConfig 1 1 FC2-16
FC4-16
chassisConfig 2 2 FC2-16
chassisConfig 3 This chassisConfig mode is no longer
supported.
chassisConfig 4 This chassisConfig mode is no longer
supported.
CP4 chassisConfig 1 1 FC2-16
FC4-16
chassisConfig 5 1 FC4-16
FC4-32
FC4-48
FR4-18i (up to two)
FC4-16IP (up to four)
Note: Up to a maximum of four
AP blades (FR4-18i, FC4-16IP)