Brocade Fabric OS Documentation Updates - Supporting Fabric OS v6.4.x (53-1002063-09, August 2012)

44 Fabric OS Documentation Updates
53-1002063-09
CDR-1009
6
EA DRAFT: BROCADE CONFIDENTIAL
Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic.
Recommended
Action
Whenever this error occurs, restart the system at the next maintenance window.
Severity WARNING
CDR-1009
Message <timestamp>, [CDR-1009], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip warning Level 2 type = 0x<chip error type>.
Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic.
Recommended
Action
Whenever this error occurs, restart the system at the next maintenance window.
Severity WARNING
CDR-1010
Message <timestamp>, [CDR-1010], <sequence-number>,, CRITICAL, <system-name>, S<slot
number>,C<chip index>: Internal monitoring of faults has identified suspect
hardware, blade may need to be reset or replaced: fault1:<fault1_cnt>,
fault2:<fault2_cnt> thresh2:0x<threshold_used>.
Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic.
Recommended
Action
Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists,
replace the blade.
Severity CRITICAL
Chapter 31, FCOE System Messages
Include the following message in the chapter, FCOE System Messages on page 205.
FCOE-1020
Message <timestamp>, [FCOE-1020], <sequence-number>,, INFO, <system-name>, Login rejected
by FC stack.
Probable Cause Indicates a FLOGI was sent to the FC stack by the FCoE driver but login was rejected by FC stack.
Recommended
Action
No action is required.