Support Saves may take a long time with large databases
As databases grow larger from Event, sFlow, and Performance Collector data, the support save
operation may take a long time to run. Larger databases promote longer support save operations.
Make sure you have a minimum of 20–GB disk space for support save and backup operations.
Table 5 Performance Counter calculation formulas
FormulaSource valueProtocol
used
TypeCounter Name
TX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.3.94.4.5.1.6SNMPFCTX
RX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.3.94.4.5.1.7SNMPFCRX
TX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.10SNMPGETX
RX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.6SNMPGERX
TX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.10SNMPFCIPTX
RX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
.1.3.6.1.2.1.31.1.1.1.6SNMPFCIPRX
TX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
PortRX (variable from the return
html file)
HTTPEE
Monitors
TX
RX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
PortTX (variable from the return
html file)
HTTPEE
Monitors
RX
TX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
N/AHCM APIHBA, CNATX
RX = (Delta value1 / (1000 * 1000)) /
(Polling interval2/1000)
N/AHCM APIHBA, CNARX
TX = (Delta value1 / 1000) / (1000 *
1000)
. 1.3.6.1.2.1.2.2.1.11 +
.1.3.6.1.2.1.31.1.1.1.2 +
.1.3.6.1.2.1.31.1.1.1.3
SNMPTETX
RX = (Delta value1 / 1000) / (1000 *
1000)
. 1.3.6.1.2.1.2.2.1.17 +
.1.3.6.1.2.1.31.1.1.1.4 +
.1.3.6.1.2.1.31.1.1.1.5
SNMPTERX
TX% or RX% = ((TX or RX) / ((105000000
* port speed)*( Polling interval2/
N/AN/AFC, GE,
FCIP, HBA,
CNA
TX% / RX%
1000.00))) * 100 If Utilization is less than
1 then the value is it to 0.0
value = (TX or RX) / 10; TX% or RX% =
((value) / ((105000000 * port speed)*(
N/AN/ATETX% / RX%
1000/ 1000.00))) * 100 if Utilization is
less than 1 then the value is it to 0.0
Compression Ratio = current value/ 1000
Since for compression ratio we will take
the current compression ratio value
.1.3.6.1.4.1.1588.4.1.1.4N/AFCIPCompression
Ratio
Receive EOF = Delta value1 / (1000 *
1000)
.1.3.6.1.2.1.16.1.1.1.5N/ATEReceive EOF
Other counters = Delta value
1
N/AN/AN/AOther Counters
1. Delta value is the difference of value retrieved between the two consecutive poling cycles.
2. Polling interval duration between the two polling cycle
Migration and upgrades 13