HP StorageWorks Fabric OS 6.2 administrator guide (5697-0016, May 2009)

Fabric OS 6.2 administrator guide 207
The following example validates the member list of Admin Domain 10 in the current transaction buffer.
switch:AD255:admin> ad --validate 10 –m 0
Current AD Number: 255 AD Name: AD255
Transaction buffer configuration:
---------------------------------
AD Number: 2 AD Name: ad2 State: Active
Switch port members: 1,1; 1,3; 2,5+; 3,6;
----------------------------
* - Member does not exist
+ - Member is AD Unaware
SAN management with Admin Domains
This section is for users and administrators and describes how you use Admin Domains. If you are a
physical fabric administrator and you want to create, modify, or otherwise manage Admin Domains, see
Admin Domain management for physical fabric administrators” on page 199.
The Admin Domain looks like a virtual switch or fabric to a user. However, based on the user role and type
(User_ID), users are presented with only their relevant AD-based views (see Figure 20 on page 192 and
Figure 21 on page 192). Any devices and switch ports that are not defined as part of the Admin Domain
are not shown and are not available to that AD user.
Each Admin Domain can also have its own zone configurations (defined and effective) with zones and
aliases under them.
CLI commands in an AD context
The CLI command input arguments are validated against the AD member list; they do not work with input
arguments that specify resources that are not members of the current Admin Domain. All commands
present filtered output, showing only the members of the current Admin Domain.
For example, switchShow displays details for the list of AD members present in that switch. Note the
following about the switchShow output:
Because all E_Ports and EX_Ports are shared across all Admin Domains, they are shown under all
Admin Domains.
Other ports are displayed without any attribute details (with an explanation that they are not part of the
current Admin Domain).
A port or device appears in CLI command output or other management tool outputs if any one of the
conditions listed in Table 52 is met.
RASLog and SYSlog output is not filtered based on AD membership.
See the Fabric OS Command Reference for more detailed information about command syntax and usage
and to understand how existing commands behave in an AD context.
Table 52 Ports and devices in CLI output
For Condition
domain,index The port is specified in the domain,index member list of the Admin
Domain.
One or more WWNs specified in the AD member list is attached to the
domain,index.
Device WWN The device WWN is specified in the AD WWN member list.
The device WWN is attached to one of the domain,index specified in the
AD member list.