DCFM Enterprise User Manual (53-1001775-01, June 2010)

428 DCFM Enterprise User Manual
53-1001775-01
Link aggregation groups
17
3. Click Add LAG.
The Add LAG dialog box displays.
FIGURE 175 Add LAG dialog box
4. Configure the following LAG parameters:
NOTE
Ports with 802.1x authentication or ports that are L2 or L3 mode-enabled are not supported in
a LAG.
Status - Enabled or Disabled. You must enable the LAG to use the CEE functionality.
LAG ID - Enter the LAG identifier, using a value between 1-63. Duplicate LAG IDs are not
allowed.
Interface mode - none or L2.
The L3 interface mode option is displayed in the Edit LAG dialog box only.
L2 interface mode - Select the L2 mode (Access or Trunk):
Access mode allows only one VLAN and allows only untagged frames.
Trunk mode allows more than one VLAN association and allows tagged frames.
A converged mode interface can be native (Access, untagged frames) in one VLAN and
non-native (Trunk, tagged frames) in another VLAN.
IP/Netmask - The netmask is used to divide an IP address into subnets. It specifies which
portion of the IP address represents the network and which portion represents the host,
and can only be configured if the interface mode is L3.
Primary - The primary IP address assigned to a 10 Gbps CEE/FC switch module.
Secondary - The secondary IP address is optional. Secondary IP addresses are helpful
when the interface port is part of multiple subnets.