Brocade Fabric OS Documentation Updates - Supporting Fabric OS v6.4.x (53-1002063-09, August 2012)

Fabric OS Documentation Updates 43
53-1002063-09
EA DRAFT: BROCADE CONFIDENTIAL
Chapter
6
Fabric OS Message Reference
In this chapter
Replace and update the chapters as described in the following sections:
Documentation updates for Fabric OS v6.4.0 and later. . . . . . . . . . . . . . . . 43
Chapter 12, CDR System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Chapter 31, FCOE System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Chapter 57, KAC System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Documentation updates for Fabric OS v6.4.0 and later
The updates in this chapter are for the Fabric OS Message Reference Supporting Fabric OS v6.4.0
(53-1001767-01), originally published in March 2010.
NOTE
The updates are arranged by the chapter names as they appear in the original document.
Chapter 12, CDR System Messages
Include the following messages in the chapter, CDR System Messages on page 88.
CDR-1007
Message <timestamp>, [CDR-1007], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: Internal link errors have been reported, no hardware faults
identified, continuing to monitor for errors: flt1:<fault1_cnt>,
flt2:<fault2_cnt> thresh1:0x<threshold_used>.
Probable Cause Indicates some errors found in hardware that may or may not impact data traffic.
Recommended
Action
No action is required.
Severity WARNING
CDR-1008
Message <timestamp>, [CDR-1008], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip warning Level 1 type = 0x<chip error type>.