HP B-series Network Advisor Enterprise, Professional Plus, and Professional 11.1.5 Release Notes (5697-2464, January 2013)

Enumeration issue with HP StorageWorks 2408 FCoE Converged Network Switch running on
Fabric OS 6.3.x or lower
When Network Advisor manages an HP StorageWorks 2408 FCoE Converged Network Switch
running Fabric OS 6.3.x or earlier, connected to an FDMI enabled CNA, enumeration instance
fails for the following classes:
Brocade_EthernetPortLANEndPoint
Brocade_EthernetAdminDomainHostedLanEndPoint
Brocade_EndpointOfNetworkPipe Brocade_LANEndpoint
Brocade_EthernetSwitchHostedLANEndPoint
Brocade_InEthernetLogicalNetwork
Brocade_PlatformHostedLANEndPoint
Instance class key property with special character
Getinstance operation fails if the key property value contains either a semicolon or a
non-printable character.
FC port type value for imported HBAs
Brocade_topologyview.AntecedentFCPortType property value corresponding to the
imported HBA is shown as L_Port.
Migration Issue
Properties configured in the SMI Agent Configuration Tool do not migrate from DCFM 10.4.0
(Solaris) to DCFM 10.4.0 (Windows) through the Copy Data and Settings screen when migrating
from DCFM 10.4.0 (Solaris) to DCFM 10.4.0 (Windows) to Network Advisor 11.1.0 (Windows).
Documentation Updates
For the most recent Network Advisor documentation, visit the following HP website: http://
h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html.
Under Support, select HP Support & Documents, and then select Manuals.
HP Network Advisor 11.1.0 fixes
Table 7 (page 18) lists the closed defects for this release.
Table 7 HP Network Advisor 11.1.0 closed defects
SolutionClosed fixes summary
Fixed in HP Network Advisor 11.1.0.Brocade Access Gateway (AG) switches running Fabric OS 5.3 were not
shown in DCFM and an inappropriate message was shown when trying to
rediscover the fabric.
Fixed in HP Network Advisor 11.1.0.Master log reports port number and port index as one greater than actual
value.
Fixed in HP Network Advisor 11.1.0.DCFM server runs out of memory when managing HP StorageWorks SAN
Director 2/128 or HP StorageWorks 4/256 SAN Director switches for
several weeks.
Fixed in HP Network Advisor 11.1.0.Server backup fails to authenticate with Network drive after a server reboot.
Fixed in HP Network Advisor 11.1.0.The twelfth character of a LUN Serial Number (LSN) is getting dropped on
some paths in the Encryption Disk LUN View.
Fixed in HP Network Advisor 11.1.0.Master Trunk ports in product tree and connections between AG and a
switch are not shown properly when F_Port trunking is enabled on the AG
setup.